GB/T 12976.2-2008Paper-insulated power cables and their accessories with rated voltages up to and including 35kV -- Part 2: General and construction requirements for power cables with rated voltages 35kV (English PDF)
额定电压35kV(Um=40.5kV)及以下纸绝缘电力电缆及其附件 第2部分:额定电压35kV电缆一般规定和结构要求
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for GB/T 12976.2-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 30, 2008
Implementation date
April 1, 2009
Scope
GB/T 12976.2-2008 is the English-translated version of 额定电压35kV(Um=40.5kV)及以下纸绝缘电力电缆及其附件 第2部分:额定电压35kV电缆一般规定和结构要求.
GB/T 12976.2-2008 — 1.1 GB/T 12976 provisions of this part of the rated voltage 21/35kV, 26/35kV (Um = 40.5kV) copper or aluminum impregnated paper must General provisions edge lead sheathed power cable (excluding gas - pressure and oil-filled cables) and structural requirements.
GB/T 12976 in this section applies to the rated voltage 21/35kV, 26/35kV (Um = 40.5kV) copper or aluminum impregnated paper must Edge lead sheathed power cables (excluding gas - pressure and oil-filled cables).
Submarine cables and special purpose cable, not included in this section. NOTE. Test methods and the corresponding requirements set out in the first part. 1.2 The maximum allowable operating temperature Table 1 to a temperature suitable for viscous oil impregnated and not trickle impregnation.
When such other maximum permissible continuous operating temperature, test temperature should be adjusted accordingly.
Table 1 insulated conductors of different voltage and maximum temperature Cable's rated voltage (U0/U) /kV Highest voltage for equipment Um /kV Maximum conductor temperature to allow normal operation no trickle of oil-impregnated cable /Viscous oil impregnated cable /21/35 40.5 6560 26/35 40.5 6560 Note 1.
The use of viscous oil impregnated in this table applies only to a temperature substantially horizontal cable buried in the soil. Note 2. For use not trickle impregnation, suitable for vertical cable laying occasions.
Note 3. If the cable buried in the soil to allow continuous operation at maximum conductor temperature (100% load factor), the soil surrounding the cable may vary depending on the starting resistance Since the time the soil dries leaving the thermal resistance becomes large.
Therefore, the conductor temperature may significantly exceed the maximum allowable value, if the expected presence of such operating conditions, should Take appropriate measures.
Found what you need?
Document preview — GB/T 12976.2-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
- Replacing
- GB/T 12976.1-1991; GB/T 1296.2-1991; GB/T 12976.3-1991
Issued by: Standardization Administration of China
Contents
- What this standard covers1
- Document data2
- Standards quoted by this document3
What this standard covers
This standard specifies the rated voltage 21/35kV, 26/35kV copper or aluminum impregnated paper insulated lead sheathed power cables General and construction requirements. GB/T 12976 This part applies to the rated voltage 21/35kV, 26/35kV copper or aluminum impregnated paper insulated lead sheathed power cable. Submarine cables and special purpose cable, not included in this portion.
Document data
International classification (ICS): 29.060.20.
Chinese classification (CCS): K13.
Estimated length of the Chinese original: 18,111 words.
Adopted international standard: IEC 60055-2-1981, NEQ.
Supersedes the earlier edition GB/T 12976.1-1991; GB/T 1296.2-1991; GB/T 12976.3-1991.
Standards quoted by this document
GB/T 2900.10-2001; GB/T 2952.1-1989; GB/T 2952.2-1989; GB/T 3956-1997; GB/T 6995.3-2008; GB/T 12706.2-2002; GB/T 12976.3-2008; JB/T 8137.1-1999; JB/T 8137.2-1999; JB/T 8137.3-1999; JB/T 8137.4-1999; JB/T 8996-1999
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2900.10-2001Electrotechnical terminology -- Electric cables
- GB/T 2952.1-1989Protective coverings for electric cables - Part 1: General
- GB/T 2952.2-1989Protective coverings for electric cables - Part 2: Protective coverings for cables with metallic sheath
- GB/T 3956-1997Conductors of insulated cables
- GB/T 6995.3-2008Markings for electric wires and cables - Part 3: Identifications of cables and wires
GB/T 12976 · IEC 60050 · IEC 60228
How to Download GB/T 12976.2-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12976.1-2008 — Paper-insulated power cables and their accessories with rated voltages up to and including 35kV -- Part 1: General and construction requirements for power cables with rated voltages up to and including 30kV
GB/T 12976.3-2008 — Paper-insulated power cables and their accessories with rated voltages up to and including 35kV -- Part 3: Test on cables and their accessories
GB/T 6995.3-2008 — Markings for electric wires and cables - Part 3: Identifications of cables and wires
Secure payment via Stripe
Payments accepted
GB/T 12976.2-2008
$404.00