YY 0989.7-2017Implants for surgery - Active implantable medical devices - Part 7: Particular requirements for cochlear implant systems (English PDF)
手术植入物有源植入式医疗器械 第7部分:人工耳蜗植入系统的专用要求
This is a limited preview
Buy now to download the full PDF (54 pages)
Need quotation for your management?
Get a formal quotation for YY 0989.7-2017 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
July 17, 2017
Implementation date
January 1, 2018
Scope
YY 0989.7-2017 is the English-translated version of 手术植入物有源植入式医疗器械 第7部分:人工耳蜗植入系统的专用要求.
YY 0989.7-2017 is the Chinese standard "Implants for surgery - Active implantable medical devices - Part 7: Particular requirements for cochlear implant systems".
Its scope clause reads: This Part of YY 0989 specifies requirements that are applicable to those active implantable medical devices that are intended to treat hearing impairment via electrical stimulation of the auditory pathways.
Devices which treat hearing impairment via means other than electrical stimulation are not covered by this Part. The tests that are specified in this Part are type tests and are to be carried out on samples of a device to show compliance.
This Part is also applicable to non-implantable parts and accessories of the devices (see NOTE). The electrical characteristics of the implantable part are determined by either the appropriate method detailed in this Part or by any other method demonstrated to have an accuracy equal to, or better than, the method specified.
In the case of dispute, the method detailed in this Part applies. NOTE: A device that is commonly referred to as an active implantable medical device can in fact be a single device, a combination of devices, or a combination of a device or devices and one or more accessories.
Not all of these parts are required to be either partially or totally implantable, but there is a need to specify some requirements of non-implantable parts and accessories if they could affect the safety or performance of the implantable part.
Found what you need?
Document preview — YY 0989.7-2017
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword4
- 1 Scope6
- 2 Normative References6
- 3 Terms and Definitions8
- 4 Symbols and Abbreviations10
- 5 General Requirements for Non-Implantable Parts10
- 6 Inspection and Measurement10
- 7 General Arrangement of the Packaging11
- 8 General Markings for Active Implantable Medical Devices11
- 9 Markings on the Sales Packaging11
- 10 Construction of the Sales Packaging12
- 11 Markings on the Sterile Pack12
- 12 Construction of the Non-Reusable Pack13
- 13 Markings on the Active Implantable Medical Device13
- Implantable Medical Device13
- Features of the Active Implantable Medical Device14
- 16 Protection from Harm to the Patient Caused by Electricity14
- 17 Protection from Harm to the Patient Caused by Heat15
- 19 Protection from Unintended Effects Caused by the Device15
- Fields Applied Directly to the Patient17
- by Miscellaneous Medical Treatments18
- by Electrostatic Discharge28
- by Atmospheric Pressure Changes28
- by Temperature Changes29
- Nonionizing Radiation29
- 28 Accompanying Documentation32
- Annex A (Informative) Basic Principle of this Part35
- Compliance with Clause 2746
- Bibliography54
1 Scope
This Part of YY 0989 specifies requirements that are applicable to those active implantable medical devices that are intended to treat hearing impairment via electrical stimulation of the auditory pathways. Devices which treat hearing impairment via means other than electrical stimulation are not covered by this Part.
The tests that are specified in this Part are type tests and are to be carried out on samples of a device to show compliance.
This Part is also applicable to non-implantable parts and accessories of the devices (see NOTE).
The electrical characteristics of the implantable part are determined by either the appropriate method detailed in this Part or by any other method demonstrated to have an accuracy equal to, or better than, the method specified. In the case of dispute, the method detailed in this Part applies.
NOTE: A device that is commonly referred to as an active implantable medical device can in fact be a single device, a combination of devices, or a combination of a device or devices and one or more accessories. Not all of these parts are required to be either partially or totally implantable, but there is a need to specify some requirements of non-implantable parts and accessories if they could affect the safety or performance of the implantable part.
2 Normative References
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.
This clause of Part 1 applies except as follows:
Additional references:
GB/T 2423.5 Environmental Testing for Electric and Electronic Products Part 2:
Test Methods Test Ea and Guidance: Shock (GB/T 2423.5-1995, IEC 60068-2-
27:1987, IDT)
GB/T 2423.7 Environmental Testing for Electric and Electronic Products - Part 2:
Test Methods Test Ec and Guidance: Drop and Topple Primarily for Equipment-
Type Specimens (GB/T 2423.7-1995, IEC 60068-2-31:1982, IDT)
GB/T 2423.43 Environmental Testing for Electric and Electronic Products - Part 2:
Test Methods - Mounting of Specimens for Vibration Impact and Similar Dynamic
Tests (GB/T 2423.43-2008, IEC 60068-2-47:2005, IDT)
GB/T 2423.56 Environmental Testing for Electric and Electronic Products - Part 2:
Test Methods - Test Fh: Vibration, Broad-Band Random (Digital Control) and
Guidance (GB/T 2423.56-2006, IEC 60068-2-64:1993, IDT)
GB/T 2423.55 Environmental Testing for Electric and Electronic Products - Part 2:
Test Methods - Test Eh: Hammer Tests (GB/T 2423.55-2006, IEC 60068-2-
75:1997, IDT)
GB/T 16886.1 Biological Evaluation of Medical Devices - Part 1: Evaluation and
Testing within a Risk Management Process (GB/T 16886.1-2011, ISO 10993-
1:2009, IDT)
GB/T 17626.2 Electromagnetic Compatibility (EMC) - Testing and Measurement
Techniques - Electrostatic Discharge Immunity Test (GB/T 17626.2-2006, IEC 61000-4-2:2001, IDT)
GB/T 19633 Packaging for Terminally Sterilized Medical Devices (GB/T 19633-
2005, ISO 11607:2003, IDT)
YY/T 0316 Medical Devices - Application of Risk Management to Medical Devices (YY/T 0316-2016, ISO 14971:2007 corrected version, IDT)
YY 0505 Medical Electrical Equipment - Part 1-2: General Requirements for Safety
-Collateral Standards: Electromagnetic Compatibility - Requirements and Tests (YY 0505-2012, IEC 60601-1-2:2004)
YY/T 0664 Medical Device Software - Software Life Cycle Processes (YY/T 0664
-2008, IEC 62304:2006, IDT)
ISO 14155 Clinical Investigation of Medical Devices for Human Subjects - Good
Clinical Practice
IEC 60118-6 Hearing Aids - Part 6: Characteristics of Electrical Input Circuits for
Hearing Aids
YY/T 0987.5-2016 | YY/T 0988.14-2016 | YY/T 0988.2-2016 | YY 0989.6-2025 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 54 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.5Environmental testing - Part 2: Test methods - Test Ea and guidance: Shock
- GB/T 2423.7Environmental testing - Part 2: Test methods - Test Ec: Rough handling shocks, primarily for equipment-type specimens
- GB/T 2423.43Environmental testing for electric and electronic products - Part 2: Test methods - Mounting of specimens for vibration, impact and similar dynamic tests
- GB/T 2423.56Environmental testing - Part 2: Test methods - Test Fh: Vibration, broadband random and guidance
- GB/T 2423.55Environmental testing - Part 2: Test methods - Test Eh: Hammer tests
- GB/T 16886.1Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 19633 · ISO 14155 · IEC 60118-6
Similar standards
How to Download YY 0989.7-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 17626.2-2018 — Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
GB/T 19633.1-2024 — Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems
Secure payment via Stripe
Payments accepted
YY 0989.7-2017
$285.00