GB/T 35732-2025Technical specification for remote terminal units of distribution automation (English PDF)
配电自动化终端技术规范
Open the GB/T 35732-2025 preview as PDF
This is a limited preview
Buy now to download the full PDF (11 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 2, 2025
Implementation date
July 1, 2026
Scope
GB/T 35732-2025 is the English-translated version of 配电自动化终端技术规范.
GB/T 35732-2025 is the Chinese national standard covering the feeder terminal unit on a distribution pole or in a ring main unit - its measurement and fault detection, its communication with the master station, its power supply through an outage, and the environment of heat, cold and lightning it lives in. Issued on 2 December 2025, it has been in force since 1 July 2026, replacing GB/T 35732-2017.
Document preview — GB/T 35732-2025
National Standard of the People's Republic of China
- ICS
- 29.240.01
- Classification
- F 21
- Replacing
- GB/T 35732-2017
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Radio frequency electromagnetic field radiated immunity testing
- 4 Abbreviations
- 5 General Requirements
- 6 Functional Requirements
- 6.1 General Requirements
- 6.2 Feeder Terminal/Station Terminal
- 6.3 Distribution Transformer Terminal
- 6.4 Operation and Maintenance Functions
- 6.5 Structural Appearance
- 7 Technical conditions
- 7.1 Environmental Conditions
- 7.2 Power Supply Requirements
- 7.3 Secondary Circuit
- 8 Performance Requirements
- 8.1 Measurement and Control
- 8.2 Troubleshooting 9
- 8.3 Communication and Time Synchronization 9
- 8.4 Other performance characteristics 9
- 8.5 Insulation performance 10
- 8.6 Electromagnetic compatibility performance 11
- 8.7 Mechanical Vibration 13
- 8.8 Continuous power-on stability 13
- 8.9 Reliability 13
- 9 Test Methods 13
- 9.1 Test Conditions 13
- 9.2 Functional and Performance Tests 14
- 9.3 Communication Experiment 14
- 9.4 Structural and Appearance Tests 14
- 9.5 Power supply influence test 14
- 9.6 Environmental Suitability Test 15
- 9.7 Insulation performance test 15
- 9.8 Electromagnetic compatibility performance test 15
- 9.9 Mechanical performance test 15
- 9.10 Continuous power-on test 15
- 10.1 Mark 15
- 10.2 Packaging 16
- 10.3 Transportation and Storage
- 16 Reference 17
1 Scope
GB/T 35732-2025 is the Chinese national standard covering the feeder terminal unit on a distribution pole or in a ring main unit - its measurement and fault detection, its communication with the master station, its power supply through an outage, and the environment of heat, cold and lightning it lives in. Issued on 2 December 2025, it has been in force since 1 July 2026, replacing GB/T 35732-2017.
This document specifies the general requirements and technical conditions for distribution automation terminals (hereinafter referred to as "terminals"), as well as their functions, performance, markings, and packaging. The requirements for loading, transportation, and storage are described, along with the corresponding test methods. This document applies to the planning, design, procurement, installation, commissioning, testing, acceptance, and operation and maintenance of terminals.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.
GB/T 2423.10-2019 Environmental testing - Part
3 Radio frequency electromagnetic field radiated immunity testing
GB/T 17626.4 Electromagnetic compatibility testing and measurement techniques - Electrical fast transient/burst immunity test
GB/T 17626.5 Electromagnetic compatibility testing and measurement techniques - Surge (impulse) immunity test
GB/T 17626.8 Electromagnetic compatibility testing and measurement techniques - Power frequency magnetic field immunity test
GB/T 17626.9 Electromagnetic compatibility testing and measurement techniques - Pulse magnetic field immunity test
GB/T 17626.10 Electromagnetic compatibility testing and measurement techniques - Damped oscillating magnetic field immunity test
GB/T 17626.11 Electromagnetic compatibility testing and measurement techniques - Part
11.Equipment with input current less than or equal to 16A per phase Voltage sag, short interruption and voltage change immunity test
GB/T 17626.18 Electromagnetic compatibility testing and measurement techniques - Damped oscillating wave immunity test
GB/T 17626.29 Electromagnetic compatibility testing and measurement techniques - DC power supply input port voltage dips, short interruptions and voltage fluctuations Immunity test
GB/T 19638.1-2014 Stationary Valve-Regulated Lead-Acid Batteries - Part
9.10 Continuous power-on test 15
10.Marking, packaging, transportation and storage 15.
16 Reference 17
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part
1.Structure and Drafting Rules of Standardization Documents". Drafting. This document replaces GB/T 35732-2017 "Technical Specification for Intelligent Terminals in Distribution Automation". Compared with GB/T 35732-2017, except for... Aside from structural adjustments and editorial changes, the main technical changes are as follows:
a) The scope has been changed (see Chapter 1, Chapter 1 of the.2017 edition);
b) The definition of "distribution automation terminal" has been changed (see 3.1,.2017 version 3.1);
c) The terms and definitions for "distribution transformer terminal" and "feeder automation" have been added (see
d) Terms and definitions related to distribution automation intelligent terminals have been removed (see sections 3.4, 3.5, 3.6, 3.7, and
3.8 of the.2017 version);
e) Abbreviations have been changed (see Chapter 4, Chapter 4 in the.2017 edition);
f) The general requirements have been changed (see Chapter 5, Chapter 5 of the.2017 edition);
g) The general requirements in the functional requirements (see 6.1,.2017 version 6.1) and the feeder terminal/station terminal measurement and control functions (see...) have been changed. 6.2.1 (see
6.2.1 in the.2017 version), fault handling function (see
6.2.2 in the.2017 version), communication function (see
6.2.3 in the.2017 version). Version 6.4);
h) Added power management function (see 6.2.4), backup power supply (see 6.2.5), other functions (see 6.2.6), and distribution transformer terminal function requirements. (See 6.3), Operation and maintenance functions (see 6.4);
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4208-2017Degrees of protection provided by enclosures (IP code)
- GB/T 7261-2016Basic test methods for protection relays and security automatic equipment
- GB/T 13384General specifications for packing of mechanical and electrical product
- GB/T 13729-2019Remote terminal unit equipment
- GB/T 14285Technical code for relaying protection and security automatic equipment
- GB/T 17215.321-2021Electricity metering equipment (AC) - Particular requirements - Part 21: Static meters for active energy(classes A, B, C, D and E)
GB/T 2423.10-2019 · GB/T 5095 · GB/T 14598.24 · GB/T 14598.27-2025 · GB/T 17215.323-2022 · GB/T 17626.2 · GB/T 17626.3
Editions of GB/T 35732
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 35732-2025 | Technical specifications of remote terminal unit of distribution automation | current edition | Current |
| GB/T 35732-2017 | Technical specifications of intelligent remote terminal unit of distribution automation | previous edition | In force |
This page sells the current edition, GB/T 35732-2025. Earlier editions are listed for reference only.
How to Buy GB/T 35732-2025
- 1Add to cart. Click the "Buy GB/T 35732-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13384-2008 — General specifications for packing of mechanical and electrical product
GB/T 13729-2019 — Remote terminal unit equipment
GB/T 14285-2023 — Technical code for relaying protection and security automatic equipment
Secure payment via Stripe
Payments accepted
GB/T 35732-2025