Valid

JB/T 501-2006Test guide for power transformers (English PDF)

电力变压器试验导则

Preview PDF

This is a limited preview

Buy now to download the full PDF (40 pages)

Need quotation for your management?

Get a formal quotation for JB/T 501-2006 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

May 6, 2006

Implementation date

October 1, 2006

Scope

JB/T 501-2006 is the English-translated version of 电力变压器试验导则.

JB/T 501-2006 is the Chinese standard "Test guide for power transformers". Its scope clause reads: This standard specifies procedures and methods of routine tests, type tests and special tests for oil-immersed type and dry-type power transformers.

This standard applies to the tests of oil-immersed type and dry-type power transformers. This standard may apply to special transformers. Its clauses include main symbols; test procedure.

Found what you need?

Document preview — JB/T 501-2006

National Standard of the People's Republic of China

Replacing
JB/T 501-1991

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Contents
  • Foreword i
  • 1 Scope
  • 2 Normative references
  • 3 Main symbols
  • 4 Test procedure
  • 5 Oil tank leak test (routine test)
  • 5.1 General requirements
  • 5.2 Test purpose
  • 5.3 Test method
  • 5.4 Judgment of test results
  • 6 Measurement of dielectric characteristics (routine test)
  • 6.1 Test purpose and items
  • 6.2 Measurement of insulation resistance, absorption ratio and polarization index
  • 6.3 Measurement of dielectric dissipation factor
  • 7 Transformer oil test (routine test)
  • 7.1 Measurement of breakdown voltage
  • 7.2 Measurement of dielectric dissipation factor
  • 7.3 Determination of moisture content
  • 7.4 Determination of air content
  • 7.5 Gas chromatographic analysis of dissolved gas
  • 8 Voltage ratio measurement (routine test)
  • 9 Calibration of voltage vector relation (routine test)
  • 9.1 Voltage ratio bridge method
  • 9.2 Double voltmeter method
  • 9.3 Tester method
  • 10 Winding resistance measurement (routine test)
  • 11 Insulation tests (routine, type and special tests)
  • 11.1 General
  • 11.2 Switching impulse and lightning impulse tests
  • 11.3 Applied voltage withstand test (routine test)
  • 11.4 Short-duration induced over voltage withstand test (ACSD)
  • 11.5 Long-duration induced AC voltage withstand test (ACLD)
  • 11.6 Induced over voltage withstand test of dry-type transformer
  • 12 Partial discharge measurement (routine test)
  • 13 Measurement of no-load loss and current (routine test)
  • 14 Measurement of short-circuit impedance and load loss (routine test)
  • 15 On-load tap-changer test (routine test)
  • 15.1 Operation test
  • 15.2 Auxiliary circuits insulation test
  • 16 Temperature rise test (type test)
  • 17 Mechanical strength test of oil tank (type test)
  • 17.1 Test purpose
  • 17.2 Test methods
  • 17.3 Judgment of results
  • 17.4 Precautions
  • 18 Determination of sound levels (special test)
  • 19 Measurement of zero-sequence impedance of three-phase transformer (special test)
  • 19.1 General
  • 19.2 Measurement of zero-sequence impedance with balanced ampere turns
  • 19.3 Measurement of zero-sequence impedance without balanced ampere turn
  • 20 Test on ability to withstand short circuit (special test)
  • 21 Measurement of no-load current harmonic (special test)
  • 22 Measurement of power absorbed by fan and oil pump motor (special test)
  • 22.1 Preparation before test
  • 22.2 Test methods
  • 22.3 Precautions

1 Scope

This standard specifies procedures and methods of routine tests, type tests and special tests for oil-immersed type and dry-type power transformers.

This standard applies to the tests of oil-immersed type and dry-type power transformers.

This standard may apply to special transformers.

2 Normative references

The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding any corrigendum), or revisions of, any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the latest editions of the standards indicated below. For undated references, the latest edition of the document referred to applies.

