GB/T 19519-2014Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000V - Definitions, test methods and acceptance criteria (English PDF)
架空线路绝缘子 标称电压高于1000V交流系统用悬垂和耐张复合绝缘子 定义、试验方法及接收准则
This is a limited preview
Buy now to download the full PDF (54 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19519-2014 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
June 24, 2014
Implementation date
January 22, 2015
Scope
GB/T 19519-2014 is the English-translated version of 架空线路绝缘子 标称电压高于1000V交流系统用悬垂和耐张复合绝缘子 定义、试验方法及接收准则.
GB/T 19519-2014 — This standard specifies the definitions, test methods and acceptance criteria for ac overhead lines Composite Insulators (hereinafter referred to as insulator) of.
This standard applies to AC lines, substations and drape Tension composite insulators, but these insulators in some cases may be subject to Compression or bending load, for example, as when white spacer insulators.
Insulator made of an insulating core rod, umbrella cover and end fittings constituted. Bear negative Dutch mandrel made of resin impregnated fiberglass umbrella cover from a polymer material, the end fitting permanently mounted on the insulating mandrel.
Note. China's electric power system is recommended as a high-temperature vulcanized silicone rubber umbrella cover material. This standard applies to the mandrel by a mixing section with an insulating material (such as ceramic, resin) made of composite insulators, see Chapter 7.
Insulator installation site ambient temperature is generally between -40 degrees C ~ 40 degrees C. This standard does not apply to line post insulators. This standard does not include a particular operating conditions to select the insulator requirements.
Found what you need?
Document preview — GB/T 19519-2014
National Standard of the People's Republic of China
- ICS
- 29.080.10
- Classification
- K 48
- Replacing
- GB/T 19519-2004
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and definitions, abbreviations2
- 3.1 Terms and definitions2
- 3.2 Acronyms3
- 4 Flag4
- Environmental conditions 54
- 6 Transport, storage and installation4
- Mixed insulator 47
- 8 Tolerance4
- 9 Test Category4
- 9.1 Test Design4
- 9.2 Type test6
- 9.3 Sampling Test6
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GB/T 19519-2004.
This standard compared with GB/T 19519-2004, the main technical changes are as follows.
--- According to IEC 61109.2008 statements, the standard name was changed to "Insulators for overhead lines with a nominal voltage 1000V
AC systems Suspension and tension composite insulators definitions, test methods and acceptance criteria ";
--- To reflect umbrella cover material composite insulators of power lines used in almost all the current situation of high temperature vulcanized silicone rubber, in the first
Zhang added, "Note. China's electric power system is recommended as a high-temperature vulcanized silicone rubber umbrella cover material";
--- By GB/T 2900.8-2009 and GB/T 22079-2008 published in Chapter 3 of the standard terms and their definitions are listed modifications
as follows.
- Remove the "mandrel diameter" "tracking" "dendritic channel", "erosion", "chalking (ash)" "crack" "crack" "hydrolysis phenomenon", etc.
8 terms and definitions;
- Added "hydrophobic" "hydrophobic Migration", "weakening of hydrophobic" polymer insulator "," insulator body, "" undermining load "
And Recovery "," hydrophobic migration time "" Insulator Core damage under mechanical load limit "and other eight terms and their definitions;
- Modify the "composite insulators" "composite insulators mandrel" "Interface", "end fitting" "Connection Area", "connection" and 6 patients
Language or definitions;
- The "composite insulators umbrella cover umbrella skirt and" split "umbrella cover" and "insulator umbrella" terms and definitions, respectively.
