Valid

YY/T 1635-2018Multi-channels electrophysiology recording system (English PDF)

多道生理记录仪

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1635-2018 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 20, 2018

Implementation date

January 1, 2020

Scope

YY/T 1635-2018 is the English-translated version of 多道生理记录仪.

YY/T 1635-2018 is the Chinese pharmaceutical industry standard for the multi-channel electrophysiology recording system, the equipment that records and displays surface and intracardiac electrograms beat by beat so that the rhythm can be judged.

It sets the requirements and the test methods, covering the number and bandwidth of the channels, the input impedance and noise, the common mode rejection, the amplitude and time accuracy of the recording, the filters, the display and the printed trace, the defibrillation protection and the electrical safety. Issued on 20 December 2018, it has applied since 1 January 2020.

Found what you need?

Document preview — YY/T 1635-2018

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 39

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Multi-channel physiological recorder
  • 4 Requirements
  • 4.1 Working conditions
  • 4.2 Equipment Requirements
  • 4.3 Security requirements
  • 4.4 Electromagnetic compatibility requirements
  • 4.5 Environmental Test Requirements
  • 5 Test method
  • 5.1 General Test Requirements
  • 5.2 Test conditions
  • 5.3 Test device
  • 5.4 Test circuit
  • 5.5 Test signal and output measurement
  • 5.6 Noise interference
  • 5.7 Recording conditions
  • 5.8 Requirements
  • Appendix A (informative)
  • A.1 Introduction
  • A.2 The reasons for the various clauses in the standard

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

Introduction

The technical indicators of this standard body surface electrocardiogram refer to the requirements of YY 1139-2013 "Electrocardial Diagnostic Equipment".

The technical indicators of this standard intracardiac electrocardiogram refer to the requirements of YY 1139-2013 "Electrocardial Diagnostic Equipment", due to the surface electrocardiogram and heart The internal electrocardiogram has different frequency bands and different impedances. The main technical differences between YY 1139 and 2013 are as follows.

--- Revised the requirements of working conditions;

--- Removed the requirements defined by the lead;

--- Revised the input dynamic range;

--- Revised the requirements for gain setting and accuracy;

--- Revised time base selection and accuracy requirements;

--- Revised the requirements for track width and visibility;

--- Revised the requirements for frequency and impulse response;

--- Removed the requirement for the lead weighting factor;

--- Revised the requirements for input impedance;

--- Revised the requirements for common mode suppression;

--- Revised the requirements for system noise;

--- Revised the requirements for channel crosstalk;

--- Revised the requirements for overload protection;

--- Removed the requirement for hazardous currents;

--- Revised the requirements for auxiliary output.

This standard has a blood pressure technical indicators cited YY 0783-2010 "medical electrical equipment section 2-34. invasive blood pressure monitoring Requirements for special requirements for safety and basic performance, as multi-channel physiological recorders are cardiac electrophysiological surgical equipment, with YY 0783- The main technical differences in 2010 are as follows.

--- Removed the request for an alarm.

This standard non-invasive blood pressure technical indicators cited YY 0667-2008 "medical electrical equipment part 2-30. automatic circulation non-invasive blood Special requirements for safety and basic performance of pressure monitoring equipment, YY 0670-2008 "non-invasive automatic measurement of blood pressure monitor" requirements, due to multi-channel students The logger is a cardiac electrophysiology surgical device, and the main technical differences with YY 0667-2008 are as follows.

--- Removed the request for an alarm.

The technical indicators of this standard blood oxygen monitoring reference YY 0784-2010 "medical electrical equipment medical pulse oximeter equipment basic security The requirements for full and main performance specific requirements, because multi-channel physiological recorder is a cardiac electrophysiology surgical equipment, and YY 0784-2010 main The technical differences are as follows.

1 Scope

This standard specifies the requirements and test methods for multiple physiological recorders.

This standard is applicable to multi-channel physiological recorders, and its scope of application is used to collect human body surface electrocardiogram and intracardiac electrocardiographic characteristic signals.

Continuously recorded and/or displayed device that depicts the waveform of each cardiac cycle and the beat changes reflected to determine the heart rhythm;

The device can also have auxiliary functions such as non-invasive blood pressure monitoring, invasive blood pressure monitoring, and pulse oximetry monitoring. This standard does not apply to ECG monitors.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety

GB 10793-2000 Medical electrical equipment - Part 2. Particular requirements for safety of electrocardiograph

GB/T 14710-2009 Environmental requirements and test methods for medical electrical equipment

YY 0505-2012 Medical Electrical Equipment - Part 1-2. Safety General Requirements Parallel Standard. Electromagnetic Compatibility Requirements and Test

YY 0667-2008 Medical electrical equipment - Part 2-30. Safety and basic performance of automatic cycle non-invasive blood pressure monitoring equipment Requirements

YY 0670-2008 Non-invasive automatic measurement sphygmomanometer

YY 0782-2010 Medical electrical equipment - Part 2-51. Safety and basics for recording and analysis of single and multi-channel electrocardiographs Special requirements

YY 0783-2010 Medical electrical equipment - Part 2-34. Particular requirements for safety and basic performance of invasive blood pressure monitoring equipment

YY 0784-2010 Medical electrical equipment Medical pulse oximeter equipment basic safety and main performance specific requirements

YY 1139-2013 ECG diagnostic equipment

3 Terms and definitions

GB 9706.1-2007, YY 0667-2008, YY 0670-2008, YY 0783-2010, YY 0784-2010, YY 1139- The following terms and definitions defined in 2013 apply to this document.

3.1 Multi-channelselectrophysiologyrecordingsystem

A device for collecting a human body surface electrocardiogram and an intracardiac electrocardiographic characteristic signal for continuous recording and/or display, which depicts each The waveform of the cardiac cycle, as well as the beat changes reflected in the determination of the heart rhythm; the device can also have non-invasive blood pressure monitoring, invasive blood pressure monitoring, Auxiliary functions such as pulse oximetry monitoring.

4 Requirements

4.1 Working conditions

It is prescribed by the manufacturer; if it is not specified, it shall comply with the requirements of Chapter 10 of GB 9706.1-2007.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

How to Download YY/T 1635-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1635-2018

$355.00