Scope
GB/T 1094.11-2022 is the English-translated version of 电力变压器 第11部分:干式变压器.
GB/T 1094.11-2022 — This part of GB 1094 applies to dry-type power transformers (including autotransformers), where the maximum voltage of the equipment is 40.5 kV and below, AND at least one winding is operated at a temperature higher than 1.1 kV. This part applies to dry-type transformers of various structures and processes. This part does not apply to. - Inflatable dry-type transformer (when the inflatable gas is not air); - Single-phase transformer, which has a rated capacity of less than 5 kVA; - Multi-phase transformer, which has a rated capacity of less than 15 kVA; - Transducer; - Starting transformer; - Test transformer; - Locomotive traction transformer; - Flameproof and mining transformers; - Welding transformer; - Voltage regulating transformer; - Small power transformers that focus on safety. When the above-mentioned transformers or other special transformers do not have corresponding standards, this part can be applied in whole or in part.
Found what you need?
Document preview — GB/T 1094.11-2022
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K41
Issued by: State Administration for Market Regulation; Standardization Administration of China
Contents
- Foreword...6
- 1 Scope...9
- 2 Normative references...9
- 3 Terms and definitions...10
- 4 Operating conditions...11
- 4.1 Overview...11
- 4.2 Normal conditions of use...11
- 4.3 Electromagnetic compatibility (EMC)...12
- 4.4 Special conditions of use...12
- 4.5 Transportation and storage conditions...13
- 5 Taps...14
- 6 Binding group...14
- 7 Capability to withstand short circuits...14
- 8 Rated value...14
- 8.1 Overview...14
- 8.2 Rated capacity...14
- 8.3 Priority value of rated capacity...15
- 8.4 Operation above rated voltage...15
- 8.5 Operation during fan cooling...15
- 8.6 Operation in the enclosure...15
- 9 Nameplate...16
- 9.1 Nameplate fixed on the transformer...16
- 9.2 Nameplate fixed on the transformer enclosure...17
- 10 Signs of cooling method...17
- 10.1 Code of signs...17
- 10.2 Arrangement of letter codes...17
- 11 Limit of temperature rise...18
- 11.1 Limit of normal temperature rise...18
Foreword
Chapter 1, Chapter 2, Chapter 3, Chapter 6, Chapter 33, Chapter 34 of this
part are recommended. The rest are mandatory.
GB 1094 "Power transformers" currently contains the following parts.
- Part 1.General;
-Part 2.Temperature rise;
- Part 3.Insulation levels, dielectric tests and external clearances in air;
- Part 4.Guide to the lightning impulse and switching impulse testing - Power
transformers and reactors;
- Part 5.Ability to withstand short circuit;
- Part 10.Determination of sound;
- Part 11.Dry-type transformers.
This part is Part 11 of GB 1094.The number of the previous version of this part
is GB 6450.The corresponding IEC standard number is IEC 60726.As the
standard numbers of IEC related power transformers are now adjusted to the
IEC 60076 series, in order to be in harmony with the IEC standard numbers
AND convenient to use, this revision also adjusts the standard numbers, based
on the new IEC standard series.
This part modifies and adopts IEC 60076-11.2004 "Power transformer - Part 11.
Dry-type transformer" (English version).
This part is redrafted in accordance with IEC 60076-11.2004 in accordance with
the redrafting principles. The numbering of the figure in this part is completely
consistent with IEC 60076-11.2004, whilst the numbering of some chapters,
clauses, tables are not completely consistent with IEC 60076-11.2004.The
comparison list is given in Appendix A.
Taking into account the current conditions of China, when adopting IEC 60076-
11.2004, some technical content has been modified in this part. The differences
have been incorporated into the main text AND marked with a vertical single
line in the margins of the clauses they involve. A list of these technical
differences and their reasons is given in Appendix B, for reference.
For ease of use, this part also makes the following editorial changes to IEC
60076-11.2004.
a) DELETE the forewords of IEC 60076-11.2004;
b) USE a decimal point ".", to replace the comma "," which was used as a
decimal point;
c) According to GB/T 1.1-2000 "Directives for standardization-Part 1.Rules
for the structure and drafting of standards", MODIFY the format of Table 1
in IEC 60076-11.2004.
This part replaces GB 6450-1986 "Dry-type power transformer".
Compared with GB 6450-1986, the main changes in this part are as follows.
