YY 0505-2012Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests (English PDF)

医用电气设备 第1-2部分:安全通用要求并列标准:电磁兼容 要求和试验

Preview PDF

This is a limited preview

Buy now to download the full PDF (124 pages)

Need quotation for your management?

Get a formal quotation for YY 0505-2012 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Mandatory

Issue date

December 17, 2012

Implementation date

January 1, 2014

Scope

YY 0505-2012 is the English-translated version of 医用电气设备 第1-2部分:安全通用要求并列标准:电磁兼容 要求和试验.

YY 0505-2012 is the Chinese collateral standard on electromagnetic compatibility for medical electrical equipment, the companion to the general safety standard GB 9706.1-2007.

It is an identical adoption of IEC 60601-1-2:2004 (edition 2.1) and sets the requirements and tests for both emission and immunity, together with what the manufacturer must declare in the accompanying documents, including the tables of electromagnetic environment and recommended separation distances between the equipment and portable radio-frequency transmitters.

Its informative appendices give the rationale, worked examples of the declaration tables, guidance on classification under GB 4824, guidance on identifying essential performance and on when non-medical equipment used within a system is exempt from these tests.

It replaces YY 0505-2005, adding requirements for type A special equipment and systems, was issued on 17 December 2012 and has applied since 1 January 2014.

Found what you need?

Document preview — YY 0505-2012

National Standard of the People's Republic of China

Replacing
YY 0505-2005

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword3
  • Introduction5
  • SECTION ONE - GENERAL8
  • 1 Scope and object8
  • 2 Terminology and definitions8
  • 3 General requirements14
  • 6 Identification, marking and documents15
  • SECTION TWO - FOUR40
  • SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION40
  • 36 ELECTROMAGNETIC COMPATIBILITY40
  • SECTION SIX - TEN65
  • Annex A (Informative) General guidance and rationale66
  • Annex B (Informative) Example completion of Tables 201 through 208102
  • Annex C (Informative) Guidance in classification according to GB 4824112
  • Annex D (Informative) Guidance in the application of YY 0505 to Particular Standards116
  • Annex E (Informative) Electromagnetic environments120
  • Annex F (Normative) Normative references121
  • Annex G (Informative) Guidance in the identification of essential performance123
  • Annex H (Informative) Guidance for determining if non-medical electrical equipment used in a system is exempt from the EMC testing requirements of this Standard124

Foreword

This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.

The standard for safety of medical electrical equipment mainly consists of the first part "general requirements for safety" and the second part "specific requirements for safety".

This Standard is a collateral standard of GB 9706.1-2007 Medical electrical equipment - Part 1: General requirements for safety. In addition to this Standard, other relative collateral standards of GB 9706.1-2007 are as follows.

- GB 9706.15-2008 Medical electrical equipment - Part 1: General requirements for safety - 1.Collateral standard. Safety requirements for medical electrical systems (IEC 60601-1-1:2000, IDT);

- GB 9706.12-1997 Medical electrical equipment - Part 1: General requirements for safety 3.collateral STANDARD. General requirements for radiation protection in diagnostic X-ray equipment (idt, IEC 60601-1- 3.1994);

- YY/T 0708-2009 Medical electrical equipment - Part 1-4.General requirements for safety - collateral standard. programmable electrical medical systems (IEC 60601-1-4:2000, IDT);

- YY 0709-2009 Medical electrical equipment - Part 1-8.General requirements for safety - Collateral standard. General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems (IEC 60601-1-8:2003, IDT).

This Standard replaces YY 0505-2005 Medical electrical equipment - Part 1-2.

General requirements for safety - Collateral standards. Electromagnetic compatibility - Requirements and tests.

Compared this Standard with YY 0505-2005, the main differences are as follows of which this Standard.

- made some editorial modifications so as to be consistent with the base standard; for example, "radio frequency electromagnetic field radiation" was modified to "radio frequency electromagnetic field radiation"; "RF" was modified to "Radio Frequency";

- added requirements for A type special equipment and system;

- added YY 0709-2009 into references; deleted IEC 60601-1:1988 (see Annex F);

- added Annex G, Annex H;

- used five bold to express terms and terms of reference in Clause 2.

This Standard identically adopts IEC 60601-1-2:2004 (Edition 2.1), i.e., IEC 60601-1-2:2001+A1.2004 Medical electrical equipment - Part 1-2.General requirements for safety - Collateral standard. Electromagnetic compatibility - Requirements and tests. Compared with IEC 60601-1-2:2004 (Edition 2.1), this Standard makes the following editorial modifications.

- modified some layout formats in accordance with GB/T 1.1;

- for other international standards which are used as references in standard, if they have been converted into China national standards, this Standard shall replace the international standard number with the corresponding one of the national standard number of which the relation of use shall be indicated in Annex F;

- for editorial convenience, adjusted the appendix code from three letters to one letter; for example, Annex AAA was adjusted to Annex A.

1 Scope and object

This Standard applies to ELECTROMAGNETIC COMPATIBILITY of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereinafter referred to as EQUIPMENT and SYSTEMS, respectively.

2 Terminology and definitions

For the purposes of this Collateral Standard, the terms and definitions given in

GB 9706.1-2007, GB 9706.15-2008, YY 0709-2009, YY/T 0316-2008 and the following apply.

3 General requirements

Either the essential performance of the EQUIPMENT or SYSTEM shall be identified (see Annex G for guidance on identifying the essential performance) or the performance of all FUNCTIONS of the EQUIPMENT or SYSTEM shall be considered essential performance for the purpose of IMMUNITY testing [see

6 Identification, marking and documents

This equipment/system is intended for use by healthcare professionals only. where "[EQUIPMENT or SYSTEM]" shall be replaced with the MODEL or TYPE REFERENCE of the EQUIPMENT or SYSTEM.

36 ELECTROMAGNETIC COMPATIBILITY

MEDICAL ELECTRICAL EQUIPMENT containing only simple electrical components like motors and switches and not utilizing any electronic circuitry that generates or uses frequencies above 9 kHz (e.g. some dental drills, some ventilators, some operating tables) may be classified in accordance with GB 4343.1.

Non-medical electrical equipment that is supplied as part of a SYSTEM is exempt from the EMC testing requirements of this Standard, provided all of the following conditions are met (see also Annex H).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 124 pages — is available in the English PDF.

Referenced standards

Cited by

Similar standards

Editions of YY 0505

EditionTitleRevisionStatus
YY 0505-2012Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and testscurrent editionCurrent
YY 0505-2005Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and testsprevious editionSuperseded

This page sells the current edition, YY 0505-2012. Earlier editions are listed for reference only.

How to Download YY 0505-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
124 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 0505-2012

$165.00