GB/T 2952.3-2008Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheath (English PDF)
电缆外护层 第3部分:非金属套电缆通用外护层
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 2952.3-2008 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2008
Implementation date
November 1, 2009
Scope
GB/T 2952.3-2008 is the English-translated version of 电缆外护层 第3部分:非金属套电缆通用外护层.
GB/T 2952.3-2008 is the Chinese standard "Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheath". Its scope clause reads: This section GB/T 2952 specifies the type of non-metallic sheath cable General protective layer, name, structure, size and technical requirements.
This section applies to the outer sheath having a non-metallic sleeve is fixed with laying of electricity, communications, signal and control cables, non-metallic The sleeve may be extruded, for example plastic sleeve may be around the package.
This section does not apply to cable outer sheath have other special requirements. Its clauses include model, name.
Found what you need?
Document preview — GB/T 2952.3-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
- Replacing
- GB/T 2952.3-1989
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 model, name
- 4 structures and materials
- Annex C (normative) plastic outer sheath nominal thickness
1 Scope
This section GB/T 2952 specifies the type of non-metallic sheath cable General protective layer, name, structure, size and technical requirements.
This section applies to the outer sheath having a non-metallic sleeve is fixed with laying of electricity, communications, signal and control cables, non-metallic
The sleeve may be extruded, for example plastic sleeve may be around the package.
This section does not apply to cable outer sheath have other special requirements.
2 Normative references
The following documents contain provisions which, through reference to GB/T 2952 to the present, constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 2952.1-2008 cable outer sheath - Part 1. General
3 model, name
Model non-metallic sheathed cable General protective layer, the name should be consistent with the provisions of GB T 2952.1-2008 and/Table 1, Table 1 is recommended for
It listed the main laying sites.
Table 1 sets of non-metallic cable General protective layer model, the name and principal place laying
Model Name
Mainly suitable place for laying
Laying special environment
Indoor tunnel cable pipeline
Buried general soil
More gravel
Shaft underwater flammable serious corrosion pull
12 interlocked steel tape armored PVC jacket * * * * * * *
22 steel tape armored PVC jacket * * * * * * *
Steel tape armored PE (PO)
Coat * * * * *
32 fine round steel wire armored PVC jacket * * * * * * *
Fine round steel wire armored PE (polyolefin
Hydrocarbon) coat * * * * * *
34 fine round steel wire armored elastomer jacket * * * * * *
41 Cuyuan steel wire armored fiber is * - *
52 Corrugated steel tape armored PVC jacket * * * * * * *
Corrugated steel tape armored PE (or polyolefin
Hydrocarbon) coat * * * * * […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 2952.3
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 2952.3-2008 | Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheath | current edition | Current |
| GB/T 2952.3-1989 | Protective coverings for electric cables - Part 3: General protective coverings for cables with non-metallic sheath | previous edition | Superseded |
This page sells the current edition, GB/T 2952.3-2008. Earlier editions are listed for reference only.
How to Download GB/T 2952.3-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2952.1-2008 — Protective coverings for electric cables - Part 1: General
GB/T 2952.2-2008 — Protective coverings for electric cables - Part 2: Protective coverings for cables with metallic sheath
GB/T 7251.4-2026 — Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
Secure payment via Stripe
Payments accepted
GB/T 2952.3-2008
$195.00