GB/T 2952.1-2008Protective coverings for electric cables - Part 1: General (English PDF)
电缆外护层 第1部分:总则
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 2952.1-2008 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2008
Implementation date
November 1, 2009
Scope
GB/T 2952.1-2008 is the English-translated version of 电缆外护层 第1部分:总则.
GB/T 2952.1-2008 is the Chinese standard "Protective coverings for electric cables - Part 1: General". Its scope clause reads: This part of GB/T 2952 specifies the type, model designation, structure, dimension, technical requirements and test method of the protective coverings for electric cables (hereinafter referred to as "protective coverings").
This part is applicable to fixed formation power cables (including oil-filled cables), and communication, signal, control cables, etc. as well as optical cables.
The protective coverings which are not specified in this part and have other special requirement shall be specified separately in the corresponding product standards. Its clauses include terms and definitions; type and model designation.
Found what you need?
Document preview — GB/T 2952.1-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
- Replacing
- GB/T 2952.1-1989
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword i
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Type and model designation
- 5 Structural requirements
- 6 Material requirements
- 7 Performance requirements
- 8 Test method
- Annex A (Informative) Technical requirements for corrugated cable paper
- Annex B (Informative) Main technical requirements for non-woven fabrics for cables
- Annex C (Informative) Main technical requirements for non-woven jute for cables
- Bibliography
1 Scope
This part of GB/T 2952 specifies the type, model designation, structure, dimension, technical requirements and test method of the protective coverings for electric cables (hereinafter referred to as "protective coverings").
This part is applicable to fixed formation power cables (including oil-filled cables), and communication, signal, control cables, etc. as well as optical cables.
The protective coverings which are not specified in this part and have other special requirement shall be specified separately in the corresponding product standards.
2 Normative references
The following documents contain provisions which, through reference in this part of GB/T 2952, constitute provisions of this part. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB/T 2059-2000 Strips of copper and copper alloys
GB/T 2696-1987 Skeined colour jute threads — Technical requirements and grading stipulation
GB/T 2900.10 Electrotechnical vocabulary — Electric cables (GB/T 2900.10-2001, idt IEC 60050(461):1984)
GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables — Part 11: Methods for general application — Measurement of thickness and overall dimensions — Tests for determining the mechanical properties (IEC 60811-1-1:2001, IDT)
GB/T 3048.10-2007 Test methods for electrical properties of electric cables and wires — Part 10: Spark test of extruded protective sheaths
GB/T 3082-1984 Galvanized low carbon steel wire for armouring cables;
GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) — Part 1: Cables for rated voltage of 1kV (Um=1.2kV) and 3kV (Um=3.6kV) (IEC 60502-1:2004, Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) — Part 1: Cables for rated voltage of 1kV(Um=1.2kV) and 3kV(Um=3.6kV), MOD)
JB/T 10696.3-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires — Part 3: Bending test
JB/T 10696.4-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires — Part 4: Test for copper naphthenate content of protective coverings
JB/T 10696.5-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires — Part 5: Corrosion spread test
JB/T 10696.6-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires — Part 6: Test for abrasion of oversheaths
SH/T 0001-1990 Cable asphalt
YB/T 024-2008 Steel strips for cable armouring
3 Terms and definitions
For the purposes of this part, the terms and definitions given in GB/T 2900.10 and the following apply.
3.1 protective coverings
protective coatings that cover the metallic, non-metallic or combined sheath of a cable to protect the cable from mechanical damage and corrosion or those with such protection and other special functions
4 Type and model designation
4.1 Types of protective coverings
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 13849-2025Communication cables with polyolefin insulation and moisture barrier polyolefin sheath up to 1MHz
- JB/T 13108-2017Silicone rubber insulated control cables of rated voltages up to and including 450/750 V
- JB/T 5332.1-2011Electric submersible pump cables of rated voltages up to and including 3.6/6 kV - Part 1: General requirements
- JB/T 5332.2-2011Electric submersible pump cables of rated voltages up to and including 3.6/6 kV - Part 2: Motor lead cables
- JB/T 5332.3-2011Electric submersible pump cables of rated voltages up to and including 3.6/6 kV - Part 3: Flat power cables
- JB/T 5332.4-2011Electric submersible pump cables of rated voltages up to and including 3.6/6 kV - Part 4: Round power cables
Similar standards
Editions of GB/T 2952.1
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 2952.1-2008 | Protective coverings for electric cables - Part 1: General | current edition | Current |
| GB/T 2952.1-1989 | Protective coverings for electric cables - Part 1: General | previous edition | Superseded |
This page sells the current edition, GB/T 2952.1-2008. Earlier editions are listed for reference only.
How to Download GB/T 2952.1-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2952.2-2008 — Protective coverings for electric cables - Part 2: Protective coverings for cables with metallic sheath
GB/T 2952.3-2008 — Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheath
GB/T 7251.4-2026 — Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
Secure payment via Stripe
Payments accepted
GB/T 2952.1-2008
$195.00