Scope

GB/T 8287.1-2008 is the English-translated version of 标称电压高于1000V系统用户内和户外支柱绝缘子 第1部分:瓷或玻璃绝缘子的试验.

GB/T 8287.1-2008 — This standard applies to AC nominal voltage above 1000V, no more than 100Hz frequency electrical installations or equipment users and outdoor post insulators of ceramic or glass components.

Found what you need?

Document preview — GB/T 8287.1-2008

National Standard of the People's Republic of China

ICS
29.080.10
Classification
K 48
Replacing
GB 12744-1991; GB 8287.1-1998

Issued by: Standardization Administration of China

Contents

  • Introduction
  • 1 General
  • 1.1 Purpose and Scope
  • 1.2 Normative references
  • 1.3 Terms and Definitions
  • 2 Insulator
  • 2.1 Insulator material and insulator
  • 2.2 Characteristics of the value of the post insulator
  • 2.3 Insulator mark
  • 3 Classification test, sampling rules and procedures
  • 3.1 Test Category
  • 3.2 Quality Management
  • 3.3 General requirements for type testing
  • 3.4 General requirements for sampling test
  • 4 Electrical Test Procedure
  • 4.1 General requirements for high-voltage test of
  • 4.2 Standard atmospheric conditions and electrical testing correction factor
  • Artificial rain wet test parameters 4.3
  • 4.4 Electrical test mounting arrangements
  • 4.5 Dry lightning impulse withstand voltage test --- type test
  • 4.6 Impulse withstand voltage wet or dry type test test ---
  • 4.7 Power frequency dry withstand voltage test --- type test (only for indoor post insulators)
  • 4.8 Power frequency wet withstand voltage test --- type test (only for outdoor post insulators)
  • 4.9 Artificial pollution withstand voltage test --- type test (only for outdoor post insulators)
  • 4.10 Breakdown test --- test sample
  • 4.11-by-11 electrical test
  • 5 Machinery and other test procedures
  • Check --- size 5.1 type test and sampling test
  • 5.2 Mechanical failing load test and sampling test 12 Type ---
  • 5.3 Offset test under a load of special type test ---
  • 5.4 Temperature cycling test --- test sample
  • 5.5-by thermal shock test (only for glass insulators)
  • 5.6 Porosity test --- test sample (applies only to post insulators)
  • 5.7 Galvanized layer test
  • 5.8-by-15 visual inspection
  • 5.9-by-15 Mechanical tests
  • 5.10-by-16 ultrasonic flaw inspection
  • 6 Post insulators 17 pilot projects
  • 6.1 Type tests
  • 6.2 Sampling Test
  • 6.3-by-17 test
  • 6.4 Summary 18 post insulators pilot project
  • The shape and position deviation test methods in Appendix A (informative) post insulator

Foreword

GB/T 8287 "nominal voltage greater than 1000V system and outdoor post insulators" currently consists of two parts.

--- Part 1. Test porcelain or glass insulators;

--- Part 2. Dimensions and characteristics.

This section GB/T 18287 Part of.

The partial modification of the use of IEC 60168:2001 "nominal voltage greater than 1000V system and outdoor post insulators of porcelain or glass Test "(in English).

This section and the IEC 60168:2001 technical differences in terms of which they are involved in the margin of a single vertical line identification, Appendix C gives the list of technical differences and their causes, given in Appendix D of this section and the IEC 60168:2001 clauses table.

For ease of use, this section also made the following editorial changes.

a) "this International Standard" be replaced by "this section";

b) use a decimal point instead of a decimal point ",". ",";

c) Remove the preface to international standards and references.

This section consolidates and replaces GB 12744-1991 "Fog type outdoor post insulators of ceramic rod" portion and technical conditions GB 8287.1-1998. Content "High voltage post insulators of the first part of the technical conditions".

The main difference between this part and GB 8287.1-1998 include.