- ADD the "Normative references";
- CANCEL the definitions of "dry-type transformers with encapsulated coils",
"dry-type transformers with non-encapsulated coils", "sealed dry-type
transformers";
- ADD some "conditions of use"; ADD "transportation and storage conditions";
- MODIFY the relevant provisions on the correction of temperature rise limit
and insulation level of transformers, which are used for special conditions
of use;
- MODIFY the rated short-time applied withstand voltage of the transformer,
which has a nominal system voltage of 10 kV;
- ADD the technical requirements, test items, test methods for "climate,
environment, combustion performance level";
- MODIFY the relevant technical requirements and test methods of "partial
discharge measurement";
- MODIFY the relevant requirements of the "temperature rise test";
- ADD the requirements for "protection against direct contact", "grounding
terminal", "installation and safety information".
Appendix A, Appendix B, Appendix C, Appendix D of this part are all informative
appendixes.
This part was proposed by the China Electrical Equipment Industry Association.
This part shall be under the jurisdiction of the National Transformer
Standardization Technical Committee (SAC/TC 44).
Drafting organizations of this part. Shenyang Transformer Research Institute,
Power transformers - Part 11.Dry-type transformers
1 Scope
This part of GB 1094 applies to dry-type power transformers (including
autotransformers), where the maximum voltage of the equipment is 40.5 kV and
below, AND at least one winding is operated at a temperature higher than 1.1
kV. This part applies to dry-type transformers of various structures and
processes.
This part does not apply to.
- Inflatable dry-type transformer (when the inflatable gas is not air);
- Single-phase transformer, which has a rated capacity of less than 5 kVA;
- Multi-phase transformer, which has a rated capacity of less than 15 kVA;
- Transducer;
- Starting transformer;
- Test transformer;
- Locomotive traction transformer;
- Flameproof and mining transformers;
- Welding transformer;
- Voltage regulating transformer;
- Small power transformers that focus on safety.
When the above-mentioned transformers or other special transformers do not
have corresponding standards, this part can be applied in whole or in part.
2 Normative references
The provisions in following documents become the provisions of this part
through reference in GB 1094.For the dated references, the subsequent
amendments (excluding corrections) or revisions do not apply to this part;
however, parties who reach an agreement based on this part are encouraged
to study if the latest versions of these documents are applicable. For undated
references, the latest edition of the referenced document applies.
GB 311.1 Insulation co-ordination for high voltage transmission and
distribution equipment (GB 311.1-1997, neq IEC 60071-1.1993)
GB 1094.1 Power transformers - Part 1.General (GB 1094.1-1996, eqv IEC
60076-1.1993)
GB 1094.2 Power transformers - Part 2.Temperature rise (GB 1094.2-1996,
eqv IEC 60076-2.1993)
GB 1094.3 Power transformers - Part 3.Insulation levels, dielectric tests and
external clearances in air (GB 1094.3-2003, IEC 60076-3.2000, MOD)
GB 1094.5 Power transformers - Part 5.Ability to withstand short circuit (GB
1094.5-2003, IEC 60076-5.2000, MOD)
GB/T 1094.10 Power transformers - Part 10.Determination of sound (GB/T
1094.10-2003, IEC 60076-10.2001, MOD)
GB/T 2900.15 Electrotechnical terminology - Transformer, instrument
transformer, voltage regulator and reactor (GB/T 2900.15-1997, neq IEC
60050-421.1990, IEC 60050-321.1986)
GB 4208 Degrees of protection provided by enclosure (IP code) (GB 4208-
1993, eqv IEC 60529.1989)
GB/T 7354 Partial discharge measurements (GB/T 7354-2003, IEC
60270.2000, IDT)
GB/T 11021 Thermal evaluation and classification of electrical insulation
(GB/T 11021-1989, eqv IEC 60085.1984)
GB/T 17211-1998 Loading guide for dry-type power transformers (eqv IEC
60905.1987)
GB/T 17467 High-voltage/low-voltage prefabricated substations (GB/T
17467-1998, eqv IEC 61330.1995)
GB/T 18380.3 Tests on electric cables under fire conditions - Part 3.Tests
on bunched wires or cables (GB/T 18380.3-2001, idt IEC 60332-3.1992)
3 Terms and definitions
The terms and definitions as defined in GB/T 2900.15, as well as the following
terms and definitions, apply to this part.
temperature rise test.
23.2.1 Simulated load method
This method is suitable for non-enclosed, enclosed or fully enclosed dry-type
self-cooled or air-cooled transformers.
The temperature rise value is determined, by a combination of short-circuit test
(providing load loss) AND no-load test (providing no-load loss).
At the beginning of the test, the temperature of the transformer shall be as
stable as the ambient temperature of the test room. It shall measure the
resistance values of the high and low voltage windings. These measured values
will be used as the reference values, for calculating the temperature rise of the
two windings. The ambient temperature of the test room shall also be measured
and recorded.
