GB/T 25092-2010Dry-type air-core smoothing reactors for HVDC applications (English PDF)
高压直流输电用干式空心平波电抗器
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25092-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 2, 2010
Implementation date
February 1, 2011
Scope
GB/T 25092-2010 is the English-translated version of 高压直流输电用干式空心平波电抗器.
GB/T 25092-2010 is the Chinese standard "Dry-type air-core smoothing reactors for HVDC applications".
Its scope clause reads: This standard specifies the ± 800kV DC transmission systems and below Dry Hollow smoothing reactors terms and definitions, symbols and names, General requirements for the use of conditions related to design, test, and variation applications, ratings, tolerance, insulation level, dry corona voltage and radio Interference voltage, temperature, sound level test, nameplate, lifting, logo, packaging, transportation and storage, and gives some specific products in Appendix A Examples of relevant performance parameters.
This standard applies to ± 800kV DC transmission systems and below Dry Hollow smoothing reactor (hereinafter referred to as smoothing reactors). Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 25092-2010
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbol and name
- 6 about the design, testing, and application of the deviation of the general requirements
- 7 ratings
- 8 Tolerance
- 9 insulation level
- 10 corona voltage and radio interference voltage
- 11 rise
- 12 sound level
- 13 Test
- 14 Nameplate
- 15 lifting, logo, packaging, transportation and storage
1 Scope
This standard specifies the ± 800kV DC transmission systems and below Dry Hollow smoothing reactors terms and definitions, symbols and names,
General requirements for the use of conditions related to design, test, and variation applications, ratings, tolerance, insulation level, dry corona voltage and radio
Interference voltage, temperature, sound level test, nameplate, lifting, logo, packaging, transportation and storage, and gives some specific products in Appendix A
Examples of relevant performance parameters.
This standard applies to ± 800kV DC transmission systems and below Dry Hollow smoothing reactor (hereinafter referred to as smoothing reactors).
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 775.2 Test method for insulators - Part 2. Electrical test methods
GB 1094.1 Power transformers - Part 1. General (GB 1094.1-1996, eqv IEC 60076-1.1993)
GB 1094.2 Power transformers - Part 2. Temperature Rise (GB 1094.2-1996, eqv IEC 60076-2.1993)
GB/T 1094.4 Power transformers - Part 4. Power transformers and reactors lightning impulse and switching impulse testing guidelines (GB/T 1094.4-2005, IEC 60076-4.2002, MOD)
GB/T 1094.10 Power transformers - Part 10. Determination of sound levels (GB/T 1094.10-2003, IEC 60076-10.2001,
MOD)
Part 11 GB 1094.11 Power transformers. dry-type transformers (GB 1094.11-2007, IEC 60076-11.2004,
MOD)
GB/T 11604 high-voltage electrical equipment radio interference measuring method (eqvCISPR18-1. 1982, CISPR-2. 1986)
GB 50260 Code for seismic design of power facilities
JB/T 5895 Guidelines for the Use dirty areas insulator (JB/T 5895-1991, neqIEC 60815. 1986)
IEC 60076-6.2007 Power transformers - Part 6. Reactors
3 Terms and Definitions
In addition to the following terms and definitions outside, GB 1094.1 and IEC 60076-6.2007 terms and definitions also apply to this standard.
3.1 Rated inductance
Inductor predetermined value.
Note. due to various conditions and the system will require a large capacity smoothing reactor design to more than one series or parallel operation, the rated inductance refers to a single flat
Inductance provisions Reactor values.
3.2 Rated DC voltage
Udr
DC voltage is applied between the predetermined value smoothing reactor line terminal and earth.
GB/T 19212.5-2025 | GB/T 10228-2023 | GB/T 8286-2017 | GB/T 25438-2026 | GB/T 20840.1-2026 | GB/T 25082-2010 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 25092-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 25092-2010
$355.00