--- Text format, layout, and other clauses in full accordance with IEC 60168:2001, and GB 8287.1-1998 is completely different;

--- The main characteristics of post insulators characterized by a rated voltage to impulse voltage;

--- The number of samples from the original mechanical type test of three to one;

--- Sampling test rules and procedures in accordance with IEC system, no longer used the piece of secondary test procedures. If the number of the test is greater than or equal to 3 when mechanical failure test is no longer using AQL = 2.5% of the measured secondary test procedures;

--- Although the stack-mounted cylindrical post insulators rarely used in our country, but considering the inclusion of such insulators IEC 60168, in order to to maintain the integrity of the standard text of this part it is still included in this type of insulator;

--- Canceled expressed in GB 8287.1-1998 II grade product not creepage distance limit prescribed;

Porosity Test --- methine dye in methanol or ethanol fuel ethanol solution changed from magenta;

Scope --- this section extends to the UHV to adapt to the development of UHV products.

This part of the Annex A, Annex B, Annex C and Annex D are informative appendices.

This part is proposed by the China Electrical Equipment Industrial Association.

The insulators in part by the National Standardization Technical Committee (SAC/TC80) centralized.

This part mainly drafted by. West An Shuangjia high-voltage ceramic Electric Co., Ltd., Xi'an Institute of electrical porcelain, high-voltage Tangshan Co., Suzhou Electric Porcelain Co., Ltd., Xi'an high-voltage electrical porcelain limited liability company, the National Insulator arrester Quality Supervision and Inspection Center.

1 General

1.1 Purpose and Scope

This section GB/T 8287 is suitable for AC nominal voltage above 1000V, not more than 100Hz frequency electrical devices or equipment Indoor and outdoor post insulators and ceramic or glass element.

DC system with post insulator can be performed with reference to this section.

This section does not apply to composite insulators for indoor post insulators or organic material.

The purpose of this section is.

--- Definitions of the terms used;

--- Provisions electrical and mechanical characteristics of post insulators;

--- Predetermined characteristic values \u200b\u200bof validation criteria;

--- Specified test methods;

--- Specified acceptance criteria.

Post insulators characteristic values \u200b\u200bspecified in GB/T 8287.2-2008 in.

This section does not include the special operating conditions of post insulators selection requirements.

Note 1. filthy conditions insulator selection see IEC 60815.

Note 2. This section does not include radio interference tests, the test methods, see JB/T 3567-1999.

Note 3. if the section is used to hollow post insulator, should also consider the requirements of IEC 62155.

1.2 Normative references

The following documents contain provisions which, through reference to GB/T 8287 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB 311.1-1997 insulation with high voltage power transmission equipment (neqIEC 60071-1.1993) GB/T 494-1998 Building bitumen GB/T 2900.8 Electrotechnical terminology insulator (GB/T 2900.8-1995, modIEC 60050-471) GB/T 4585-2004 high-voltage insulators for ac systems - Artificial pollution tests (IEC 60507:1991, IDT) GB/T 8411.1-2008 ceramic and glass insulating materials - Part 1. Definitions and classification (IEC 60672-1:1995, MOD) GB/T 8411.3-2008 ceramic and glass insulating materials - Part 3. material properties (IEC 60672-3:1997, MOD) GB/T 8287.2-2008 nominal voltage greater than 1000V system and outdoor post insulators - Part 2. Dimensions and Characteristics (IEC 60273:1990, MOD) GB/T 16927.1-1997 high voltage test techniques - Part 1. General test requirements (eqv IEC 60060-1. 1989) GB/T 19001 quality management system requirements (GB/T 19001-2000, idt ISO 9001:2000) JB/T 3567-1999 Test method for high-voltage insulators radio interference (modIEC 60437.1997) JB/T 4307-2004 insulators fitted with rubber cement glue

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

Cited by

How to Download GB/T 8287.1-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 8287.1-2008

$515.00