Valid

GB/T 17215.321-2021Electricity metering equipment (AC) - Particular requirements - Part 21: Static meters for active energy(classes A, B, C, D and E) (English PDF)

电测量设备(交流) 特殊要求 第21部分:静止式有功电能表 (A级、B级、C级、D级和E级)

Open the GB/T 17215.321-2021 preview as PDF

Preview — first pages of GB/T 17215.321-2021 (full document: 29 pages)

This is a limited preview

Buy now to download the full PDF (29 pages)

Issued by

State Administration for Market Regulation; Standardization Administration of China

Level / Type

National · Recommended

Issue date

April 30, 2021

Implementation date

November 1, 2021

Scope

GB/T 17215.321-2021 is the English-translated version of 电测量设备(交流) 特殊要求 第21部分:静止式有功电能表 (A级、B级、C级、D级和E级).

GB/T 17215.321-2021 is the Chinese national standard on electricity metering equipment (ac) - particular requirements - part 21: static meters for active energy(classes a, b, c, d and e), in the field of metrology and measurement. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 30 April 2021 by the State Administration for Market Regulation; Standardization Administration of China, and has been in force since 1 November 2021. Classification: ICS 17.220.20, CCS N22. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB/T 17215.321-2021

National Standard of the People's Republic of China

ICS
17.220.20
Classification
N22

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • 4 Introduction...8
  • 1 Scope...10
  • 2 Normative references...12
  • 3 Terms and definitions...12
  • 4 Standard electricity value...13
  • 4.1 Voltage...13
  • 4.2 Current...13
  • 4.3 Frequency...13
  • 4.4 Power consumption...14
  • 5 Structure...14
  • 5.1 General requirements...14
  • 5.2 Mechanical test...14
  • 5.3 Windows...14
  • 5.4 Sealing requirements...14
  • 5.5 Display of measured value...14
  • 5.6 Storage of measured values...14
  • 5.7 Output...15
  • 5.8 Electrical pulse input...15
  • 5.9 Working indicator...15
  • 5.10 Protection against mechanical hazards...15
  • 5.11 Measures to protect the connection...15
  • 5.12 Prevention of flame spreading...15
  • 5.13 Meter temperature limit and heat resistance...15
  • 6 Marking and documentation of the meter...16
  • 7 Metering performance...16
  • 7.1 General test conditions...16
  • 7.2 Methods of accuracy verification...16
  • 7.3 Meter constant test...17
  • 7.4 No-load condition (creeping) test...17
  • 7.5 Starting current test...17
  • 7.6 Basic maximum allowable error...17
  • 7.7 Repeatability test...18
  • 7.8 Variation requirement test...18
  • 7.9 Variation test of load current rise and fall...19
  • 7.10 Error consistency test...19
  • 7.11 Error limit test due to influence quantity...19
  • 7.12 Combined error test of electric energy indication...23
  • 7.13 Timing accuracy test...23
  • 7.14 Combined maximum allowable error test...23
  • 8 Climatic environment...23
  • 9 External influences...23
  • 10 Metering performance protection...23
  • 11 Electrical...24
  • 11.1 Clearance and creepage distances...24
  • 11.2 Electrical test procedure...24
  • 11.3 Tests for voltage circuits...25
  • 11.4 Dielectric strength test...25
  • 11.5 Short-time overcurrent test...25

1 Scope

GB/T 17215.321-2021 is the Chinese national standard on electricity metering equipment (ac) - particular requirements - part 21: static meters for active energy(classes a, b, c, d and e), in the field of metrology and measurement. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 30 April 2021 by the State Administration for Market Regulation; Standardization Administration of China, and has been in force since 1 November 2021. Classification: ICS 17.220.20, CCS N22. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

This Part of GB/T 17215.3 specifies the standard electricity value, structure, meter's marking and documentation, metering performance, climate environment, external influence, metering performance protection, electrical requirements, for static meters for active energy. This Part of GB/T 17215.3 is only applicable to the newly manufactured static meters for active energy, which is used to measure the AC active energy, in

60 Hz power grid, AND has an accuracy class of A, B, C, D, E. (below referred to as "meter"). It is also applicable to other type tests.

