GB/T 36283-2018General technical specifications for secondary cabin of smart substation (English PDF)
智能变电站二次舱通用技术条件
This is a limited preview
Buy now to download the full PDF (23 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36283-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 7, 2018
Implementation date
January 1, 2019
Scope
GB/T 36283-2018 is the English-translated version of 智能变电站二次舱通用技术条件.
GB/T 36283-2018 gives the general technical specification for the secondary cabin of a smart substation.
It covers the technical requirements, test methods, inspection rules, marking, packaging, lifting, transport and storage of these cabins, and its informative annexes deal with printing on the cabin, the position and size of the external grounding point, deflection measurement and rain tightness testing.
It applies to the design, production and quality inspection of secondary cabins for 110 (66) kV to 750 kV smart substations in power systems, and other plants and stations may refer to it.
The requirements draw on standards for enclosure protection (IP code), salt spray testing, fire resistance of building components, fire doors, emergency lighting and paint film adhesion. It was issued on 7 June 2018 and has applied since 1 January 2019.
Found what you need?
Document preview — GB/T 36283-2018
National Standard of the People's Republic of China
- ICS
- 29.240
- Classification
- K 45
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Technical Requirements
- 5 Test method
- 6 Inspection Rules
- 7 Signs, packaging, lifting transport and storage
- 8 Others
- Appendix A (Informative) Secondary Tank Printing Recommendations
- Appendix B (informative annex) Secondary compartment external grounding recommended position and size
- Appendix C (Informative) Recommendations for Deflection Measurement of Secondary Cabins
- Appendix D (Informative Appendix) Recommendations for Secondary Cabin Rain Tightness Testing
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the technical requirements, test methods, inspection rules, markings, packaging, lifting transportation and storage of the secondary substations of smart substations.
This standard applies to the design, production, and production of secondary cabins (hereinafter referred to as secondary compartments) for 110(66)kV~750kV smart substations in power systems. Quality inspection, other factory stations can refer to the implementation.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 191-2008 Packaging, Storage and Transportation Icon Mark (ISO 780:1997, MOD)
GB/T 2423.17-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Ka. Salt spray
GB/T 2900.1-2008 Basic terminology for electrical terminology
GB/T 2900.17-2009 Electrotechnical term measuring relay
GB/T 2900.49-2004 Electrotechnical terminology power system protection (IEC 60050-448:1995, IDT)
GB/T 4208-2017 enclosure protection class (IP code) (IEC 60529:2013, IDT)
GB/T 4728.2-2005 Graphical symbols for electrical diagrams Part 2. Symbolic elements, qualifiers and other commonly used symbols
GB/T 5169.16-2017 Fire hazard test for electric and electronic products Part 16. Test flame 50W Horizontal and vertical fire Flame test method
GB/T 5700-2008 Lighting Measurement Method
GB/T 8582-2008 Mechanical and electrical equipment mechanical structure terminology
GB 8624-2012 Classification of combustion performance of building materials and products
GB/T 8625-2005 Test method for flame retardancy of building materials
GB/T 9286-1998 Cross-cut test of paint and varnish paint films
GB/T 9761-2008 Visual color comparison of paints and varnishes (ISO 3668:1998, IDT)
GB/T 9799-2011 Treated zinc plating on steel and other inorganic coatings
GB/T 9978.1-2008 Fire resistance test methods for building components Part 1. General requirements
GB/T 9978.8-2008 Fire resistance test methods for building components Part 8. Particular requirements for non-load-bearing vertical partition members
GB 12955-2008 Fire doors
GB/T 14598.27-2017 Measuring relays and protection devices - Part 27. Product safety requirements (IEC 60255-27:2013, IDT)
GB/T 17249.1-1998 Acoustics Low Noise Workplace Design Guide Noise Control Plan
GB/T 17742-2008 China earthquake intensity table
GB 17945-2010 Fire Emergency Lighting and Evacuation Indication System
GB/T 19183.5-2003 Electronic equipment, mechanical structures, outdoor enclosures - Part 3. Climatic and mechanical tests of cabinets and cabinets And safety requirements
GB/T 19804-2005 General dimensional and form tolerances for welded structures
GB 50016-2014 Code for Design of Building Fire Protection
GB 50034-2013 Architectural Lighting Design Standard
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191-2008Graphical symbols marking for handling and storage of packages
- GB/T 2423.17-2008Environmental testing - Part 2: Test methods - Test Ka: Salt mist
- GB/T 2900.1-2008Electrotechnical terminology - Fundamental terms
- GB/T 2900.17-2009Electrotechnical terminology - Measuring relays and protection equipment
- GB/T 2900.49-2004Electrotechnical terminology -- Power system protection
- GB/T 4208-2017Degrees of protection provided by enclosures (IP code)
GB 50034-2013
Similar standards
How to Download GB/T 36283-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 17945-2010 — Fire emergency lighting and evacuate indicating system
GB 50016-2014 — Code for Fire Protection Design of Buildings (2018 Edition)
GB 8624-2012 — Classification for burning behavior of building materials and products
Secure payment via Stripe
Payments accepted
GB/T 36283-2018