GB/T 44179-2024Composite hollow core station post insulators with a. c. voltage greater than 1 000 V and d. c. voltage greater than 1 500 V - Definitions, test methods and acceptance criteria (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for GB/T 44179-2024 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

July 24, 2024

Implementation date

February 1, 2025

Scope

GB/T 44179-2024 (Composite hollow core station post insulators with a. c. voltage greater than 1 000 V and d. c. voltage greater than 1 500 V - Definitions, test methods and acceptance criteria) is available as an English-translated PDF.

GB/T 44179-2024 — This document applies to hollow post composite insulators for power stations, which are hollow insulating tubes, insulating the hollow post composite insulator for power stations defined in this document is composed of filling material, umbrella cover made of silicone rubber material and end metal accessories.

Generally used for outdoor or indoor operation at an AC voltage higher than 1000V or a DC voltage higher than 1500V. environment. The purpose of this document is to. ---Define the terms used; ---Specify the test method; ---Specify acceptance criteria.

This document does not specify the characteristic tests of electrical equipment of which hollow post composite insulators for station use may ultimately become components.

Found what you need?

Document preview — GB/T 44179-2024

National Standard of the People's Republic of China

ICS
29.080.10
Classification
K 48

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Graphics and Logos
  • 5 Environmental conditions
  • 6 Transport, storage and installation information
  • 7 Test Classification
  • 7.1 General Principles
  • 7.2 Design of Experiment
  • 7.3 Type test
  • 7.4 Sampling test
  • 7.5 Test by test
  • 8 Designing an experiment
  • 8.1 General
  • 8.2 Interface and end fitting connection test
  • 8.3 Core load test after assembly
  • 8.4 Umbrella and umbrella cover material test
  • 8.5 Pipe material test
  • 8.6 Water diffusion test with umbrella cover
  • 9 Type test
  • 9.1 Internal pressure test
  • 9.2 Bending test
  • 9.3 Specified tensile load test, compression and flexural endurance test
  • 9.4 Electrical test
  • 10 Sampling test
  • 11 Test one by one 13
  • 11.1 General
  • 11.2 Appearance inspection
  • 11.3 Seal test
  • 12 File
  • Appendix A (Informative) Load Definition, Load Relationship
  • Reference
  • Table 1 Design and type test requirements
  • Figure A.1 Load definition and load relationship in GB/T 25096-2010
  • Figure A.2 Load definitions and load relationships in GB/T 21429-2008
  • Figure A.3 Relationship of bending load
  • Figure A.4 Load definition and load relationship comparison diagram

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is modified to adopt IEC 62772:2023 "Air conditioners for substations with AC voltages above 1000V and DC voltages above 1500V" Definitions, test methods and acceptance criteria for core-post composite insulators.

The technical differences between this document and IEC 62772:2023 and their reasons are as follows.

a) GB/T 22079 replaces IEC 62217 (see Chapter 5, Chapter 6, and Chapter 8) to adapt to my country's technical conditions;

b) GB/T 25096-2010 replaced IEC 62231:2006 (see 7.3, 8.3.2.1, 9.3) to adapt to my country's technical conditions;

c) The line "Coupling agent and application method" in the interface (see Table 1 of IEC 62772:2023) has been deleted to adapt to the actual situation in my country;

d) Change "hydrophobic migration test" to "hydrophobic test" (see Table 1, 8.4.5), and change "see IEC TR62039" to "according to GB/T 22079" (see 8.4.5) to adapt to the actual test technical conditions in my country;

e) The qualifier that the mechanical type of hollow post composite insulators is determined by the "height" characteristic has been deleted. "Only for compression and flexural resistance Load test" (see 7.3 of IEC 62772:2023), other mechanical properties are also affected to varying degrees by the "height" characteristics;

f) "The manufacturer shall specify the SML value of the test piece" (see 8.2.2 of IEC 62772:2023) has been deleted and has been added to the drawings and markings (see 4 the necessary parameter values need to be provided in the chapter;

g) Added normative reference GB/T 18851.1-2012 (see 8.3.1.2, 8.3.2.1) to provide standard for dye penetration test method.

quasi basis;

h) GB/T 19519-2014 replaced IEC 61109 (see 8.3.1.2, 8.3.2.1) to adapt to my country's technical conditions;

i) Added "If the products are of equal diameter, only one sample shall be tested" (see 8.3.1.2, 8.3.2.1 and 8.3.3.1) to accommodate the actual situation in our country;

j) Added "tracking and corrosion resistance test for umbrella cover materials" (see 8.4.6) to assess the relevant performance of umbrella and umbrella cover materials;

k) Deleted the following. "Theoretical calculation may replace the specified tensile load test, compression and flexural endurance test after agreement between the supplier and the buyer" (see 9.3 of IEC 62772:2023) to adapt to the actual situation in my country;

l) GB/T 8287.1-2008 replaced IEC 60168 (see 9.4.2~9.4.6) to adapt to my country's technical conditions;

m) Deleted "If applied to a DC system, the DC voltage test shall be substituted for the AC voltage test" (see IEC 62772:2023 9.4.5 and 9.4.6), which description already appears in the general provisions (see 9.4.1);

n) Added technical content of appearance inspection (see 11.2) to adapt to the actual situation in my country.

