GB/T 41629.2-2022Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV)—Part 2: Long AC submarine cables (English PDF)
额定电压500 kV(Um=550 kV)交联聚乙烯绝缘大长度交流海底电缆及附件 第2部分:大长度交流海底电缆
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for GB/T 41629.2-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 11, 2022
Implementation date
February 1, 2023
Scope
GB/T 41629.2-2022 is the English-translated version of 额定电压500 kV(Um=550 kV)交联聚乙烯绝缘大长度交流海底电缆及附件 第2部分:大长度交流海底电缆.
GB/T 41629.2-2022 is Part 2 of GB/T 41629 and deals with the long-length AC submarine cable itself, insulated with cross-linked polyethylene, for a rated voltage of 500 kV (Um = 550 kV).
It fixes the service characteristics, the product code, model, specification and designation, the cable materials and construction, the marking and requirements of the finished cable, the acceptance rules, shipping and storage, and the test after laying.
Its tables give the types and specifications of submarine cable, the nominal thicknesses of insulation, lead sheath and inner sheath, the identification colour code and the routine, sampling and type test items, the optical fibre unit included.
It applies to cables laid and worked under the sea, fibre optic composite ones included, and cites GB/T 41629.1-2022 among others. It was issued on 11 July 2022 and has applied since 1 February 2023.
Found what you need?
Document preview — GB/T 41629.2-2022
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Use feature
- 5 Product code, model, specification and product representation
- 6 Cable material and construction
- 7 Finished cable marking
- 8 Finished cable requirements
- 9 Acceptance Rules
- 10 Shipping and Storage
- 11 Test after laying
- Appendix A (Informative) Properties of Cross-Linked Polyethylene Insulating Materials
- Appendix B (Informative) Properties of Semiconductive Shielding Materials
- Appendix C (Informative) Properties of Semiconductive Sheathing Compounds and Wrapping Tapes
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
This document is Part 2 of GB/T 41629 "rated voltage 500kV (Um=550kV) XLPE insulated long-length AC submarine cables and accessories".
GB/T 41629 has released the following parts.
--- Part 1: Test methods and requirements;
--- Part 2: Large-length AC submarine cables;
--- Part 3: Submarine cable accessories.
This document is proposed by China Electrical Equipment Industry Association.
This document is under the jurisdiction of the National Standardization Technical Committee of Wires and Cables (SAC/TC213).
Introduction
Submarine cables are widely used in offshore wind power transmission, island power supply, and offshore platform power supply and distribution. Compared with onshore cables, submarine power The cable has the characteristics of complex product structure, high protection requirements, and special grounding methods. GB/T 41629 is rated voltage 500kV submarine cable Product standards for submarine cables and accessory systems, including the naming rules, test methods, technical requirements, etc. of submarine cables and accessory systems, consisting of the following 3 composed of parts.
--- Part 1: Test methods and requirements. The purpose is to unify the test and technology of the rated voltage 500kV submarine cable and accessory system. technical requirements.
--- Part 2: Large-length AC submarine cables. The purpose is to unify the structural parameters and basic parameters of the rated voltage 500kV submarine cable. performance requirements.
--- Part 3: Submarine cable accessories. The purpose is to unify the structural parameters and basics of the rated voltage 500kV submarine cable accessories can request.
1 Scope
This document specifies the rated voltage 500kV (Um=550kV) XLPE insulated long-length AC submarine cable (the following submarine electricity Cable refers to the type, material, technical requirements, test, acceptance rules, shipment, storage and transportation of AC submarine cables).
This document is applicable to the XLPE insulation with rated voltage of 500kV (Um=550kV) used under subsea laying and operating conditions. Length AC submarine cable (including fiber optic composite).
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB/T 2951.11-2008 General test methods for insulating and sheathing materials of electrical and optical cables - Part 11: General test methods Thickness and Outline Dimensions Measurement Mechanical Properties Test
GB/T 3956-2008 Conductor of cables
GB/T 6995.1 Wire and Cable Identification Marking Method Part 1: General Provisions
GB/T 6995.2 Wire and Cable Identification Marking Method Part 2: Standard Colors
GB/T 9771 (all parts) single-mode optical fiber for communication
GB/T 12357 (all parts) Multimode optical fibers for communication
GB/T 15972.40-2008 Specification for test methods for optical fibers - Part 40: Measurement methods and tests for transmission and optical properties Program decay
GB/T 15972.42-2021 Specification for test methods for optical fibers - Part 42: Measurement methods and test procedures for transmission characteristics Wavelength Dispersion
GB/T 41629.1-2022 Rated voltage 500kV (Um=550kV) XLPE insulated long-length AC submarine cables and Annex Part 1: Test Methods and Requirements
JB/T 8996 Guidelines for selection of high voltage cables
3 Terms and Definitions
The terms and definitions defined in GB/T 41629.1-2022 and the following apply to this document.
3.1 Approximate value
A value that is neither guaranteed nor checked.
Note: Approximate values are usually used in the calculation of other dimension values.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2951.11-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
- GB/T 3956-2008Conductors of insulated cables
- GB/T 6995.1Markings for electric wires and cables - Part 1: General requirements
- GB/T 6995.2Markings for electric wires and cables - Part 2: Standard colours
- GB/T 12357Multimode optical fibres for telecommunication - Part 1: Sectional specification for category A1 multimode fibres
- GB/T 15972.40-2008Specifications for optical fibre test methods - Part 40: Measurement methods and test procedures for transmission characteristics - Attenuation
GB/T 9771
Cited by
- GB/T 41629.1-2022Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV)—Part 1: Test methods and requirements
- GB/T 41629.3-2022Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV)—Part 3: Accessories for submarine cables
Similar standards
How to Download GB/T 41629.2-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12357.1-2024 — Multimode optical fibres for telecommunication - Part 1: Sectional specification for category A1 multimode fibres
GB/T 12357-1990 — Multimode optical fibres for telecommunication - Part 1: Sectional specification for category A1 multimode fibres
GB/T 12357.2-2004 — Multimode optical fibres for telecommunication -- Part 2: Sectional specification for category A2 multimode fibres
Secure payment via Stripe
Payments accepted
GB/T 41629.2-2022