Note 1: For other requirements (such as structure, EMC, reliability), refer to GB/T 17215.211- 2021, as well as the relevant parts of GB/T 17215.911, GB/T 17215.921, GB/T 17215.9311, GB/T 17215.9321, GB/T 17215.941. This Part applies to newly manufactured electricity metering equipment, which is used to meter and control electrical energy in the power grid, that has a voltage not exceeding 600 V. All special functional units, except the electrical energy measuring function, can be integrated in the meter enclosure, OR can form a separate enclosure.

Note 2: The above voltage is the line-to-neutral line voltage, which is derived from the nominal voltage, as shown in Table 7 of IEC 62052-31:2015. If the meter has functions other than metering active energy, for example: - Measurement of voltage amplitude, current amplitude, power, frequency, power factor, etc.; - Measurement of power quality parameters; - Load control function; - Data communication interface. If encapsulated in the meter enclosure, the relevant standards can apply to these functional requirements. However, the requirements for these functions are not within the scope of this Part.

Note 3: The requirements for power monitoring devices and measurement functions (such as voltage amplitude, current amplitude, power, frequency, etc.) have been covered in GB/T 18216.12; BUT equipment, that complies with GB/T 18216.12, is not suitable as a payment meter, unless they also meet the accuracy class requirements of this Part.

Note 4: The requirements for power quality monitoring meters have been covered in IEC 62586-1. The measurement methods for power quality monitoring functions have been covered in GB/T 17626.30-2012. The test requirements for power quality monitoring functions are covered in IEC 62586-2. The requirements of this Part apply, if the meter is designed to be mounted on a specified mating (meter) socket or rack. The test is performed, with the meter mounted on the specified mating socket or rack. However, the requirements for such socket or rack are outside the scope of this Part.

Note 5: Examples of rack-mounted meters are: rail-mounted meters, panel-mounted meters, etc. If the meter is designed to install a separated indicator display, the requirements of this Part apply; meanwhile, the meter can be connected to its separated indicator display for testing, unless otherwise specified. If the meter has more than one current circuit per phase (for example: multi-unit meter), the requirements of this Part apply to all current circuits of any current-measuring unit, in the meter enclosure. This Part also applies to auxiliary input and output circuits, operating indicators, test outputs of electricity metering equipment.

Note 6: For example, pulse input and output, control input and output, power test output. This Part distinguishes: - Single-phase meters and multi-phase meters; - Directly connected meters and meters connected via a transformer; - Meters with integrated indicating displays and meters with separated indicating displays; - Indoor and outdoor meters. This Part does not apply to: - The meters, which have a line-to-neutral voltage in excess of 600 V derived from the nominal voltage;

4.4 Power consumption Power consumption shall comply with the requirements, test conditions, test procedures, acceptance criteria, which are specified in

4.4 of GB/T 17215.211-2021.

5 Structure

5.1 General requirements The general requirements of the structure shall comply with the provisions in

5.1 of GB/T 17215.211-2021.

5.2 Mechanical test The mechanical test shall comply with the provisions of

5.2 in GB/T 17215.211-2021. It shall also comply with the spring hammer test requirements, test conditions, test procedures, acceptance criteria, which are specified in

8.2 of IEC 62052-31:2015.

5.3 Windows The window requirements shall comply with the provisions in

5.3 of GB/T 17215.211- 2021.

5.4 Sealing requirements The requirements for sealing shall comply with the provisions in

5.4 of GB/T 17215.211-2021.

5.5 Display of measured value The measurement value display requirements shall comply with the provisions of

5.5 in GB/T 17215.211-2021.

5.6 Storage of measured values The storage requirements of the measured values shall comply with the provisions in

5.6 of GB/T 17215.211-2021.

