Superseded

GB/T 5750.10-2006Standard examination methods for drinking Water -- Disinfection by-products parameters (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (65 pages)

Need quotation for your management?

Get a formal quotation for GB/T 5750.10-2006 in 30 minutes.

Issued by

Ministry of Health of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 29, 2006

Implementation date

July 1, 2007

Scope

GB/T 5750.10-2006 (Standard examination methods for drinking Water -- Disinfection by-products parameters) is available as an English-translated PDF.

GB/T 5750.10-2006 — This standard specifies the use of headspace gas chromatography for the determination of dichloromethane, 1,1-dichloroethane and 1,2-dichloroethane in drinking water and its source water.

This method applies to the determination of dichloromethane, 1,1- dichloroethane and 1,2-dichloroethane in drinking water and its source water.

The minimum detection mass concentration of this method. dichloromethane 9 µg/L, 1,1-dichloroethane 8 µg/L, 1,2-dichloroethane 13 µg/L. Under the operating conditions of this method, other halogenated hydrocarbons do not interfere.

Found what you need?

Document preview — GB/T 5750.10-2006

National Standard of the People's Republic of China

ICS
13.060
Classification
C 51

Issued by: Ministry of Health of the People's Republic of China

Contents

  • 1 Trichloromethane..6
  • 2 Tribromomethane..6
  • 3 Dichloro-bromomethane..6
  • 4 Chlorodibromomethane.6
  • 5 Dichloromethane..6
  • 6 Formaldehyde..11
  • 7 Acetaldehyde.15
  • 8 Trichloroacetaldehyde.21
  • 9 Dichloroacetic acid.26
  • 10 Trichloroacetic acid..31
  • 11 Cyanogen chloride..31
  • 12 2,4,6-trichlorophenol..33
  • 13 Chlorite..44
  • 14 Bromate.56
  • Appendix A (Normative) References..65

Foreword

GB/T 5750 "Standard Test Method for Drinking Water" is divided into the

following parts.

- General principles;

- Collection and preservation of water samples;

- Water analysis quality control;

- Organoleptic and physical parameters;

- Nonmetal parameters;

- Metal parameters;

- Aggregate organic parameters;

- Organic parameters;

- Pesticides parameters;

- Disinfection by-products parameters;

- Disinfectants parameter;

- Microbiological parameters;

- Radiological parameters.

This standard replaces chloroform in the part II of GB/T 5750-1985 "Standard

examination methods for drinking water".

As compared with GB/T 5750-1985, the main changes are as follows.

- ADJUST the structure in accordance with GB/T 1.1-2000 "Directives for

standardization - Part 1.Rules for the structure and drafting of standards"

and GB/T 20001.4-2001 "Rules for drafting standards - Part 4.Methods of

chemical analysis";

- REVISE the quantity and measurement unit in accordance with the

requirements of national standards;

- CHANGE the equivalent concentration into the molar concentration (the

redox part still retains the equivalent concentration);

- CHANGE the mass concentration indication symbol C into rho, CHANGE the

Standard examination methods for drinking water -

Disinfection by-product parameters

1 Trichloromethane

Same as the test method for carbon tetrachloride in Chapter 1 of GB/T 5750.8-

2006.

2 Tribromomethane

Same as the test method for carbon tetrachloride in Chapter 1 of GB/T 5750.8-

2006.

3 Dichloro-bromomethane

Same as the test method for carbon tetrachloride in Chapter 1 of GB/T 5750.8-

2006.

4 Chlorodibromomethane

Same as the test method for carbon tetrachloride in Chapter 1 of GB/T 5750.8-

2006.

5 Dichloromethane

5.1 Headspace gas chromatography

5.1.1 Scope

This standard specifies the use of headspace gas chromatography for the

determination of dichloromethane, 1,1-dichloroethane and 1,2-dichloroethane

in drinking water and its source water.

This method applies to the determination of dichloromethane, 1,1-

dichloroethane and 1,2-dichloroethane in drinking water and its source water.

The minimum detection mass concentration of this method. dichloromethane 9

µg/L, 1,1-dichloroethane 8 µg/L, 1,2-dichloroethane 13 µg/L.

Under the operating conditions of this method, other halogenated hydrocarbons

do not interfere.

5.1.2 Principle

In a closed headspace bottle, volatile halogenated hydrocarbon molecules

escape from the liquid phase into the gas in the headspace. At a certain

temperature, the molecules of the halogenated hydrocarbon reach a dynamic

equilibrium between the gas and liquid phases, at this time the concentration of

the halogenated hydrocarbon in the gas phase is proportional to its

concentration in the liquid phase. By measuring the concentration of the

halogenated hydrocarbon in the gas phase, it can calculate the mass

concentration of the halogenated hydrocarbon in the water sample.

5.1.3 Reagents and materials
5.1.3.1 Carrier gas and auxiliary gas
5.1.3.1.1 Carrier gas. High purity nitrogen (99.999%).
5.1.3.1.2 Gas. Pure hydrogen ( > 99.6%).
5.1.3.1.3 Combustion supporting gas. Oil-free compressed air, which is purified

by a purge tube containing 0.5 nm molecular sieves.

5.1.3.2 Reagents for preparing standard samples and reagents
5.1.3.2.1 Pure water (fresh deionized water).
5.1.3.2.2 Chromatographic standards (chromatographically pure).

dichloromethane, 1,1-dichloroethane, 1,2-dichloroethane.

5.1.3.3 Reagents and materials for preparing columns
5.1.3.3.1 Columns and fillings are as shown in the relevant contents of 5.1.4.1.3.
5.1.3.3.2 The solvent used for the coating fixative solution. chloroform + butanol

(1 + 1).

