GB/T 14049-2008Aerial insulated cables for rated voltage of 10kV (English PDF)
额定电压10kV架空绝缘电缆
Open the GB/T 14049-2008 preview as PDF
This is a limited preview
Buy now to download the full PDF (19 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 30, 2008
Implementation date
April 1, 2009
Scope
GB/T 14049-2008 is the English-translated version of 额定电压10kV架空绝缘电缆.
GB/T 14049-2008 is the Chinese national standard on aerial insulated cables for rated voltage of 10kv, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 30 June 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 April 2009. Classification: ICS 29.060.20, CCS K13. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB/T 14049-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K13
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and definitions1
- 4 Symbols and code 2 5 using the characteristics of2
- 6 Models and Specifications 27
- 3 Technical requirements8
- 13 Annex C (normative) Artificial weathering test method (xenon lamp method)15
Foreword
This standard replaces GB 14049-1993 "rated voltage of 10kV, 35kV overhead insulated cables." This standard compared with GB 14049-1993, the main changes are as follows:
--- Standard name changed to "rated voltage of 10kV overhead insulated cables";
--- Deleted on the rated voltage 35kV overhead insulated cable entry (1993 Edition Chapter 1, 3.1.3,4.1, Table 2, Table 3, 7.7.2, Table 5, Table 8);
--- Increasing the nominal cross section 400mm2 (Table 2, Table 3);
--- Delete Conductor Stranding pitch diameter ratio and a predetermined twist to the (1993 version 7.2.5);
--- A sign of increased core method (see 7.3.4);
--- Delete shielded cable insulation partial discharge as a routine test project (1993 version 7.7.4);
--- Modify the impulse voltage test value of 10kV overhead line (1993 edition Table
8 Table 8 of this standard);
--- According to GB/T 1.1-2000 modified format. The Standard Appendix A, Appendix B and Appendix C are normative appendix. The standard proposed by China Electrical Equipment Industrial Association. This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized. This standard was drafted. Shanghai Electric Cable Research Institute, Jiangsu Far East Group Co., Ltd., Haikou Wit Electric Group Co., Ltd., Fujian Nanping Sun Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Yangzhou Shuguang Cable Co., Ltd., Hunan Valin Cable Co., Ltd. Drafters of this Standard. Sun Jiansheng, Wang Chuanbin, Mongolia Zhong Kui, Van der hair, Liu Jun, Liang Guohua, Zhang Gongzhuo. This standard replaces the standards previously issued as follows:
--- GB 14049-1993. Rated voltage overhead insulated cable 10 k Vp
1 Scope
GB/T 14049-2008 is the Chinese national standard on aerial insulated cables for rated voltage of 10kv, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 30 June 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 April 2009. Classification: ICS 29.060.20, CCS K13. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This standard specifies the rated AC voltage of 10kV overhead insulated cables (overhead cable) product models, specifications, technical requirements, test side Law, inspection rules, packaging, transportation and storage. This standard applies to AC rated voltage U (Um) 10 (12) kV overhead power lines with copper, aluminum, aluminum alloy core crosslinked poly Ethylene (XLPE) and high density polyethylene (HDPE) insulated aerial cables.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1179-1999 Round wire concentric gallows empty line (eqv IEC 61089.1991)
GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimension measurement - mechanical physical performance test (idt IEC 60811-1-1.1993)
GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985)
GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. General test elastomeric compounds Party Act 1. Ozone resistance test - Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986)
GB/T 3048.4-2007 electrical wire and cable performance test methods - Part 4. Conductor DC resistance test
GB/T 3048.5-2007 electrical wire and cable performance test methods - Part 5. Insulation resistance test
GB/T 3048.7-2007 electrical wire and cable performance test methods - Part 7. Tracking resistance test
GB/T 3048.8-2007 electrical wire and cable performance test methods - Part 8. AC voltage test ( IEC 60060-1. 1989, NEQ)
GB/T 3048.11-2007 wire and cable electrical performance test methods - Part 11. dielectric loss tangent test
GB/T 3048.12-2007 wire and cable electrical performance test methods - Part 12. Partial discharge tests ( IEC 60885-3. 1988, MOD)
GB/T 3682-2000 quality thermoplastic melt flow rate and melt volume flow rate measurement (idt ISO 1133. 1997)
GB/T 3953-1983 electrician round copper wire (neqASTMB1. 1970)
GB/T 3955-1983 electrician round aluminum (neqASTMB230. 1977)
3 Terms and definitions
3.1 Rated voltage is the reference voltage cable design and operation, represented by U (Um), in units of kV. U
--- cable between two phase conductors
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 3048.4-2007Test methods for electrical properties of electric cables and wires — Part 4: Test of DC resistance of conductors
- GB/T 3048.5-2007Test methods for electrical properties of electric cables and wires - Part 5: Test of insulation resistance
- GB/T 3048.7-2007Test methods for electrical properties of electric cables and wires - Part 7: Tracking resistance test
- GB/T 3048.8-2007Test methods for electrical properties of electric cables and wires - Part 8: AC voltage test
- GB/T 3048.11-2007Test methods for electrical properties of electric cables and wires — Part 11: Test for dielectric dissipation factor
- GB/T 3953-1983Round copper wire for electrical purposes
GB/T 1179-1999 · IEC 61089.1991 · GB/T 2951.1-1997 · IEC 60811 · GB/T 2951.2-1997 · GB/T 2951.5-1997 · IEC 60060 · GB/T 3048.12-2007 · IEC 60885 · GB/T 3682-2000 · ISO 1133 · IEC 60251 · IEC 60207 · JB/T 8134-1995 · JB/T 8137-1999 · JB/T 10696.3-2007
Similar standards
Editions of GB/T 14049
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 14049-2008 | Aerial insulated cables for rated voltage of 10kV | current edition | Current |
| GB 14049-1993 | Aerial insulated cables with rated voltages of 10 Kv and 35 Kv | merged into this edition | Superseded |
This page sells the current edition, GB/T 14049-2008. Earlier editions are listed for reference only.
How to Buy GB/T 14049-2008
- 1Add to cart. Click the "Buy GB/T 14049-2008" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 3048.5-2007 — Test methods for electrical properties of electric cables and wires - Part 5: Test of insulation resistance
GB/T 3048.7-2007 — Test methods for electrical properties of electric cables and wires - Part 7: Tracking resistance test
GB/T 6995.3-2008 — Markings for electric wires and cables - Part 3: Identifications of cables and wires
Secure payment via Stripe
Payments accepted
GB/T 14049-2008
$260.00