GB 15208.1-2018Micro-dose X-ray security inspection systems - Part 1: General technical requirements (English PDF)

微剂量X射线安全检查设备 第1部分:通用技术要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB 15208.1-2018 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC

Level / Type

National · Mandatory

Issue date

November 19, 2018

Implementation date

December 1, 2019

Scope

GB 15208.1-2018 is the English-translated version of 微剂量X射线安全检查设备 第1部分:通用技术要求.

GB 15208.1-2018 is Part 1 of the Chinese national standard on micro-dose X-ray security inspection equipment and gives the general technical requirements.

It defines the terms used, among them the equivalent atomic number, the impenetrable area and the material uncertainty area, the single inspection dose, the ambient dose equivalent rate, transmission and backscatter equipment, controlled and supervised areas, the safety interlock and the emergency stop switch.

It classifies equipment by technology, by material discrimination, by shielding and by the object inspected, then sets the limits on single inspection dose, ambient dose equivalent rate and noise, the working environment, equipment and X-ray generator safety, mechanical construction, electromagnetic compatibility, electrical safety and environmental adaptability, with the matching test methods, inspection rules, packaging and marking.

It replaces GB 15208.1-2005, was issued on 19 November 2018 and has applied since 1 December 2019.

Found what you need?

Document preview — GB 15208.1-2018

National Standard of the People's Republic of China

ICS
13.310
Classification
A 91

Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Equipment Category
  • 5 General technical requirements
  • 6 Test method
  • 7 Inspection rules
  • 8 Packaging, labeling, storage and transportation
  • 9 Random technical documents
  • Appendix A (Normative Appendix) Single Test Dose Test Method
  • Appendix B (Normative Appendix) Test Method for Peripheral Equivalent Rate
  • Reference

Foreword

All technical content in this section is mandatory.

GB 15208 "Micro Dose X-ray Safety Inspection Equipment" is divided into the following five parts.

--- Part 1. General technical requirements;

--- Part 2. Transmissive bag security inspection equipment;

--- Part 3. Transmissive cargo safety inspection equipment;

--- Part 4. Human body safety inspection equipment;

--- Part 5. Backscattering items safety inspection equipment.

This part is the first part of GB 15208.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

This part replaces GB 15208.1-2005 "Micro-dose X-ray safety inspection equipment Part 1: General technical requirements", and The main technical changes compared with GB 15208.1-2005 are as follows.

--- Added 8 terms. equivalent atomic number, ambient dose equivalent rate, transmission X-ray safety inspection equipment, backscatter X

Radiation safety inspection equipment, control area, supervision area, open micro-dose X-ray safety inspection equipment, closed micro-dose X-ray

Line safety inspection equipment (see 3.1, 3.8, 3.12, 3.13, 3.16, 3.17, 3.18, 3.19);

--- Revised the names of the five terms (see 3.2, 3.3, 3.4, 3.14, 3.15, 3.11, 3.12, 3.13, 3.22, 3.23 of the 2005 edition);

--- Revised the definition of three terms. single-check dose, micro-dose X-ray safety inspection equipment, safety interlock (see 3.7, 3.11, 3.20, 3.17, 3.21, 3.24 of the 2005 edition);

--- Removed 11 terms (see 3.1, 3.2, 3.3, 3.4, 3.5, 3.6, 3.7, 3.8, 3.9, 3.10, 3.16 in 2005);

--- Added equipment classification (see Chapter 4);

--- Removed performance indicator requirements (see version 4.1 of 2005);

--- Revised radiation and environmental safety indicators (see 5.2, 2005 edition 4.2);

---Modified working environment conditions (see 5.3.1, 4.3.1 of the 2005 edition);

---Modified equipment safety requirements [see 5.4.1e), 5.4.1g), 2005 version 4.4.1e), 4.4.1g)];

---Modified mechanical structure (see 5.5, 2005 version 4.5);

---Modified electromagnetic compatibility requirements (see 5.6, 4.6 of the 2005 edition);

---Modified electrical safety (see 5.7, 5.8, 5.9, 5.10, 4.7 of the 2005 edition);

