GB/T 4074.3-2008Winding wires -- Test methods -- Part 3: Mechanical properties (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for GB/T 4074.3-2008 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
April 23, 2008
Implementation date
December 1, 2008
Scope
GB/T 4074.3-2008 (Winding wires -- Test methods -- Part 3: Mechanical properties) is available as an English-translated PDF.
GB/T 4074.3-2008 — This Part of GB/T 4074 specifies the following methods of test. - Test method 6.Elongation; - Test method 7.Springiness; - Test method 8.Flexibility and adherence; - Test method 11.Resistance to abrasion; - Test method 18.Heat or solvent bonding.
For definitions, general notes on methods of test and the complete series of methods of test for winding wires, see GB/T 4074.1.
Found what you need?
Document preview — GB/T 4074.3-2008
National Standard of the People's Republic of China
- ICS
- 29.060.01
- Classification
- K 12
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative references...5
- 3 Test method 6.Elongation...6
- 4 Test method 7.Springiness...6
- 5 Test method 8.Flexibility and adherence...9
- 6 Test method 11.Resistance to abrasion (applicable to enamelled round wire)...13
Foreword
GB/T 4074-2008 "Winding wires - Test methods" consists of 8 parts.
- Part 1.General;
- Part 2.Determination of dimensions;
- Part 3.Mechanical properties;
- Part 4.Chemical properties;
- Part 5.Electrical properties;
- Part 6.Thermal properties;
- Part 7.Test procedure for the determination of the temperature index of enamelled
winding wires (under consideration);
- Part 8.Test procedure for the determination of the temperature index of enamelled
winding wires - Quick-Test method (under consideration).
This Part is Part 3 of GB/T 4074.
This Part is identical to IEC 60851-3.1997 "Winding wires - Test methods - Part 3.
Mechanical properties", Edition 2.1 (English version), and amendment No. 2 (2003).
For ease of use, the following editorial changes have been made to this Part.
- REPLACE the comma "," used as a decimal point WITH a decimal point ".".
This Part replaces GB/T 4074.3-1999 from the date of implementation.
Compared with GB/T 4074.3-1999, the main changes in this Part are as follows.
- LIMIT the adherence test of tape wrapped round and rectangular wires in 5.5.4 TO
only applicable to adhesive tape wrapped wire products;
- DELETE the requirements for solvent bonding and the corresponding instructions
and NOTE 1 in GB/T 4074.3-1999 in Test method 18;
- MODIFY Figure 10 "Test equipment for bond retention of a helical coil";
- MODIFY suggestive Annex A and suggestive Annex B TO informative Annex A
and informative Annex B.
Annex A and Annex B of this Part are informative annexes.
This Part was proposed by China Electrical Equipment Industry Association.
Winding wires - Test methods - Part 3.Mechanical
properties
1 Scope
This Part of GB/T 4074 specifies the following methods of test.
- Test method 6.Elongation;
- Test method 7.Springiness;
- Test method 8.Flexibility and adherence;
- Test method 11.Resistance to abrasion;
- Test method 18.Heat or solvent bonding.
For definitions, general notes on methods of test and the complete series of methods of
test for winding wires, see GB/T 4074.1.
2 Normative references
The following documents contain the provisions which, through reference in this Part
of GB/T 4074, become the provisions of this Part. For dated references, their subsequent
amendments (excluding corrigendum) or revisions do not apply to this Part. However,
the parties who enter into agreement based on this Part are encouraged to investigate
whether the latest versions of these documents are applicable. For undated reference
documents, the latest versions apply to this Part.
GB/T 4074.1 Winding wires - Test methods - Part 1.General (GB/T 4074.1-2008,
IEC 60851-1.1996, IDT)
GB/T 4074.2-200 Winding wires - Test methods - Part 2.Determination of
dimensions (IEC 60851-2.1997, IDT)
IEC 61033.1991 Test methods for the determination of bond strength of
impregnating agents to an enamelled wire substrate
ISO 178.2001 Plastics - Determination of flexural properties
After peeling and rotating, the specimen shall be examined for loss of adhesion. If the
coating can be removed from the wire without difficulty (for example with the
thumbnail), it shall be considered to have lost its adhesion even if it has not become
completely detached from the wire.
One specimen shall be tested. It shall be reported, if loss of adhesion is observed.
5.5 Adherence test
A straight piece of wire of about 300 mm length, shall be elongated in accordance with
clause 3 to the percentage specified in the relevant standard.
5.5.1 Enamelled rectangular wire
Before elongation, the coating shall be cut circumferentially through to the conductor
at a point approximately in the centre of the measured length. After elongation, the
specimen shall be examined for loss of adhesion.
One specimen shall be tested. It shall be reported, if loss of adhesion is observed,
measured longitudinally from the cut. If so, the length of loss of adhesion shall be
measured in one direction from the cut. The maximum value observed shall be reported
after examining all sides of the specimen.
5.5.2 Impregnated fibre covered round and rectangular wire
Before elongation, the insulation shall be removed from all but the central 100 mm of
the wire piece. After elongation, the specimen shall be examined for loss of adhesion.
One specimen shall be tested. It shall be reported, if loss of adhesion is observed with
the insulation sliding along the conductor in case of round wire or being detached in
case of rectangular wire.
5.5.3 Fibre covered enamelled round and rectangular wire
Before elongation, the insulation shall be cut circumferentially at two places 100 mm
apart in the centre of the wire piece through to the conductor. After elongation, the
specimen shall be examined for loss of adhesion.
One specimen shall be tested. It shall be reported, if loss of adhesion is observed.
5.5.4 Tape wrapped round and rectangular wire (only applicable to adhesive tape)
Before elongation, the insulation shall be cut circumferentially through to the conductor
at a point approximately in the centre of the measured length. After elongation, the
specimen shall be examined for loss of adhesion.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4074.1Test methods of winding wires - Part 1: General
- GB/T 4074.1-2008Test methods of winding wires - Part 1: General
- GB/T 4074.2Test methods of winding wires - Part 2: Determination of dimensions
GB/T 4074 · IEC 60851 · IEC 61033.1991 · ISO 178.2001
Cited by
- GB/T 4074.1-2024Test methods of winding wires - Part 1: General
- GB/T 4074.4-2024Test methods of winding wires - Part 4: Chemical properties
- GB/T 4074.6-2024Test methods of winding wires - Part 6: Thermal properties
- GB/T 33597-2017Continuously transposed conductors
- JB/T 5327-2014Germanium-manganese-copper Alloy Wires for Resistance and Polyester Enameled Wires
- JB/T 5328-2014Nickel-chromium precision resistance alloy bare wires and polyester enamelled wires
How to Download GB/T 4074.3-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4074.1-2024 — Test methods of winding wires - Part 1: General
GB/T 4074.2-2024 — Test methods of winding wires - Part 2: Determination of dimensions
GB/T 4074.21-2018 — Winding wires test methods—Part 21: Electrical endurance under high frequency voltage impulses
Secure payment via Stripe
Payments accepted
GB/T 4074.3-2008
$420.00