Scope

GB/T 2952.3-2008 is the English-translated version of 电缆外护层 第3部分:非金属套电缆通用外护层.

GB/T 2952.3-2008 is the Chinese standard "Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheath". Its scope clause reads: This section GB/T 2952 specifies the type of non-metallic sheath cable General protective layer, name, structure, size and technical requirements.

This section applies to the outer sheath having a non-metallic sleeve is fixed with laying of electricity, communications, signal and control cables, non-metallic The sleeve may be extruded, for example plastic sleeve may be around the package.

This section does not apply to cable outer sheath have other special requirements. Its clauses include model, name.

Found what you need?

Document preview — GB/T 2952.3-2008

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13
Replacing
GB/T 2952.3-1989

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 model, name
  • 4 structures and materials
  • Annex C (normative) plastic outer sheath nominal thickness

1 Scope

This section GB/T 2952 specifies the type of non-metallic sheath cable General protective layer, name, structure, size and technical requirements.

This section applies to the outer sheath having a non-metallic sleeve is fixed with laying of electricity, communications, signal and control cables, non-metallic

The sleeve may be extruded, for example plastic sleeve may be around the package.

This section does not apply to cable outer sheath have other special requirements.

2 Normative references

The following documents contain provisions which, through reference to GB/T 2952 to the present, constitute provisions of this section. For dated reference documents

Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section

Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 2952.1-2008 cable outer sheath - Part 1. General

3 model, name

Model non-metallic sheathed cable General protective layer, the name should be consistent with the provisions of GB T 2952.1-2008 and/Table 1, Table 1 is recommended for

It listed the main laying sites.

Table 1 sets of non-metallic cable General protective layer model, the name and principal place laying

Model Name

Mainly suitable place for laying

Laying special environment

Indoor tunnel cable pipeline

Buried general soil

More gravel

Shaft underwater flammable serious corrosion pull

12 interlocked steel tape armored PVC jacket * * * * * * *

22 steel tape armored PVC jacket * * * * * * *

Steel tape armored PE (PO)

Coat * * * * *

32 fine round steel wire armored PVC jacket * * * * * * *

Fine round steel wire armored PE (polyolefin

Hydrocarbon) coat * * * * * *

34 fine round steel wire armored elastomer jacket * * * * * *

41 Cuyuan steel wire armored fiber is * - *

52 Corrugated steel tape armored PVC jacket * * * * * * *

Corrugated steel tape armored PE (or polyolefin

Hydrocarbon) coat * * * * * […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 2952.3

EditionTitleRevisionStatus
GB/T 2952.3-2008Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheathcurrent editionCurrent
GB/T 2952.3-1989Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheathprevious editionSuperseded

This page sells the current edition, GB/T 2952.3-2008. Earlier editions are listed for reference only.

How to Download GB/T 2952.3-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 2952.3-2008

$195.00