---Modified environmental adaptability (see 5.11, 4.8 of the 2005 edition);

--- Added functional requirements (see 5.12);

--- Modified the main instruments and tools for testing (see 6.2, 5.2 of 2005 edition);

--- Revised radiation and environmental indicators test (see 6.3, 5.5 of 2005);

--- Modified the power supply scope experiment (see 6.4, 2005 version 5.7);

---Modified security performance test (see 6.5, 5.6 of 2005 edition);

--- Removed the performance indicator test (see 5.4 of 2005 edition);

--- Revised the visual inspection (see 6.6.1, 5.3.1 of the 2005 edition);

--- Modified the electromagnetic compatibility test (see 6.7, 2005 version 5.10);

--- Revised the electrical safety test (see 6.8, 6.9, 6.10, 6.11, 5.9 of the 2005 edition);

---Modified environmental adaptability test (see 6.12, 2005 edition of 5.8);

--- Added functional requirements testing (see 6.13);

--- Removed the evaluation of the test image (see Chapter 6 of the 2005 edition);

--- Added inspection rules (see Chapter 7);

---Modified packaging requirements [see 8.1a), 2005 edition of 8.1a)];

--- Revised the marking requirements (see 8.2, 8.2 of the 2005 edition);

--- Revised the normative appendix (see Appendix A, Appendix B, Appendix A, Appendix B of the 2005 edition);

--- Deleted the informative appendix (see Appendix C of the 2005 edition).

1 Scope

This part of GB 15208 specifies the classification, general technical requirements, test methods and inspection rules for micro-dose X-ray safety inspection equipment. Then, packaging, marking, storage and transportation, and random technical documents.

This section applies to the design, manufacture, acceptance and use of various micro-dose X-ray safety inspection equipment.

This section does not apply to computed tomography (CT), electron accelerators, and X-ray generating devices with energy greater than 500 keV. Radiation safety inspection equipment.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 191-2008 packaging storage and transportation icon

GB/T 2423.1-2008 Environmental testing of electric and electronic products - Part 2: Test methods Test A. Low temperature

GB/T 2423.2-2008 Environmental testing of electrical and electronic products - Part 2: Test methods Test B. High temperature

GB/T 2423.3-2016 Environmental testing - Part 2: Test method test Cab. constant damp heat test

GB/T 2423.5-1995 Environmental testing for electric and electronic products - Part 2: Test methods Test Ea and guide. Impact

GB/T 2423.10-2008 Environmental testing of electric and electronic products - Part 2: Test method test Fc. Vibration (sinusoidal)

GB/T 4208-2017 enclosure protection grade (IP code)

GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory - Part 1: General requirements

GB/T 9254-2008 Radio disturbance limits and methods of measurement for information technology equipment

GB/T 17626.2-2006 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test

GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test

GB/T 17626.4-2008 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test

GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test

GB/T 17626.6-2008 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction

GB/T 17626.11-2008 Electromagnetic compatibility test and measurement techniques Immunity to voltage dips, short interruptions and voltage changes test

GB/T 17799.1-2017 Electromagnetic compatibility common standards Immunity in residential, commercial and light industrial environments

GB/T 17799.2-2003 Electromagnetic compatibility general standard immunity test in industrial environment

GB/T 17799.3-2012 Common standards for electromagnetic compatibility, emissions in residential, commercial and light industrial environments

GB/T 17799.4-2012 Electromagnetic compatibility general standard emission in industrial environment

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Equivalent atomic number

Zeff An atomic number representing the theoretical element of a material property that has the same X-ray attenuation characteristics as this material.

3.2 Equivalent organic matter

A substance with an equivalent atomic number below 10.

3.3 Equivalent inorganic effective inorganic material

A substance with an equivalent atomic number higher than 18.

3.4 Equivalent mixture effective mixed material

A substance whose equivalent atomic number is between 10 and 18.

3.5 Wear impenetrable area

The intensity of X-ray penetration of the object to reach the X-ray detector is almost zero, and the device cannot recognize the basic structural features of the object under test. […]

3.6 Material uncertainty area

Although the ray can penetrate, it is impossible to identify the area of the material property of the object to be inspected.