--- Added "4 flag" "5 Ambient conditions" "6 Transport, storage and installation" "Mixed insulator 7" "8 tolerance" in Chapter 5;
--- According to our measurement practices, provision creepage distance measurement in Chapter 8 does not allow extrapolation on the basis of a short section of the measurement; at the same time
Add "NOTE. For system voltage 330kV and above voltage level-element insulator creepage distances specified in this standard
The maximum tolerance difficult to achieve. In this case, by agreement between the creepage distance tolerances can be not less than its nominal size
+/- 1% ";
--- Chapter 9 presents the conceptual design that tested insulators, refinement clear need to re-test after the implementation of design changes, and Senate
According to GB/T 1001.1-2003 put forward the concept of "setting test";
--- Possible, "10 is designed to test" as described in references GB/T 22079-2008;
--- "9.2 interface and end fitting connection test", the Dry frequency voltage test room after the test by the umbrella sheath temperature rise should not exceed
20K revised to 10K;
--- "10 Design Experiment", increasing the umbrella cover material "10.3.1 hardness test" "10.3.2 1000h UV test" "10.3.6
Hydrophobic test ", and mandrel" 10.4.2 Stress Corrosion Test "and test procedures and acceptance criteria;
--- "10.2.2.3 prestressed heat engine", the total time allowed due to equipment maintenance interrupt capped by 4h modified to 2h, and any time
After the interruption, the test should be the starting point from which interrupt the cycle restarts;
--- According to our survey practice, modify the "10.3.5 umbrella cover material electrical resistance to tracking and erosion test" in the provisions relating to sample preparation, Ming
Indeed put on test samples directly from the insulator umbrella;
--- In the "10.4.1 dye penetration test and water diffusion test" shall be used as specified in the test specimen umbrella sets, according to permeate dye
GB/T 22079-2008 modify methine dyes, water provision during the current diffusion test from "should not exceed 1mA (rms)"
Was changed to "shall not exceed 100µA (rms)";
--- According to GB/T 22079-2008, flammability test method referenced by the GB/T 11020-2005 Unified modify references
GB/T 5169.16-2008;
--- "11 type test" in the "mechanical load - time trial" to "limit damage verification test";
--- Given the focus on insulator sheath thickness and deviation, "12.2 dimension check (E1 E2)" test sample clearly jacket
Thickness requirements and methods of inspection;
--- Sampling test "Front 12.6 steep wave impulse withstand voltage test" sample modified to E2 in one, and the specified test by the water
After dipping prestressed. At the same time, to reduce the workload of the test, a predetermined "over the insulating distance of 2.5m and length of insulation
Can the impulse voltage test before the child, steep waves in the insulator, the lower part depicting the short distance of about 300mm ~ 500mm of insulation
Test section, and the end fitting on one of the lower electrode test ", respectively, as;
--- To distinguish process marks, logos and cosmetic defects, "13.2 visual inspection," added "insulator surface and the presence of traces of process
Flag does not belong to manufacturing defects, but the area should be included in the total area of surface defects. The total area of the insulator surface defects must not exceed
0.2% of the total surface area of the sub edge. "The statement;
--- According to IEC 61109.2008 revised Appendix A, to correct the mechanical insulator failure mechanism understanding bias. To this end, the set
Meter test mechanical load test "insulator strength - time curve slope inspection" to "96h check load tolerance", and
Of the actual product, the IEC 61109.2008 Figure A.2 split into two figures, only example shows the mechanical properties
And the relationship between the running load, and the relationship between damage limit and its status, without explanation correspondence relationship between the two;
--- Because IEC 62217.2012 in multi-stress test is not used as a standard test, remove the GB/T 19519-2004 Annex C (funded
Material appendix);
--- And for the IEC 61109.2008 unified deleted GB/T 19519-2004 Annex D (informative) Appendix E (Data
Appendix) Appendix F (informative), an increase of Annex B (informative). Suspension and tension composite insulators nonstandard machine
Mechanical stresses and mechanical dynamic load.
This standard uses redrafted law revision adopted IEC 61109.2008 "Insulators for overhead lines with a nominal voltage 1000V AC
Suspension systems and tension composite insulators definitions, test methods and acceptance criteria. "
This standard and IEC 61109.2008 as compared to some technical differences in terms of these differences has been involved through its outer margin
AC power frequency arc tests of details.
Suspension and tension composite insulators are usually not subjected to twisting or other non-tensile load, Appendix B gives a nonstandard load guidelines.
Insulators for overhead lines with a nominal voltage 1000V
AC systems Suspension and tension composite insulators
Definitions, test methods and acceptance criteria
1 Scope
This standard specifies the definitions, test methods and acceptance criteria for ac overhead lines Composite Insulators (hereinafter referred to as insulator) of.
This standard applies to AC lines, substations and drape Tension composite insulators, but these insulators in some cases may be subject to
Compression or bending load, for example, as when white spacer insulators. Insulator made of an insulating core rod, umbrella cover and end fittings constituted. Bear negative
Dutch mandrel made of resin impregnated fiberglass umbrella cover from a polymer material, the end fitting permanently mounted on the insulating mandrel.
Note. China's electric power system is recommended as a high-temperature vulcanized silicone rubber umbrella cover material.