The following editorial changes were made to this document.

a) Added necessary parameter values in Chapter 4 Drawings and Markings, such as SML, MML, MDCL, MDToL, STL, MSP, etc.

Body description;

b) Change the general technical description of hollow post composite insulator assembly components in Figure 1 from footnote 1 to footnote 6 to footnote 1 to footnote 6.

Note 4.

c) Added a note in 8.5.3 Water diffusion test to explain the scope of water diffusion test samples;

d) Deleted Appendix A (informative) "Filling material identification" and Appendix C (informative) "Hollow pillar composite insulation" of IEC 62772:2023 "Schematic diagram of sub-assembly components";

e) The informative references GB/T 311.1-2012 and GB/T 8287.2-2008 were added to the references.

Introduction

The hollow post composite insulator for power stations is composed of a protective silicone rubber umbrella and an insulating hollow tube that bears mechanical loads.

The mechanical load is transferred to the tube by the end fittings. The interior of the hollow tube is completely filled with insulating material and the tube is made of resin impregnated fiber.

In substations, power station hollow post composite insulators are used as typical post insulators. Insulator materials and interfaces are based on GB/T 22079 conducts design tests. Some tests are classified as "design tests". These tests only need to be performed on insulators of the same design.

All design tests for hollow post composite insulators for power stations shall be carried out in accordance with the general provisions of GB/T 22079.

In terms of the design test, the time effect on the overall power station hollow post composite insulator and its components (tube material, umbrella cover, interface, etc.) to ensure a satisfactory service life under normal stress operating conditions.

This document involves GB/T 21429-2008 and GB/T 25096-2010.

Silicone rubber sheath materials with hydrophobicity and hydrophobicity migration properties (HTM) are preferred for hollow post composite insulators used in power stations.

Silicone rubber is a widely recognized effective method to protect against severe pollution.

The salt spray test specified in GB/T 22079 is used to quantify the hydrophobic migration characteristics.

The hollow post composite insulator for power stations can be used in both AC and DC systems.

Tracking and erosion tests are used to determine the minimum requirements for resistance of a material to tracking and erosion.

AC voltage higher than 1000V and DC voltage higher than 1500V hollow post composite insulator for substation Definitions, test methods and acceptance criteria

1 Scope

This document applies to hollow post composite insulators for power stations, which are hollow insulating tubes, insulating the hollow post composite insulator for power stations defined in this document is composed of filling material, umbrella cover made of silicone rubber material and end metal accessories.

Generally used for outdoor or indoor operation at an AC voltage higher than 1000V or a DC voltage higher than 1500V.

environment.

The purpose of this document is to.

---Define the terms used;

---Specify the test method;

---Specify acceptance criteria.

This document does not specify the characteristic tests of electrical equipment of which hollow post composite insulators for station use may ultimately become components.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.

GB/T 8287.1-2008 Indoor and outdoor post insulators for systems with nominal voltages above 1000V Part 1: Porcelain or glass Tests on insulators (IEC 60168:2001, MOD) GB/T 18851.1-2012 Nondestructive testing Penetrant testing Part 1: General GB/T 19519-2014 Overhead line insulators for suspension and tension composite insulation for AC systems with nominal voltages above 1000V Sub-definitions, test methods and acceptance criteria (IEC 61109:2008, MOD) GB/T 21429-2008 Definition, test methods, acceptance criteria and design of hollow composite insulators for outdoor and indoor electrical equipment Recommended (IEC 61462:1998, MOD) Note. There is no technical difference between the referenced content of GB/T 21429-2008 and the referenced content of IEC 61462:2007.

GB/T 22079 General definitions, test methods and acceptance criteria for high voltage polymer insulators for indoor and outdoor use (IEC 62217.

2012,MOD)

GB/T 25096-2010 Definition, test methods and connection of composite insulators for power station posts for substations with AC voltage higher than 1000V Acceptance criteria (IEC 62231:2006, MOD)

3 Terms and definitions

The following terms and definitions apply to this document.

Composite hollow core station post insulator composite ho low core station post insulator an insulator consists of at least three insulating parts, namely an insulating tube, an umbrella sleeve and an internal filler.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 44179-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 44179-2024

$410.00