JB/T 11167.1-2011Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage from 10kV (Um=12kV) up to 110kV(Um=126kV) - Part 1: Test methods and requirements (English PDF)
额定电压10kV(Um=12kV)至110kV(Um=126kV)交联聚乙烯绝缘大长度交流海底电缆及附件 第1部分:试验方法和要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 11167.1-2011 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
May 18, 2011
Implementation date
August 1, 2011
Scope
JB/T 11167.1-2011 is the English-translated version of 额定电压10kV(Um=12kV)至110kV(Um=126kV)交联聚乙烯绝缘大长度交流海底电缆及附件 第1部分:试验方法和要求.
JB/T 11167.1-2011 is a recommended Chinese machinery industry standard and the first part of the series on long alternating-current submarine cables with cross-linked polyethylene insulation and their accessories, for rated voltages from 10 kV (Um = 12 kV) up to 110 kV (Um = 126 kV).
This part gives the test methods and the requirements for those cables and accessories. It applies to single-core and three-core XLPE submarine cables from 10 kV to 110 kV and to optical fibre composite XLPE submarine cables, and it reaches factory-made accessories too, among them soft joints, repair joints and terminations.
Among the standards it quotes are GB/T 2951.11-2008, GB/T 2951.13-2008, GB/T 2951.21-2008, GB/T 3048.12-2007, GB/T 3956-2008, GB/T 16927.1-1997 and JB/T 11167.2-2011. Its classifications are K13 and 29.060.20.
Found what you need?
Document preview — JB/T 11167.1-2011
National Standard of the People's Republic of China
- ICS
- 29.060.20
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword
- Scope
- Normative references
- About this standard
- Related standards
- Classification and status
1 Foreword
JB/T 11167.1-2011 was issued by MIIT on 18 May 2011 and has been in force since 1 August 2011.
It is one of 3 parts of the JB/T 11167 series.
2 Scope
This standard is a recommended Chinese machinery industry standard and the first part of the series on long alternating-current submarine cables with cross-linked polyethylene insulation and their accessories, for rated voltages from 10 kV (Um = 12 kV) up to 110 kV (Um = 126 kV). This part gives the test methods and the requirements for those cables and accessories. It applies to single-core and three-core XLPE submarine cables from 10 kV to 110 kV and to optical fibre composite XLPE submarine cables, and it reaches factory-made accessories too, among them soft joints, repair joints and terminations. Among the standards it quotes are GB/T 2951.11-2008, GB/T 2951.13-2008, GB/T 2951.21-2008, GB/T 3048.12-2007, GB/T 3956-2008, GB/T 16927.1-1997 and JB/T 11167.2-2011. Its classifications are K13 and 29.060.20.
3 Normative references
JB/T 11167.1-2011 cites the following standards, which apply in full or in part through the references made to them in its clauses.
GB/T 2951.11-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
GB/T 2951.12-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 12: Methods for general application -- Thermal ageing methods
GB/T 2951.13-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 13: Methods for general application -- Measurement for determining the density -- Water absorption tests -- Shrinkage test
GB/T 2951.21-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 21: Methods specific to elastomeric compounds -- Ozone resistance, hot set and mineral oil immersion tests
GB/T 2951.31-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 31: Methods specific to PVC compounds -- Pressure test at high temperature -- Test for resistance to cracking
GB/T 3048.12-2007
GB/T 3048.13-2007
GB/T 3956-2008 — Conductors of insulated cables
GB/T 16927.1-1997
JB/T 11167.2-2011 — AC long-length submarine cables with cross-linked polyethylene insulation and their accessories for rated voltages from 10 kV (Um=12 kV) up to 110 kV (Um=126 kV) - Part 2: Cables
4 About this standard
Issued by: MIIT
English translation: about 15 pages
5 Related standards
Other parts of this standard:
JB/T 11167.2-2011 — AC long-length submarine cables with cross-linked polyethylene insulation and their accessories for rated voltages from 10 kV (Um=12 kV) up to 110 kV (Um=126 kV) - Part 2: Cables
JB/T 11167.3-2011 — AC long-length submarine cables with cross-linked polyethylene insulation and their accessories for rated voltages from 10 kV (Um=12 kV) up to 110 kV (Um=126 kV) - Part 3: Accessories
6 Classification and status
International classification (ICS): 29.060.20
Prefix JB/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2951.11-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
- GB/T 2951.12-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 12: Methods for general application -- Thermal ageing methods
- GB/T 2951.13-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 13: Methods for general application -- Measurement for determining the density -- Water absorption tests -- Shrinkage test
- GB/T 2951.21-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 21: Methods specific to elastomeric compounds -- Ozone resistance, hot set and mineral oil immersion tests
- GB/T 2951.31-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 31: Methods specific to PVC compounds -- Pressure test at high temperature -- Test for resistance to cracking
- GB/T 3048.12-2007Test methods for electrical properties of electric cables and wires - Part 12: Partial discharge test
Cited by
- NB/T 31117-2017Guide for selection and laying of AC submarine cables for offshore wind power projects
- JB/T 11167.2-2011AC long-length submarine cables with cross-linked polyethylene insulation and their accessories for rated voltages from 10 kV (Um=12 kV) up to 110 kV (Um=126 kV) - Part 2: Cables
- JB/T 11167.3-2011AC long-length submarine cables with cross-linked polyethylene insulation and their accessories for rated voltages from 10 kV (Um=12 kV) up to 110 kV (Um=126 kV) - Part 3: Accessories
Similar standards
How to Download JB/T 11167.1-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2951.11-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
GB/T 2951.12-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 12: Methods for general application -- Thermal ageing methods
GB/T 2951.13-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 13: Methods for general application -- Measurement for determining the density -- Water absorption tests -- Shrinkage test
Secure payment via Stripe
Payments accepted
JB/T 11167.1-2011