JB/T 11167.3-2011AC long-length submarine cables with cross-linked polyethylene insulation and their accessories for rated voltages from 10 kV (Um=12 kV) up to 110 kV (Um=126 kV) - Part 3: Accessories (English PDF)
额定电压10kV(Um=12kV)至110kV(Um=126kV)交联聚乙烯绝缘大长度交流海底电缆及附件 第3部分:额定电压10kV(Um=12kV)至110kV(Um=126kV)交联聚乙烯绝缘大长度交流海底电缆附件
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 11167.3-2011 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
May 18, 2011
Implementation date
August 1, 2011
Scope
JB/T 11167.3-2011 is the English-translated version of 额定电压10kV(Um=12kV)至110kV(Um=126kV)交联聚乙烯绝缘大长度交流海底电缆及附件 第3部分:额定电压10kV(Um=12kV)至110kV(Um=126kV)交联聚乙烯绝缘大长度交流海底电缆附件.
JB/T 11167.3-2011 is Part 3, on accessories, of the recommended Chinese machinery industry standard for long-length AC submarine cables with cross-linked polyethylene insulation rated from 10 kV (Um = 12 kV) up to 110 kV (Um = 126 kV).
It covers terms and definitions, service characteristics, product designation, technical requirements, the marking of accessories, the tests and the requirements they have to meet, inspection rules, packaging, transport and storage.
The accessories it names are factory joints, also called soft joints, repair joints, outdoor terminations and GIS terminations. It adds that, where the cable project allows, other product types tested to GB/T 12706.4-2008 may serve as outdoor terminations and repair joints from 10 kV to 35 kV. Among the standards it quotes are JB/T 11167.1-2011 and JB/T 11167.2-2011.
Found what you need?
Document preview — JB/T 11167.3-2011
National Standard of the People's Republic of China
- ICS
- 29.060.20
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- [Preview only]
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Technical requirements
- 4.1 General requirements
- 4.2 Model designation
- 6 Test methods
- 6.1 Factory inspection
- 6.2 Type inspection
- 7 Inspection rules
- 8 Marking, packaging, transportation and storage
- 8.1 Marking
- 8.2 Packaging
1 Foreword
JB/T 11167.3-2011 was issued by Ministry of Industry and Information Technology of the People's Republic of China on 18 May 2011 and has been in force since 1 August 2011.
It is one of 3 parts of the JB/T 11167 series.
The JB/T prefix marks a recommended standard. It is not law in itself: it becomes binding when a contract names it, when a regulation or a mandatory standard refers to it, or when a producer declares conformity with it.
2 Scope Preview
This standard is Part 3, on accessories, of the recommended Chinese machinery industry standard for long-length AC submarine cables with cross-linked polyethylene insulation rated from 10 kV (Um = 12 kV) up to 110 kV (Um = 126 kV). It covers terms and definitions, service characteristics, product designation, technical requirements, the marking of accessories, the tests and the requirements they have to meet, inspection rules, packaging, transport and storage. The accessories it names are factory joints, also called soft joints, repair joints, outdoor terminations and GIS terminations. It adds that, where the cable project allows, other product types tested to GB/T 12706.4-2008 may serve as outdoor terminations and repair joints from 10 kV to 35 kV. Among the standards it quotes are JB/T 11167.1-2011 and JB/T 11167.2-2011.
JB/T 11167.3-2011 falls under ICS 29.060.20, in the field of electrical engineering.
This catalogue holds 619 other JB/T standards in that field.
In this catalogue, JB/T standards carry edition years from 1967 to 2026.
3 Normative references
GB/T 772-2005 — Technical specifications of porcelain element for high voltage insulators
GB/T 3048.8-2007 — Test methods for electrical properties of electric cables and wires - Part 8: AC Voltage test
GB/T 3048.11-2007 — Test methods for electrical properties of electric cables and wires - Part 11: Test for dielectric dissipation factor
GB/T 3048.12-2007 — Test methods for electrical properties of electric cables and wires - Part 12: Partial discharge test
GB/T 3048.13-2007 — Test methods for electrical properties of electric cables and wires - Part 13: Impulse voltage test
GB/T 4423-2007 — Copper and copper-alloy cold-drawn rod and bar
GB/T 8287.1-2008 — Indoor and outdoor post insulators for systems with nominal voltage greater than 1000 V -- Part 1: Test on insulators of ceramic material or glass
GB/T 12464-2002 — Wooden boxes
GB/T 12706.4-2008 — Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV)
GB/T 26218.1-2010 — Selection and dimensioning of high-voltage insulators intended for use in polluted conditions -- Part 1: Definitions, information and general principles
GB/T 26218.2-2010 — Selection and dimensioning of high-voltage insulators intended for use in polluted conditions -- Part 2: Ceramic and glass insulators for a.c. systems
JB/T 11167.1-2011 — Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage from 10kV (Um=12kV) up to 110kV(Um=126kV) - Part 1: Test methods and requirements
JB/T 11167.2-2011 — AC long-length submarine cables with cross-linked polyethylene insulation and their accessories for rated voltages from 10 kV (Um=12 kV) up to 110 kV (Um=126 kV) - Part 2: Cables
YD/T 814.3-2005 — Closure for optical fiber cables. Part 3: Clousure for shallow water submarine optical fiber cables
IEC 62271 -209-2007
4 Where this standard sits
It cites 15 standards, among them GB/T 772-2005, GB/T 3048.8-2007, GB/T 3048.11-2007, listed in full above.
It is one part of the JB/T 11167 series, of which this catalogue holds 3 parts.
5 About this standard
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
English translation: about 15 pages
6 Related standards
Other parts of this standard:
JB/T 11167.1-2011 — Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage from 10kV (Um=12kV) up to 110kV(Um=126kV) - Part 1: Test methods and requirements
JB/T 11167.2-2011 — Part 2: Cables
Standards on related subjects:
JB/T 10696.9-2011 — Test methods for mechanical, physical and chemical properties of electric cables and wires - Part 9: Termite test
GB/T 12528-2008 — Rail vehicle cables with rated voltages up to and including 3kV
GB 12528.11-2003 — Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV Amendment 1: Cross-linked polyolefin insulated cables (wires) for railway vehicles
JB/T 14660-2024 — Rubber-insulated flexible cable for underground tunneling equipmentwith rated voltage from 6 kV to 30 kV
7 Classification and status
International classification (ICS): 29.060.20
Prefix JB/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 772-2005Technical specifications of porcelain element for high voltage insulators
- GB/T 3048.8-2007Test methods for electrical properties of electric cables and wires - Part 8: AC voltage test
- GB/T 3048.11-2007Test methods for electrical properties of electric cables and wires — Part 11: Test for dielectric dissipation factor
- GB/T 3048.12-2007Test methods for electrical properties of electric cables and wires - Part 12: Partial discharge test
- GB/T 3048.13-2007Test methods for electrical properties of electric cables and wires — Part 13: Impulse voltage test
- GB/T 4423-2007Copper and copper alloy cold-drawn rod and bar
IEC 62271 -209-2007
Similar standards
How to Download JB/T 11167.3-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12464-2002 — Wooden boxes
GB/T 12706.4-2008 — Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV)
GB/T 26218.1-2010 — Selection and dimensioning of high-voltage insulators intended for use in polluted conditions -- Part 1: Definitions, information and general principles
JB/T 11167.3-2011
$389.00