GB/T 33597-2017Continuously transposed conductors (English PDF)
换位导线
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 33597-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 12, 2017
Implementation date
December 1, 2017
Scope
GB/T 33597-2017 is the English-translated version of 换位导线.
GB/T 33597-2017 covers continuously transposed conductors, made by combining a number of enamelled rectangular copper wires into two columns in broad-face contact, transposing them in the same direction over their narrow faces, and then wrapping or binding them with electrical insulating paper, cord or tape.
It sets the terms and definitions, the code, model and product designation, the technical requirements, the test methods, the inspection rules, and packaging, marking and storage, and it defines the transposition pitch as the axial length between two adjacent transpositions.
It applies to the winding coils of power transformers, reactors and special transformers. Informative annexes describe high-elongation fibre paper, aromatic polyamide paper and a bending stiffness test, and a normative annex gives the test for resistance unbalance. It was issued on 12 May 2017 and has applied since 1 December 2017.
Found what you need?
Document preview — GB/T 33597-2017
National Standard of the People's Republic of China
- ICS
- 29.060.01
- Classification
- K 12
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Terms and definitions
- 4 code, model and product representation
- 5 Technical requirements
- 6 Test Method
- 7 Inspection rules
- 8 Packaging, marking and storage
- Appendix A (informative) High elongation fiber paper
- Appendix B (informative) Aromatic polyamide paper
- Appendix C (informative) Test method for bending rigidity of transposition conductors
- Appendix D (Normative Appendix) Test Method for Resistance Unbalance between Trays
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the terms and definitions of transposition conductors, codes, models and product representations, technical requirements, test methods, inspection rules, Packaging, marking and storage.
This standard applies to power transformers, reactors and special transformers and other winding coil with transposition wire.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 228.1 Metallic materials - Tensile testing - Part 1: Test methods for room temperature
GB/T 3048.14 Test methods for electrical performance of wire and cable - Part 14: DC voltage test
GB/T 4074.1 Test methods for winding wires - Part 1: General provisions
GB/T 4074.2 Test methods for winding wires - Part 2: Dimensional measurements
GB/T 4074.3 Test methods for winding wires - Part 3: Mechanical properties
GB/T 4074.5 Test methods for winding wires - Part 5: Electrical properties
GB/T 7095.2 enamelled copper flat winding wire - Part 2: 120 grade acetal enamelled copper flat wire
GB/T 7095.3 enamelled round copper wire winding wire - Part 3: 155 - grade polyester enamelled copper flat wire
GB/T 7095.4 enamelled round copper wire winding wire - Part 4: Class 180 polyesterimide enamelled copper flat wire
GB/T 7095.6 enamelled copper flat winding wires - Part 6: Class 200 polyester or polyester imide/polyamide imide composite enamelled copper Flat line
GB/T 7969 Power Cable Paper
GB/T 23310 grade 240 aromatic polyimide film wrapped copper flat wire
JB/T 9554 Polyester fiber nonwovens for electrical
QB/T 4250 500kV Transformer Turn - to - turn Insulation Paper
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Transposition conductor
To a certain number of enameled flat wire combined into a wide range of contact with each other in two columns, according to technical requirements in the two rows of enameled flat wire above and below The narrow surface of the same steering transposition, and electrical insulation paper, rope or belt for continuous winding or bundled winding wire.
3.2 Transposition pitch
The length of an orbital flattened wire after a complete transposition cycle and the number of enameled flat wires Quotient, i.e., the axial length between two adjacent transitions.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 228.1Metallic Materials — Tensile Testing — Part 1: Method of Test at Room Temperature
- GB/T 3048.14Test methods for electrical properties of electric cables and wires -- Part 14: DC voltage test
- GB/T 4074.1Test methods of winding wires - Part 1: General
- GB/T 4074.2Test methods of winding wires - Part 2: Determination of dimensions
- GB/T 4074.3Test methods of winding wires-Part 3: Mechanical properties
- GB/T 4074.5Test methods of winding wires - Part 5: Electrical properties
Similar standards
How to Download GB/T 33597-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 228.1-2021 — Metallic Materials — Tensile Testing — Part 1: Method of Test at Room Temperature
GB/T 23310-2009 — Aromatic polyimide tape wrapped rectangular copper wire, class 240
GB/T 3048.14-2007 — Test methods for electrical properties of electric cables and wires -- Part 14: DC voltage test
Secure payment via Stripe
Payments accepted
GB/T 33597-2017
$295.00