Valid

GB/T 6102.2-2012Test method for moisture regain in raw cotton - Electrical resistance meter (English PDF)

原棉回潮率试验方法 电阻法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 6102.2-2012 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 14, 2012

Implementation date

September 1, 2013

Scope

GB/T 6102.2-2012 is the English-translated version of 原棉回潮率试验方法 电阻法.

GB/T 6102.2-2012 is the Chinese standard "Test method for moisture regain in raw cotton - Electrical resistance meter". Its scope clause reads: This Standard specifies the test method for moisture regain in raw cotton through the principle of the electrical resistance method.

This Standard is applicable to raw cotton with moisture regain of 3% ~ 13%. Its clauses include terms and definitions; principle; technical requirements of instrument; environmental requirements; detection modes and requirements; detection steps; detection results; detection report.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on NOVEMBER 14, 2012 and took effect on SEPTEMBER 1, 2013.

Found what you need?

Document preview — GB/T 6102.2-2012

National Standard of the People's Republic of China

ICS
59.060.10
Classification
B 32
Replacing
GB/T 6102.2-2009

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative References5
  • 3 Terms and Definitions5
  • 4 Principle6
  • 5 Technical Requirements of Instrument6
  • 6 Environmental Requirements6
  • 7 Detection Modes and Requirements7
  • 8 Detection Steps7
  • 9 Detection Results7
  • 10 Detection Report7
  • Appendix A (normative) Technical Requirements and Steps of Detection with an Electrical Meter8
  • Appendix B (normative) Technical Requirements and Steps of Detection with an Online Device10
  • Appendix C (normative) Technical Requirements and Steps of Detection with an Insertion Device11

Foreword

This Standard was drafted in accordance with the rules provided in GB/T 1.1-2009.

This Standard serves as a replacement of GB/T 6102.2-2009 Test Method for Moisture Regain in Raw Cotton - Electrical Moisture Meter.

In comparison with GB/T 6102.2-2009, the main content of revision is as follows:

---The specific instrument measurement is classified as the principle measurement; "the test method for moisture regain in raw cotton through electrical meter" is modified into "the test method for moisture regain in raw cotton through the principle of electrical resistance method".

---"GB 6975 Cotton Baling" is added to Normative References.

---"GB 1103" is modified into "GB 1103.1" in Normative References; "GB 1103.2" is added to Normative References.

---"GB/T 8170 Rules of Rounding off for Numerical Values & Expression and Judgement of Limiting Values" is modified in Normative References.

---The Scope of this Standard is modified into "raw cotton with moisture regain of 3% ~ 13%".

---The definition of the measurement of moisture regain in raw cotton through the principle of the electrical resistance method is clarified. The "negative correlation" is clarified as "non-linear negative correlation"; the test condition "mass of specimen" is put into the "detection modes and requirements"; the step "perform temperature compensation" is added.

---The measurement voltage is modified from "DC (90 ± 1) V" into "measurement voltage: less than 100 V (DC). The maximum allowable error: less than 50 V (DC), less than ± 4% of the rated value; 50 V ~ 100 V (DC), less than ± 1.5% of the rated value".

---The "test sample" is modified into "detection modes and requirements". In addition, "electrical meter detection: the sampling size and method shall comply with the stipulations of GB 1103.1, GB 1103.2 and GB 19635. Online device detection: applicable to Type I saw ginned cotton specified in GB 6975; in the process of baling, the bale is not opened for fixed-point inspection; the measurement depth shall be 1 cm ~ 5 cm. Insertion device detection: applicable to Type I saw ginned cotton; after bailing, the bale is not opened for fixed-point inspection; the test point shall be 10 cm ~ 15 cm inward from the outer layer of the cotton bale" is clarified.

---The "test results" is modified into "detection results". In addition, "electrical meter detection: in accordance with the sampling size specified in GB 1103.1, GB 1103.2 and Test Method for Moisture Regain in Raw Cotton - Electrical Resistance Meter

1 Scope

This Standard specifies the test method for moisture regain in raw cotton through the principle of the electrical resistance method.

This Standard is applicable to raw cotton with moisture regain of 3% ~ 13%.

2 Normative References

The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB 1103.1 Cotton - Part 1: Saw Ginned Upland Cotton

GB 1103.2 Cotton - Part 2: Roller Ginned Upland Cotton

GB 6975 Cotton Baling

GB/T 8170 Rules of Rounding of for Numerical Values & Expression and Judgement of Limiting Values

GB 19635 Cotton - Sea Island Cotton

3 Terms and Definitions

The following terms and definitions are applicable to this document.

