GB/T 25499-2010 is the English-translated version of 城市污水再生利用 绿地灌溉水质.

GB/T 25499-2010 is the Chinese standard "The reuse of urban recycling water - Water quality standard for green space irrigation". Its scope clause reads: This Standard specifies the water quality indicators and limits, sampling and monitoring for green space irrigation of reuse of urban recycling water.

This Standard is applicable to the recycled water used for green space irrigation that takes the urban recycling water as water source. Its clauses include terms and definitions; water quality requirements; other provisions; sampling and monitoring.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on DECEMBER 1, 2010 and took effect on SEPTEMBER 1, 2011.

Found what you need?

Document preview — GB/T 25499-2010

National Standard of the People's Republic of China

ICS
13.060
Classification
P 40

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions7
  • 4 Water quality requirements7
  • 5 Other provisions9
  • 6 Sampling and monitoring9
  • Bibliography13

Foreword

This Standard is one of series of standards of "the reuse of urban recycling water".

1 Scope

This Standard specifies the water quality indicators and limits, sampling and monitoring for green space irrigation of reuse of urban recycling water.

This Standard is applicable to the recycled water used for green space irrigation that takes the urban recycling water as water source.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 5750 (all parts), Standard examination methods for drinking water

GB/T 6920, Water quality - Determination of pH value - Glass electrode method

GB/T 7467, Water quality - Determination of chromium(6) - 1.5 Diphenylcarbahydrazide spectrophotometric method

GB/T 7468, Water quality - Determination of total mercury - Cold atomic absorption spectrophotometry

GB/T 7470, Water quality - Determination of lead - Spectrophotometric method with dithizone

GB/T 7471, Water quality - Determination of cadmium - Spectrophotometric method with dithizone

GB/T 7472, Water quality - Determination of zinc - Spectrophotometric method with dithizone

GB/T 7473, Water quality - Determination of copper - 2,9-Dimethyl-1,10-phenanthroline spectrophotometric method

GB/T 7474, Water quality - Determination of copper - Sodium diethyldithiocarbamate spectrophotometric method

GB/T 7475, Water quality - Determination of copper, zinc, lead and cadmium - Atomic absorption spectrometry

GB/T 7476, Water quality - Determination of calcium - EDTA titrimetric method

GB/T 7479, Water quality - Determination of ammonium - Nessler's reagent colorimetric method

GB/T 7481, Water quality - Determination of ammonium - Spectrophotometric method with salicylic acid

GB/T 7483, Water quality - Determination of fluoride; Fluor reagent spectrophotometric method

GB/T 7484, Water quality - Determination of fluoride - ion selective electrode method

GB/T 7485, Water quality - Determination of total arsenic - Silver diethyldithiocarbamate spectrophotometric method

GB/T 7486, Water quality - Determination of cyanide - Part 1. Determination of total cyanide

GB/T 7487, Water quality - Determination of cyanide - Part 2. Determination of cyanide

GB/T 7488, Water quality - Determination of biochemical oxygen demand after 5 days (BOD5) - Dilution and seeding method

GB/T 7494, Water quality - Determination of anionic surfactants - Methylene blue spectrophotometric method

GB 7959, Sanitary Standard for the non-hazardous treatment of night soil

GB/T 8538, Methods for examination of drinking natural mineral water

GB/T 11890, Water quality - Determination of benzene and its analogies - Gas chromatographic method

GB/T 11896, Water quality - Determination of chloride - Silver nitrate titration method

GB/T 11898, Water quality - Determination of free chlorine and total chlorine - Spectrophotometric method using N,N-diethyl-1,4 phenylenediamine

5 Other provisions

5.1 Before the irrigation of urban recycling water to green space, the basic control projects and selective control projects of the recycling water sources shall be fully tested. Carry out the irrigation test according to local climatic conditions, green plant species and soil conditions to confirm the selective control items and irrigation system.

5.2 Ancient trees must not be irrigated with the recycling water. Special flowers and newly introduced plants shall be carefully irrigated with the recycling water.

5.3 When using the recycling water to irrigate the green space, an emergency preparation plan shall be made. When an emergency occurs, stop using the recycling water immediately.

6 Sampling and monitoring

6.1 Sampling requirements

6.1.1 The sampling point of the water quality is located near the discharge port of the recycling water treatment facility to ensure that the nearest irrigation water quality comply with the provisions of this Standard.

6.1.2 The collection and storage of water sample shall be in line with GB/T 12998 and GB/T 12999. Conduct the sampling at least once every 2h. Take 24 mixed samples, calculated in daily average. When conditions permit, the sampling in proportion of recycling water and online monitoring shall be gradually realized.

6.2 Monitoring frequency

When it uses the recycling water to irrigate the green space, the water quality monitoring frequency shall not be less than the following requirements.

Basic control items. once a day for total residual chlorine, turbidity, olfactory, pH value; once every week for fecal coliforms; once every month for other items.

22 Benzene <=2.5

NOTE Except item 1, the unit for other items shall be mg/L. a, where the concentration units for sodium, calcium, magnesium ion are expressed in mmol/L. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 5750 · GB/T 7468 · GB/T 7473 · GB/T 7474 · GB/T 7479 · GB/T 7481 · GB/T 7483 · GB/T 7486 · GB/T 7487 · GB/T 7488 · GB/T 11890 · GB/T 11896 · GB/T 11898

Similar standards

How to Download GB/T 25499-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 25499-2010

$105.00