Scope
GB/T 22717-2008 is the English-translated version of 电机磁极线圈及磁场绕组匝间绝缘试验规范.
GB/T 22717-2008 is the Chinese standard "Test specifications of interturn insulation of field pole coil and field winding for electrical machines". Its scope clause reads: This standard specifies the inter-turn coil and a magnetic field motor winding insulation test method and test limits.
This standard applies to DC motor, synchronous motor poles between the coil and the field winding turn insulation withstand voltage test. Its clauses include test equipment requirements; test methods and limits.
Found what you need?
Document preview — GB/T 22717-2008
National Standard of the People's Republic of China
- ICS
- 29.160.01
- Classification
- K 20
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 test equipment requirements
- 4 Test methods and limits
1 Scope
This standard specifies the inter-turn coil and a magnetic field motor winding insulation test method and test limits.
This standard applies to DC motor, synchronous motor poles between the coil and the field winding turn insulation withstand voltage test.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1029-2005 Test method for three-phase synchronous motors
3 test equipment requirements
Inter-turn impulse withstand voltage test equipment should meet the following requirements.
--- Instrument uses a capacitor discharge ringing as inter-turn test voltage. Between manufacturer and user Unless otherwise specified, the capacitance
It is set to 5 times the number of discharges. The first peak voltage apparent front time for 0.2µs (tolerance
+0.3
-0.1µs) Or 1.2µs (Tolerance ± 30%), the former first priority wave time is 0.2µs.
Two --- instrument output voltage shock wave should be symmetrical (with a tolerance of ± 3%). Allows the instrument to a single set of output voltage shock wave or a single group
Converted into two groups impulse voltage impulse voltage wave output.
The maximum impulse voltage peak --- instrument output should be able to satisfy the relevant test requirements for the highest Test Limits, a tolerance of ± 5% or
± 3%, the first priority ± 3%.
Impulse voltage peak --- instrument output should be continuously adjustable, and there are instructions or pre-programmed.
--- Instrument should be able to clearly distinguish the waveform display and waveform scanning frequency adjustable.
--- Instrument shall be capable of continuous reliable operation.
--- Instrument should be equipped with a dedicated test line, a reliable ground terminal and the necessary safety warning facilities, test conversion wiring should be convenient and reliable.
4 Test methods and limits
4.1 DC
4.1.1 Inter-turn impulse withstand voltage test
Assessment for inter-turn insulation voltage to withstand the impact of capacity, quality control insulation between turns.
Impulse voltage generated by the discharge of the capacitor is directly applied to the lead wire between poles or magnetic coil windings.
Single pole test coil should be set aside on the ground well insulated shelf. Magnetic coil mounted stator (or rotor) after the root can
It is necessary to take pole coil winding part or the entire winding turn test, with the rest of the test coil or wire winding not vote again related to the magnetic circuit
Lead end turns or windings should be shorted together with a core grounding to prevent an induced voltage in the coil. Helical coil rewind rewind
It must be provided with an insulating layer between turns.
Interturn short circuit determination waveform comparison method can be used to test waveform with the normal waveform is a coil or winding comparison waveform consistent in compliance.
You can use other effective identification method. Waveform comparison may or winding a coil in the normal state and abnormal state of the waveform into the case
Comparing, you can compare two identical coil or winding waveform specification. When two coils or windings tested, it should be both […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 47117-2026Inspection methods for active magnetic bearing stators
- NB/T 10952-2022KCB series mine flameproof switched reluctance motor (frame No.280 ~ 450)
- GB/T 16318-2021Basic test method for rotating traction electrical machines
- JB/T 11816-2014Specification for small brushless three-phase synchronous generators
- JB/T 11817-2014Specification for small single-phase synchronous generators
- JB/T 8667.2-2013Technical specifications for large three-phase synchronous motors - Part 2: TL series
Similar standards
How to Download GB/T 22717-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 22717-2008
$35.00