5.1.4 Instruments
5.1.4.1 Gas chromatograph
5.1.4.1.1 Hydrogen flame ionization detector.
5.1.4.1.2 Logger or workstation.
5.1.4.1.3 Column

40 min, which can be used for analysis after gas-liquid equilibrium.

5.1.6 Analytical procedures
5.1.6.1 Instrument adjustment
5.1.6.1.1 Gasification chamber temperature. 200 °C.
5.1.6.1.2 Column temperature. 85 °C.
5.1.6.1.3 Detector temperature. 200 °C.
5.1.6.1.4 Gas flow. Carrier gas 50 mL/min; hydrogen 52 mL/min; air 700 mL/min.
5.1.6.1.5 Attenuation. ADJUST the recorder attenuation in accordance with the

content of the measured component in the sample.

5.1.6.2 Calibration
5.1.6.2.1 Calibration method in quantitative analysis. external standard method.
5.1.6.2.2 Standard samples

A. Number of uses. Each time the sample is analyzed, USE the new standard

use solution to draw the standard curve or USE the response factor to make

calculation.

B. Preparation of standard samples. TAKE three 10 mL volumetric flasks, ADD

a few milliliters of distilled water, accurately WEIGH it, respectively ADD one

drop of dichloromethane, 1,1-dichloroethane, and 1,2-dichloroethane.

Accurately WEIGH it, the mass increased is the mass of dichloromethane, 1,1-

dichloroethane, and 1,2-dichloroethane. USE pure water to make the volume

reach to the mark. After calculating the content, respectively TAKE appropriate

amount of this solution, DILUTE it to rho (dichloromethane) = 5 µg/mL, rho (1,1-

dichloroethane) = 7.5 µg/mL, rho (1, 2-dichloroethane) = 7.5 µg/mL, PREPARE it

before use.

C. Conditions for use of standard solutions in gas chromatography.

a The standard solution injection volume is the same as the specimen

injection volume. When measured by the single standard method, the

standard solution response value shall be close to the specimen response

value.

b When the relative standard deviation is less than 10% within the working

range, the instrument is considered to be in a stable state.

c Standard samples and specimen are injected for analysis as far as

possible at the same time.

Under selected chromatographic conditions, formaldehyde, propionaldehyde,

acetone, and butyraldehyde do not interfere with the determination.

7.1.2 Principle

Acetaldehyde and acrolein in water can be directly separated and measured by

gas chromatography with a hydrogen flame ionization detector. The peak order

is acrolein and acetaldehyde.

7.1.3 Reagents and materials
7.1.3.1 Carrier gas and auxiliary gas
7.1.3.1.1 Carrier gas. High purity nitrogen (99.999%).
7.1.3.1.2 Combustion gas. Pure hydrogen ( > 99.6%).
7.1.3.1.3 Combustion supporting gas. Oil-free compressed air, which is purified

by a purge tube fitted with a 0.5 nm molecular sieve.

7.1.3.2 Reagents for preparing standard samples and specimen

pretreatments

7.1.3.2.1 Sodium bisulfite solution [c(NaHSO3) = 0.05 mol/L]
7.1.3.2.2 Iodine standard solution [c (1/2 I2) = 0.10 mol/L], to be calibrated.
7.1.3.2.3 Sodium thiosulfate standard solution [c (Na2S2O3) = 0.10 mol/L], to be

calibrated.

7.1.3.2.4 Starch solution (5 g/L).
7.1.3.2.5 Sulfuric acid solution (1 + 1).
7.1.3.2.6 Standard. Acrolein and acetaldehyde solution [omega(CH3CHO) = 40%].
7.1.3.3 Reagents and materials for preparing columns
7.1.3.3.1 Columns and fills are described in 7.1.4.1.3.
7.1.3.3.2 Solvent used for coating fixative. dichloromethane.
7.1.4 Instruments
7.1.4.1 Gas chromatograph
7.1.4.1.1 Hydrogen flame ionization detector.
7.1.4.1.2 Logger or workstation.

DRY it naturally, PREPARE for use.

8.1.4.5 PTFE membrane or aluminum foil.
8.1.4.6 Constant temperature water bath. Control temperature ± 1 °C.
8.1.5 Samples
8.1.5.1 Sampling method and storage method. TAKE two headspace bottles

containing 0.1 g of sodium thiosulfate to the site, FILL it with water samples,

immediately USE overturn rubber plugs which are wrapped with aluminum foil

(or PTFE membrane) to seal it, BRING it back to the laboratory. If it cannot be

determined immediately, it must be kept in the refrigerator.

8.1.5.2 Water sample pretreatment. After the water sample is sent to the

laboratory, POUR some water sample in the environment without chloroform to

make the water sample in the bottle to 50 mL mark, immediately COVER the

bottle stopper. PLACE one bottle directly in a constant temperature water bath

at 40 °C as the bottle l, USE the injection needle to inject 0.2 mL of sodium

hydroxide solution (8.1.3.2.2) into another bottle, SHAKE it uniformly, PLACE it

into a constant temperature water bath at 40 °C as a bottle II, both of which are

equilibrated in a 40 °C water bath for 2.5 h.

8.1.6 Analytical procedures
8.1.6.1 Instrument adjustment
8.1.6.1.1 Gasification chamber temperature. 200 °C.
8.1.6.1.2 Column chamber temperature. 150 °C.
8.1.6.1.3 Detector temperature. 250 °C.
8.1.6.1.4 Carrier gas flow. 80 mL/min.
8.1.6.2 Calibration
8.1.6.2.1 Calibration method in quantitative analysis. external standard method.
8.1.6.2.2 Standard samples

A. Number of uses. Each time the sample is analyzed, USE the newly prepared

standard use solution.

B. Preparation of standard samples

a. Preparation of standard stock s...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 65 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 5750.10-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
65 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5750.10-2006

$120.00