GB/T 311.6-1983 High voltage test techniques - Part 5: Sphere-gaps for voltage measurement (eqv IEC 60052:1960)

GB/T 507-2002 Insulating liquids - Determination of the breakdown voltage at power frequency (eqv IEC 60156:1995)

GB 1094.1-1996 Power transformers - Part 1: General (eqv IEC 60076-1:1993)

GB 1094.2-1996 Power transformers - Part 2: Temperature rise (eqv IEC 60076-2:1993)

GB 1094.3-2003 Power transformers - Part 3:Insulation levels, dielectric tests and external clearances in air (eqv IEC 60076-3:2000)

GB/T 1094.4-2005 Power transformers - Part 4:Guide to the lightning impulse and switching impulse testing - Power transformers and reactors (IEC 60076-4:2002, MOD)

GB 1094.5 Power transformers - Part 5: Ability to withstand short circuit (GB 1094.5-2003, IEC 69076-5:2000, MOD)

GB/T 1094.10 Power transformers - Part 10: Determination of sound levels (GB/T 1094.10-2003, IEC 60076-10:2001, MOD)

GB/T 5654-1985 Measurement of relative permittivity, dielectric dissipation factor at power frequency and volume resistivity of insulating liquids

GB 6450 Dry-type power transformers (GB 6450-1986, eqv IEC 60726:1982)

GB/T 6451-19 Specification and technical requirements for three-phase oil-immersed power transformers

GB 7597-1987 Method of sampling for transformer and turbine oils in electric power industry

GB/T 7600-1987 Determination of water content in transformer oils in service by coulometric method

GB/T 7601-1987 Determination of water content in transformer oils in service by gas chromatographic method

GB/T 10228-1997 Specification and technical requirements for dry-type power transformers

GB/T 16274-1996 Specification and technical requirements for oil immersed power transformers 500kV

GB/T 16927.1-1997 High voltage test techniques - Part 1: General test requirements (eqv IEC 60060-1:1989)

GB/T 17623-1998 Determination of componental contents of gases dissolved in insulating oil by gas chromatography method

DL/T 423-1991 Determination of air content in insulating oil by vacuum differential pressure method

3 Main symbols

Ur - rated voltage, V;

Ir - rated current, A;

Sr - rated power, kVA;

K - voltage ratio;

R - resistance, ohm;

T - temperature, °C;

Rxg - phase resistance, ohm;

Rxn - line resistance, ohm;

Kdelta - air density correction factor;

Kd - air density;

fr - rated frequency, Hz;

P0 - no-load loss, W ;

I0 - no-load current, %;

Pk - load loss corrected to reference temperature, W;

Zk - short-circuit impedance corrected to reference temperature, %;

Zi - short-circuit impedance, ohm;

Pr - resistance loss, W;

thetap - average temperature, °C;

deltatheta - temperature rise, K;

Z0 - zero sequence impedance, ohm/phase;

Zs - system impedance, ohm.

4 Test procedure

This test procedure is not standardized. The items with the test type not indicated are routine tests.

To be specific, the following items are included.

a) Strength test of oil tank (type test);

b) Oil tank leak test;

c) Measurement of dielectric characteristics:

1) Determinations of insulation resistance, absorption ratio and polarization index (for transformers of 35kV, 4,000kVA and above, 66kV and above, the insulation resistance and absorption ratio shall be given; for those of 330kV and above, the insulation resistance value, absorption ratio and polarization index shall be given; for other small and medium-sized transformers, only the insulation resistance value is given);

2) Measurement of dielectric dissipation factor (for those of 35kV, 8,000kVA and above, and 66kV and above).

d) Transformer oil test:

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 40 pages — is available in the English PDF.

Referenced standards

Cited by

Similar standards

Editions of JB/T 501

EditionTitleRevisionStatus
JB/T 501-2006Test guide for power transformerscurrent editionCurrent
JB/T 501-1991Test guide for power transformersprevious editionSuperseded

This page sells the current edition, JB/T 501-2006. Earlier editions are listed for reference only.

How to Download JB/T 501-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
40 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 501-2006

$470.00