3.1 Moisture Weight

Moisture weight refers to the weight of raw cotton when it contains moisture.

3.2 Dry Weight

Dry weight refers to the weight of raw cotton after removing moisture through a certain method.

3.3 Moisture Regain

Moisture regain refers to the difference between the moisture weight and the dry weight of the […]

7 Detection Modes and Requirements

7.1 Electrical meter detection: the sampling size and method shall comply with the stipulations of GB 1103.1, GB 1103.2 and GB 19635.

7.2 Online device detection: applicable to Type I saw ginned cotton specified in GB 6975; in the process of baling, the bale is not opened for fixed-point inspection; the measurement depth shall be 1 cm ~ 5 cm.

7.3 Insertion device detection: applicable to Type I saw ginned cotton specified in GB 6975; after bailing, the bale is not opened for fixed-point inspection; the test point shall be 10 cm ~ 15 cm inward from the outer layer of the cotton bale.

8 Detection Steps

See the detection steps in Appendix A, Appendix B and Appendix C.

9 Detection Results

9.1 Electrical meter detection: in accordance with the sampling size specified in GB 1103.1,

GB 1103.2 and GB 19635, perform the detection piece by piece, record the detection results, then, calculate the arithmetic mean of moisture regain of batch samples and take it as the detection result.

9.2 Online device detection: issue the detection results of moisture regain bale by bale.

9.3 Insertion device detection: for the bale-by-bale detection, issue the detection results of moisture regain bale by bale; for the detection by batches, in accordance with the sampling size specified in GB 1103.1, GB 1103.2 and GB 19635, perform the detection bale by bale, record the detection results, then, calculate the arithmetic mean of moisture regain of batch samples and take it as the detection result.

9.4 The detection results shall be rounded off to one decimal place in accordance with GB/T 8170.

10 Detection Report

In accordance with the requirements of different detection instruments, issue the detection report on moisture regain. The content of the report includes: moisture regain or average moisture regain, quantity of test specimens, sample source, sample No., cotton type, rolling mode, inspection basis, instrument type, detection date, and temperature and humidity of detection environment, etc.

Appendix A (normative) Technical Requirements and Steps of Detection with an Electrical Meter

A.1 Technical Requirements

A.1.1 Plate area: (235 x 100) mm²
A.1.2 Plate pressure: (735 ± 30) N

A.1.3 Mass of specimen: (50 ± 5) g.

A.1.4 Environmental adaptability

temperature of operating environment: - 30 °C ~ + 50 °C. when the moisture regain of the specimen is below 5.0%, the relative humidity of the environment shall be <= 30%; when the moisture regain of the specimen is 5.0% ~ 7.0%, the relative humidity of the environment shall be <= 65%; when the moisture regain of the specimen is 7.0% ~ 13.0%, the relative humidity of the environment shall be <= 85%.

A.2 Detection Steps

A.2.1 Instrument calibration: in accordance with the metrological verification procedures, calibrate the instrument.

A.2.2 Sampling: the sampling size and method shall comply with the stipulations of GB 1103.1,

GB 1103.2 and GB 19635, or the methods negotiated by the parties concerned.

A.2.3 Sample processing: during the on-site inspection, the test can be performed while taking the sample. For the samples tested in the laboratory, the obtained samples, together with the sample container, shall be placed in the test environment for temperature balance, so that the temperature difference with the environment is within ± 2 °C. From the time of obtaining the sample, the test of the moisture regain shall be completed within 24 h.

A.2.4 Instrument adjustment: in accordance with the instruction manual of the instrument, check the various functions of the instrument, so that it can be in a normal state.

A.2.5 Test: in accordance with the ginning mode and the variety of cotton (fine-staple cotton or long-staple cotton), select a corresponding test gear. From each test sample, take out (50 ± 5) g […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 6102.2

EditionTitleRevisionStatus
GB/T 6102.2-2012Test method for moisture regain in raw cotton - Electrical resistance metercurrent editionCurrent
GB/T 6102.2-2009Test method for moisture regain in raw cotton - Electrical resistance meterprevious editionSuperseded

This page sells the current edition, GB/T 6102.2-2012. Earlier editions are listed for reference only.

How to Download GB/T 6102.2-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 6102.2-2012