3.7 Single dose

The subject undergoes an examination to absorb the absorbed kinetic energy of the air.

Note: The single-dose dose unit is Gy, 1Gy=1J/kg.

3.8 Peripheral dose equivalent rate

The quotient of dH *(10) and dt, where dH *(10) is the increment of the surrounding dose equivalent within the time interval dt.

Note: The International System of Units (SI) unit for the surrounding dose equivalent rate is [Watt] per second (Sv/s). The unit of the surrounding dose equivalent rate is [Watt] or its multiple Or the quotient of the score with the appropriate time unit (for example. mSv/h). [GB/T 4835.1-2012, definition 3.3]

3.9 Scatter

An object that scatters radiation to produce the worst radiation conditions.

3.10 X-ray security inspection equipment

X-ray intensity distribution or energy spectrum distribution is measured by the interaction of X-rays with the object to be inspected, and an X-ray image of the object to be inspected is generated.

An apparatus that recognizes the safety of the object to be inspected based on the information of the material to be inspected.

3.11 Micro-dose X-ray safety inspection equipment

A single inspection of X-ray safety inspection equipment with a dose less than or equal to 10 µGy.

3.12 Transmissive micro-dose X-ray safety inspection equipment

Generating an X-ray image of the object to be inspected or providing a detected pair by measuring an X-ray intensity distribution or an energy spectrum distribution passing through the object to be inspected

Like material information, a micro-dose X-ray safety inspection device that identifies the safety of the object to be inspected.

3.13 Backscatter micro-dose X-ray safety inspection equipment

Using the scattering effect of X-ray photons and matter interaction, collecting backscattered X-rays scattered by the object under test and generating a test Micro-dose X-ray safety inspection device for object images.

3.14 Single-energy spectrum micro-dose X-ray safety inspection equipment

Using X-ray interaction with the object to be inspected, measuring the intensity distribution of the X-ray and imaging the structural characteristics of the object to be inspected Micro-dose X-ray safety inspection equipment.

3.15 Multi-energy micro-dose X-ray security inspection system

According to the laws of different equivalent atomic numbers on the absorption characteristics of X-ray energy spectrum, the material properties of the object to be inspected are judged. A micro-dose X-ray safety inspection device that recognizes and images.

3.16 Control area

An area defined in a radiation workplace where special protective measures and safety measures are required or may be required, so that.

a) control normal exposure or prevent contamination expansion under normal operating conditions;

b) Prevent potential exposure or limit its extent. [GB 18871-2002, definition J5.5]

3.17 Supervised area

Anyone who has not been identified as a control area, usually does not need to take special protective measures and safety measures, but must constantly check his occupational exposure conditions What area. [GB 18871-2002, definition J5.6]

3.18 Open micro-dose X-ray safety inspection equipment

Radiation protection devices for shielding, leaking rays, etc. generated during the inspection process are not installed, and it is necessary to delineate the supervision area or place it in compliance.

Radiation protection requires micro-dose X-ray safety inspection equipment at the location.

3.19 Closed micro-dose X-ray safety inspection equipment

Micro-dose X-ray safety inspection with radiation protection devices for shielding scattering, leaking rays, etc. generated during the inspection process device.

3.20 Safety interlocking device

A device that protects the X-ray equipment from working safely and prevents X-rays from being emitted under abnormal conditions. […]

3.21 Emergency stop switch

In an emergency, the components of the power supply of the X-ray generating device and the conveying device can be cut off immediately.

3.22 X-ray generating device

Generate and control a combination of all components of the X-ray emission.

Note: Usually consists of an X-ray tube, a high voltage generator, a controller, and a cooling system.

3.23 X-ray detector

A sensor that detects (measures) X-rays and converts X-ray intensities into electrical signals that can be processed.

3.24 Test body

A test object for testing and evaluating X-ray image performance indicators.

3.25 Test card

A test object used to test and evaluate an indicator of X-ray images.

