Scope
GB/T 23755-2020 is the English-translated version of 三相组合式电力变压器.
GB/T 23755-2020 is the Chinese standard for three-phase site-combined power transformers.
It gives the terms and definitions, the conditions of use, the product models, the basic parameters, the structural and technical requirements, the nameplate, the allowable deviations, the inspection rules and methods and the provisions on marking, lifting, packaging, transport and storage.
It applies to three-phase combined power transformers of 40 000 kVA and above, for systems of 110 kV to 500 kV at 50 Hz. Transformer makers, grid companies and test laboratories use it.
Issued on 19 November 2020, it has applied since 1 June 2021, replacing GB/T 23755-2009.
Found what you need?
Document preview — GB/T 23755-2020
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
- Replacing
- GB/T 23755-2009
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Conditions of use
- 5 Product model
- 6 Basic parameters
- 7 Structural requirements
- 8 Technical requirements
- 9 Nameplate
- 10 Allowable deviation
- 11 Inspection rules and methods
- 12 Marking, lifting, packaging, transportation, installation and storage
- Reference
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 23755-2009 "Three-phase combined power transformer", compared with GB/T 23755-2009, the main technology The changes are as follows.
---For 110kV and 220kV three-phase combined power transformers, the capacity of 40000kVA and 50000kVA has been increased. Quantity specifications and performance parameters (see 6.1.1 and 6.1.2);
---Added 330kV class three-phase combined power transformer related capacity specifications and performance parameters (see 6.1.3);
---The performance parameters of 110kV, 220kV and 500kV three-phase combined power transformers have been modified, no-load loss And load loss decreased by about 20% and 5% respectively, and the no-load current decreased by about 20% respectively (see 6.1, 2009 Version 6.1);
---Modified the parameter values of voltage and short-circuit impedance in some performance parameter tables (see Table 2~Table 13 and Table 17, 2009 Version Table 2~Table 13 and Table 17);
---The technical requirements have been revised uniformly (see Chapter 7 and Chapter 8, Chapter 7 of the 2009 edition).
1 Scope
This standard stipulates that the rated capacity is 40000kVA and above, the nominal voltage of the system is 110kV~500kV, and the rated frequency is 50Hz three-phase combined power transformer terms and definitions, use conditions, product models, basic parameters, structural requirements, technical requirements, name Licenses, allowable deviations, inspection rules and methods, signs, lifting, packaging, transportation, installation and storage.
This standard applies to oil-immersed three-phase combined power transformers used in substations or power plants with restricted transportation conditions or layout sites. Depressor.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 1094.1 Power Transformer Part 1: General Rules
GB/T 1094.2 Power Transformer Part 2: Temperature Rise of Liquid-immersed Transformer
GB/T 1094.3 Power Transformer Part 3: Insulation Level, Insulation Test and External Insulation Air Gap
GB/T 1094.5 Power Transformer Part 5: Ability to withstand short circuit
GB/T 1094.7 Power Transformer Part 7: Load Guidelines for Oil-immersed Power Transformers
GB/T 1094.10 Power Transformer Part 10: Sound Level Measurement
GB/T 2900.95 Electrotechnical terminology transformer, voltage regulator and reactor
GB/T 6451 Oil-immersed power transformer technical parameters and requirements
JB/T 501 Power Transformer Test Guide
JB/T 3837 Modeling method for transformer products
JB/T 10088 6kV~1000kV power transformer sound level
3 Terms and definitions
The following terms and definitions defined in GB/T 1094.1 and GB/T 2900.95 apply to this document.
3.1 Unit
Contains a single-phase body and fuel tank with an independent magnetic circuit, and can be transported independently.
3.2 Interphase pipeline
Pipes connecting the electrical and oil circuits of the three units.
3.3 Three-phase combined power transformer
A three-phase power transformer that will share one oil conservator and be installed on the same foundation with three units connected through interphase pipelines.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1094.1Power transformers-Part 1: General
- GB/T 1094.3Power transformers -- Part 3: Insulation levels, dielectric tests and external clearances in air
- GB/T 1094.7Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers
- GB/T 1094.10Power transformers - Part 10: Determination of sound levels
- GB/T 2900.95Electrotechnical terminology -- Transformers, voltage regulators and reactors
- GB/T 6451Technical parameters and requirements for oil-immersed power transformers
GB/T 1094.2 · GB/T 1094.5
Similar standards
Editions of GB/T 23755
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 23755-2020 | Three-phase site-combined power transformer | current edition | Current |
| GB/T 23755-2009 | Three-phase site-combined power transformer | previous edition | Superseded |
This page sells the current edition, GB/T 23755-2020. Earlier editions are listed for reference only.
How to Download GB/T 23755-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1094.1-2013 — Power transformers-Part 1: General
GB/T 1094.10-2022 — Power transformers - Part 10: Determination of sound levels
GB/T 1094.101-2023 — Power transformers - Part 101: Determination of sound levels - Application guide
Secure payment via Stripe
Payments accepted
GB/T 23755-2020
$300.00