This standard applies to the mandrel by a mixing section with an insulating material (such as ceramic, resin) made of composite insulators, see Chapter 7.
Insulator installation site ambient temperature is generally between -40 degrees C ~ 40 degrees C.
This standard does not apply to line post insulators.
This standard does not include a particular operating conditions to select the insulator requirements.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 1001.1-2003 nominal voltage above 1000V Insulators for overhead lines - Part 1. Ceramic or glass AC system
Insulator element definitions, test methods and acceptance criteria (IEC 60383-1.1993, MOD)
GB/T 1001.2-2010 nominal voltage above 1000V Insulators for overhead lines - Part 2. Communication systems insulator strings
Insulator strings and group definitions, test methods and acceptance criteria (IEC 60383-2.1993, MOD)
GB/T 2900.8-2009 Electrotechnical terminology insulator (IEC 60050-471.2007, IDT)
GB/T 5169.16-2008 Fire hazard testing for electric and electronic products - Part 16. Test flames - 50W horizontal and vertical fire
Flame test methods (IEC 60695-11-10.2003, IDT)
GB/T 6553-2003 assessment used under severe ambient conditions of electrical insulating materials resistance to tracking and erosion test methods
(IEC 60587. 1984, IDT)
GB/T 16422.1-2006 Plastics - Methods of exposure to laboratory light sources - Part 1. General (ISO 4892-1.1999,
IDT)
GB/T 16422.2-2014 Plastics - Methods of exposure to laboratory light sources - Part 2. Xenon arc lamps (ISO 4892-2.2006,
IDT)
GB/T 18851.1-2012 destructive testing - Penetrant testing - Part 1. General (ISO 3452-1.2008, IDT)
GB/T 18851.4-2005 destructive testing - Penetrant testing - Part 4. Equipment (ISO 3452-4.1998, IDT)
GB/T 21421.1-2008 higher than 1000V nominal voltage overhead lines Composite string insulator units - Part 1. Standard Strong
Grade and end fittings (IEC 61466-1.1997, IDT)
GB/T 22079-2008 nominal voltage greater than 1000V indoor and outdoor use polymer insulators General definitions, test side
Method and acceptance criteria (IEC 62217.2005, MOD)
GB/T 24622-2009 insulator surface wettability measurement guidelines (IEC /T S62073.2003, IDT)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 54 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1001.1-2003Insulators for overhead lines with a nominal voltage above 1 000V - Part 1: Ceramic or glass insulator units for a. c. systems - Definitions, test methods and acceptance criteria
- GB/T 1001.2-2010Insulators for overhead lines with a nominal voltage above 1000V -- Part 2: Insulator strings and insulator sets for a.c. systems -- Definitions, test methods and acceptance criteria
- GB/T 2900.8-2009Electrotechnical terminology -- Insulators
- GB/T 5169.16-2008Fire hazard testing for electric and electronic products -- Part 16: Test flames--50 W horizontal and vertical flame test methods
- GB/T 6553-2003Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
- GB/T 16422.1-2006Plastics -- Methods of exposure to laboratory light sources -- Part 1: General guidance
IEC 60383 · IEC 60050 · IEC 60695 · IEC 60587 · ISO 4892 · ISO 3452 · IEC 61466 · IEC 62217.2005
Cited by
- GB/T 33097-2025Elastic insulating suspension components
- GB/T 44179-2024Composite hollow core station post insulators with a. c. voltage greater than 1 000 V and d. c. voltage greater than 1 500 V - Definitions, test methods and acceptance criteria
- GB/T 15166.3-2023High-voltage alternating-current fuses - Part 3: Expulsion fuses
- GB/T 21421.1-2021Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 1: Standard strength classes and end fittings
- DL/T 640-2019High voltage AC drop fuse
- DL/T 1000.3-2015Application guide of insulators for overhand lines with a nominal voltage over 1000V - Part 3: Composite insulator for a.c. system
How to Download GB/T 19519-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1001.2-2010 — Insulators for overhead lines with a nominal voltage above 1000V -- Part 2: Insulator strings and insulator sets for a.c. systems -- Definitions, test methods and acceptance criteria
GB/T 18851.4-2005 — Non-destructive testing -- Penetrant testing -- Part 4: Equipment
GB/T 2900.8-2009 — Electrotechnical terminology -- Insulators
Secure payment via Stripe
Payments accepted
GB/T 19519-2014
$475.00