5.7 Output The output requirements shall comply with the provisions of

5.13 Meter temperature limit and heat resistance

5.13.1 Surface temperature limits to prevent burns When the ambient temperature is 40 °C, the temperature of the easy-to-contact surface of the meter shall not exceed the value given in 1) in Table 31 of IEC 62052-31:2015, under normal conditions. When the ambient temperature exceeds 40 °C, the temperature of the easily accessible surface of the meter is allowed to exceed the value, which is given in 1) in Table 31 of IEC 62052-31:2015, BUT the excess value shall not be greater than the difference, between the ambient temperature and 40 °C. The surface of the terminal box, which is covered by the terminal cover, OR the surface of the board-mounted meter, which is protected by the fence, is not regarded as an accessible surface. The test method shall comply with the provisions in

10.4 of IEC 62052-31:2015.

5.13.2 Temperature limits for terminals When the ambient temperature is 40 °C, the temperature of the terminal shall not exceed the value, which is given in Table 32 of IEC 62052-31:2015, under normal conditions. When the ambient temperature exceeds 40 °C, the temperature of the terminal is allowed to exceed the value, which is given in Table 32 of IEC 62052-31:2015, BUT the excess value shall not be greater than the difference, between the ambient temperature and 40 °C. The test method shall comply with the provisions in

10.4 of IEC 62052-31:2015.

6 Marking and documentation of the meter

The marking and documents of the meter shall comply with the provisions of Chapter 6 in GB/T 17215.211-2021.

7 Metering performance

7.1 General test conditions The general test conditions shall comply with the provisions in

7.1 of GB/T 17215.211- 2021.

7.2 Methods of accuracy verification The method of accuracy verification shall comply with the provisions in

7.2 of GB/T 17215.211-2021.

11 Electrical...

11.3 Tests for voltage circuits

11.3.1 Withstand long-term overvoltage test The withstand long-term overvoltage test shall comply with the provisions of

6.10.3.2 in IEC 62052-31:2015.

11.3.2 Surge test The surge test shall comply with the provisions of

9.3.9 in GB/T 17215.211-2021.

11.4 Dielectric strength test

11.4.1 Humidity conditioning The humidity conditioning test shall comply with the provisions in

6.10.4.2 of IEC 62052-31:2015.

11.4.2 Test method and test equipment preparation The dielectric strength test shall comply with the requirements of 6.10.4.3.1 in IEC 62052-31:2015. The preparation of the test equipment shall comply with the requirements in 6.10.4.3.2 of IEC 62052-31:2015.

11.4.3 Impulse voltage test The impulse voltage test shall comply with the provisions of 6.10.4.3.3 in IEC 62052- 31:2015. The test voltage shall comply with the provisions in Table 7 of IEC 62052- 31:2015.

11.4.4 AC power frequency voltage test The AC power frequency voltage test shall comply with the provisions of 6.10.4.3.4 in IEC 62052-31:2015. The test voltage shall comply with the provisions in Table 11 in IEC 62052-31:2015.

11.5 Short-time overcurrent test The short-time overcurrent test shall comply with the provisions of

9.4.11 in GB/T 17215.211-2021.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 29 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 17215.321

EditionTitleRevisionStatus
GB/T 17215.321-2021Electricity metering equipment (AC) - Particular requirements - Part 21: Static meters for active energy(classes A, B, C, D and E)current editionCurrent
GB/T 17215.321-2008Electricity metering equipment (a.c.) - Particular requirements - Part 21: Static meters for active energy (classes 1 and 2)previous editionSuperseded
GB/T 17215.322-2008Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0 2 S and 0 5 S)merged into this editionSuperseded

This page sells the current edition, GB/T 17215.321-2021. Earlier editions are listed for reference only.

How to Buy GB/T 17215.321-2021

  1. 1Add to cart. Click the "Buy GB/T 17215.321-2021" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
29 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17215.321-2021

$275.00

$235.00for partners