4 Equipment classification

4.1 Micro-dose X-ray safety inspection equipment (hereinafter referred to as equipment) is divided into. according to technical characteristics.

a) transmissive equipment;

b) backscattering equipment;

c) Transmissive, backscatter combined equipment.

4.2 Equipment is divided according to material resolution.

a) single energy spectrum equipment;

b) Multi-spectral spectrum equipment.

4.3 Equipment is classified according to the type of protection.

a) open equipment; b) Closed equipment.

4.4 The device is divided into the types of objects to be inspected.

a) line-package equipment;

b) cargo equipment;

c) Human body equipment.

5 General technical requirements

5.1 Overview

For combined equipment (eg transmission, backscatter combination), all technical requirements of the respective technology type should be met.

5.2 Radiation and environmental safety indicators

5.2.1 Single dose check

A single inspection dose of a device with only one X-ray generating device should be less than or equal to 5 µGy, and there are multiple X-ray generating devices.

A single check dose should be less than or equal to 10µGy, a device with multiple inspection channels, and a single dose of any one of the channels Should meet the above requirements.

5.2.2 Peripheral dose equivalent rate

When the equipment is working normally, the enclosed equipment is at a distance of 0.1m from any accessible surface of the equipment (including the inlet and outlet of the equipment).

The volume equivalent rate should be less than or equal to 1µSv/h; open equipment needs to be delineated or placed in compliance with radiation protection requirements, outside the supervision area The surrounding dose equivalent rate should be less than or equal to 2.5 µSv/h; the surrounding dose equivalent rate of the worker position should be less than or equal to 0.5 µSv/h.

5.2.3 Equipment noise

The equipment noise should be less than or equal to 65dB (A) at any point 1m away from the outer surface of the equipment during normal operation.

5.3 Operating environment

5.3.1 Working environment conditions

Ambient temperature range. 5 ° C ~ 40 ° C. Relative humidity range. 5%~85%. Atmospheric pressure range. 70kPa~106kPa.

5.3.2 Power Adaptability

The power supply voltage shall be within 10%-15% of the nominal voltage and the nominal frequency ±3Hz, and the equipment shall be able to operate normally.

5.4 Security performance

5.4.1 Equipment Safety

Requirements are as follows.

a) The equipment should have obvious system operation and ray emission display devices (indicators);

b) The equipment should be equipped with an emergency stop switch at a location accessible to the operator. If an emergency occurs, the equipment X can be cut off immediately.

The power supply of the radiation generating device and the conveying device; the emergency stop switch should use a red switch with a yellow bottom;

c) The equipment shall be equipped with a power overcurrent protection device of appropriate rating to prevent overuse of internal components or other accidents. Current may cause a fire hazard;

d) The equipment shall be provided with a key switch and a secondary power start switch, and the key switch shall be able to clearly identify the "on" and "off" positions;

e) A safety protection interlock shall be fitted on the detachable radiation protection component of the X-ray emission area. Once the interlock is disconnected,

The power supply of the X-ray generating device of the device can be cut off immediately, and the X-ray should stop emitting immediately;

f) The equipment should have an operator identification function;

g) The equipment shall display the gray scale of the material uncertainty area and give obvious hints to the impervious area.

5.4.2 X-ray generating device safety

Requirements are as follows.

a) The X-ray generator shall be self-cooled within the equipment;

b) X-ray generators using external circulation cooling systems should have temperature or pressure control when the temperature of the coolant (oil or water) exceeds When the specified value is exceeded or the circulating pressure is lower than the specified value, the X-ray emission can be automatically stopped;

c) The X-ray generating device shall have an overvoltage and overcurrent protection function, which can automatically be used when its voltage or current exceeds the specified value of the product. Cutting off the high pressure;

d) The X-ray generating device shall have a protective grounding wire. The color of the grounding wire shall be yellow-green, and the grounding resistance shall not exceed 0.1 ohm.

5.5 Mechanical structure

Requirements are as follows. […]

5.5.1 Appearance section

Requirements are as follows.

a) The design and operation procedures of the equipment shall be in accordance with the basic requirements of ergonomics and shall be easy to operate and maintain;

b) The appearance of the equipment should be intact, the surface should be smooth and smooth, the color should be uniform, no obvious mechanical damage, no blistering damage to the coating, metal The parts shall be free from rust and the plastic parts shall be free from blistering and cracking;

c) Mark and write on the panel clearly.