For a three-phase transformer, the resistance measurement shall be carried out,
between the middle phase and the wire terminal of one side phase winding.
The position of each temperature measurement point [i.e.. the thermometer for
measuring the ambient temperature AND the sensor on the transformer (if any)],
shall be same, regardless of whether it is a reference measurement or a final
measurement.
The winding's short-circuit test shall be carried out under the condition, that the
rated current flows through one winding, whilst the other winding is short-
circuited; it continues until the temperature of the winding and the core reaches
a steady state, as shown in 23.4.Use resistance method or superposition
method, to determine the temperature rise deltathetac of each winding.
The no-load test, at rated frequency and rated voltage, shall be continued, until
the winding and core temperature reach a steady state. Then it shall measure
the temperature rise deltathetae of the respective windings.
The test procedure for temperature rise shall use one of the following two
methods.
- Perform short-circuit test for the winding first, until the core and winding
temperature reaches a stable level; then perform no-load test, until the
temperature of the core and winding reaches a stable level;
- First carry out the no-load test, until the temperature of the core and winding
reaches a stable level; then carry out a short-circuit test of the winding, until
the temperature of the core and winding reaches a stable level.
When the rated current passes through the winding AND the core is at the rated
test period.
Before and after the test, it shall weigh the mass of the test product; the
weighing accuracy shall be ±0.5% or higher. The iron core post and the coil with
insulating parts can be weighed separately.
28.7 Test report
The test report shall contain the following information.
a) Test results of material samples (if required by the user);
b) Calculated mass, thermal energy value (if possible), measured mass of
sample of combustible materials;
c) The calibration results of the test chamber (air flow, temperature in the
measurement segment, adjustment of the regulating valve or air
extraction system, etc.);
d) A comprehensive description of the test method, including alcohol burning
time and energized heating time;
e) The calculated value of the mass loss of combustible materials (accuracy
of ±10%) AND the heat released (MJ) (if possible), during the test;
f) The temperature record value of the whole test process, from the beginning
of the test (starting when the alcohol is ignited); record it once every 2
minutes or less;
g) The continuous recorded value (%) of the visible light, which is transmitted
in the measurement segment, during the entire test;
h) During the entire test, the air flow (m3/s) in the measurement segment,
which is measured once every 2 minutes or less;
i) The burning state visible on the sample.
28.8 Evaluation criteria for test results
If the test product meets the following requirements, the test is considered
qualified.
a) During the entire test, the temperature rise of the gas in the measurement
segment, in the chimney, to the ambient temperature shall not exceed 420
K;
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1094.10Power transformers - Part 10: Determination of sound levels
- GB/T 7354High-voltage test techniques -- Partial discharge measurements
- GB/T 7354-2003High-voltage test techniques -- Partial discharge measurements
- GB/T 17467High-voltage/low-voltage prefabricated substation
GB 1094 · GB 311.1 · GB 311.1-1997 · IEC 60071 · GB 1094.1 · GB 1094.1-1996 · GB 1094.2 · GB 1094.2-1996 · IEC 60076 · GB 1094.3 · GB 1094.3-2003 · GB 1094.5 · GB/T 2900.15 · GB/T 2900.15-1997 · IEC 60050 · GB 4208 · IEC 60529.1989 · GB/T 11021 · GB/T 11021-1989 · IEC 60085.1984 · GB/T 17211-1998 · IEC 61330.1995 · GB/T 18380.3 · GB/T 18380.3-2001 · IEC 60332
Cited by
- GB/T 36028.1-2025Technical conditions for shore-to-ship power supply systems - Part 1: High voltage connection
- GB/T 36028.2-2025Technical conditions for shore-to-ship power supply systems - Part 2: Low voltage connection
- GB/T 45648.1-2025Controllable self-restoring energy dissipation devices - Part 1: DC side
- GB/T 45648.2-2025Controllable self-restoring energy dissipation devices - Part 2: AC side
- GB 20052-2024Minimum allowable values of energy efficiency and energy efficiency grades for power transformers
- GB/T 32825-2024Technical parameters and requirements for three-phase dry-type tridimensional wound core power transformers
How to Download GB/T 1094.11-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1094.10-2022 — Power transformers - Part 10: Determination of sound levels
GB/T 1094.101-2023 — Power transformers - Part 101: Determination of sound levels - Application guide
GB/T 17467-2020 — High-voltage/low-voltage prefabricated substation
Secure payment via Stripe
Payments accepted
GB/T 1094.11-2022
$700.00