5.5.2 Mechanical part

Requirements are as follows.

a) The equipment consists of parts and all parts, and should have sufficient strength and rigidity. All adjustment and control mechanisms should be installed correctly and operated. flexible;

b) The installation and disassembly of the outer cover should be convenient;

c) The frame shall have sufficient strength and rigidity to be free from deformation or damage during normal handling;

d) The equipment casters should have sufficient strength and rotational flexibility, and the connection with the equipment should be firm and reliable;

e) The degree of protection of the enclosure shall comply with the provisions of GB/T 4208-2017 and not less than the requirements of IP20.

5.6 Electromagnetic compatibility

5.6.1 Equipment Immunity

Electrostatic discharge, radio frequency electromagnetic field radiation, electrical fast transient bursts, surge (shock), and RF field induced conduction disturbances And 6 voltage immunity tests for voltage sag, short interruption and voltage change. The immunity performance of equipment working in industrial environment should be consistent.

The requirements for the limits specified in Tables 1, 2 and 4 of GB/T 17799.2-2003. Equipment for working in residential, commercial and light industrial environments The immunity performance shall comply with the requirements specified in Tables 1, 2 and 4 of GB/T 17799.1-2017.

5.6.2 Equipment launch

The radiated and conducted emission values of equipment operating in an industrial environment shall comply with the limits specified in Table 1 of GB/T 17799.4-2012.

The radiated and conducted emission values of equipment operating in residential, commercial and light industrial environments shall be in accordance with Table 1 of GB/T 17799.3-2012 The requirements for the specified limits.

5.7 Anti-shock

The equipment shall be protected against electric shock under normal conditions and single fault conditions, and the accessible parts of the equipment shall not be dangerously charged. Meet the requirements of Chapter 6 of GB 4793.1-2007.

5.8 Anti-mechanical danger

Operation under normal conditions or under single fault conditions shall not cause mechanical hazards and comply with the requirements of Chapter 7 of GB 4793.1-2007.

5.9 Preventing the spread of flame

Under normal conditions or under single fault conditions, the flame shall not spread to the outside of the equipment, in accordance with Chapter 9 of GB 4793.1-2007.

5.10 Temperature limits and heat resistance

The temperature limit and heat resistance of the equipment shall comply with the requirements of Chapter 10 of GB 4793.1-2007.

5.11 Environmental adaptability

5.11.1 Overview

The environmental adaptability of equipment and electrical components with independent functions meets the following requirements.

a) The equipment is a large-scale electromechanical product. When it is not suitable for environmental testing of the whole machine, it is allowed to press the electrical parts with independent functions separately. 5.11.2 and 5.11.5 shall be tested; the technical indicators of the whole machine or electrical component test shall meet the requirements of the equipment or components;

b) Electrical components with independent functions, after testing in 5.11.2 and 5.11.5, connect to the whole machine to test the whole machine, the equipment should be able to normal work;

c) After climatic and mechanical environmental tests, equipment should not show signs of corrosion and mechanical damage.

5.11.2 Climate and environmental adaptability

See Table 1 for requirements.

5.11.3 Resistance to mechanical shock and impact

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

Normative references

GB 4793.1-2007 · GB/T 9254-2008 · GB/T 17799.3-2012 · GB/T 17799.4-2012

Cited by

Similar standards

Editions of GB 15208.1

EditionTitleRevisionStatus
GB 15208.1-2018Micro-dose X-ray security inspection systems - Part 1: General technical requirementssecond revisionCurrent
GB 15208.1-2005Micro-dose X-ray security inspection systems - Part 1: General technical requirementsfirst revisionSuperseded
GB 15208-1994Micro-dose X-ray security inspection systemsfirst issueSuperseded

This page sells the current edition, GB 15208.1-2018. Earlier editions are listed for reference only.

How to Download GB 15208.1-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 15208.1-2018

$240.00