Valid

GB/T 223.67-2008Iron, steel and alloy -- Determination of sulfur content -- Methylene blue spectrophotometric method (English PDF)

钢铁及合金 硫含量的测定 次甲基蓝分光光度法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 223.67-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 13, 2008

Implementation date

November 1, 2008

Scope

GB/T 223.67-2008 is the English-translated version of 钢铁及合金 硫含量的测定 次甲基蓝分光光度法.

GB/T 223.67-2008 is the Chinese national method for the very low sulfur contents of steel and alloys, measured as methylene blue.

The sample is dissolved in hydrochloric and nitric acid and fumed with perchloric acid, the salts are taken up again in hydrochloric acid, and the sulfur is reduced by a mixture of hydriodic and hypophosphorous acid at 114 °C to 118 °C under a nitrogen stream; the hydrogen sulfide that distils over is absorbed in zinc acetate solution, coloured with N,N-dimethyl-p-phenylenediamine and ferric chloride, and read at 665 nm in a 1 cm cell.

It covers a sulfur mass fraction from 0.0003 to 0.01 percent, with the sample weight set at 1.0 g or 0.50 g, and it tabulates how much niobium, silicon, tantalum and titanium may be present before they interfere; selenium-bearing samples need hydrobromic acid.

Identical to ISO 10701:1994, it replaces GB/T 223.67-1989, was released on 13 May 2008 and has applied since 1 November 2008.

Found what you need?

Document preview — GB/T 223.67-2008

National Standard of the People's Republic of China

ICS
77.080.01

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Principle
  • 4 Reagent
  • 5 Device
  • 6 Take samples
  • 7 Operating procedures
  • 8 Results calculation
  • 9 Special circumstances
  • 10 Operating Procedure Comments
  • 11 Test report
  • Appendix B (Informative)

Foreword

This part of GB/T 223 is equivalent to ISO 10701.:1994 "Determination of sulfur content of steel and alloy Methylene blue spectrophotometric law". This section is equivalent translation ISO 10701.:1994.

For ease of use, this section made the following editorial changes.

a) Replace the word "international standard" with "this part";

b) Use the decimal point "." instead of the decimal point ",";

c) Delete the preface to the International Standard.

This Part Replaces GB/T 223.67-1989 "Methods for chemical analysis of iron, steel and alloy - The reductive distillation - Methylene blue spectrophotometric method for the determination of sulfur Quantity ", compared with the main changes made to the following.

--- Determination range from 0.001% to 0.030% adjusted to 0.0003% ~ 0.01%;

--- "Use bromine to make sulfur oxidation, and evaporate to drive nitric acid" to "use perchloric acid to smoke and drive away nitric acid";

--- The amount of sample is adjusted from 1.0000g to 0.50g and 1.0g respectively according to the content difference;

--- Distillation and purification devices have been changed. This part of Appendix A, Appendix B are informative appendix.

0.00074

NOTE 1 Two determinations in three determinations are made under the repeatability conditions specified in ISO 5725, that is, by the same investigator, using the same instrument, the same

Test conditions, the same calibration, measured in the shortest possible time.

Note 2. The third determination by the Note 1 Noteworthy staff, using the same instrument, at different times (different days), with a new calibration. The result, the laboratory reproducibility limit (RW) was calculated.

0.00095

7) NBS348a (stainless steel)

8) JSS654-10 (stainless steel)

9) JSS611-8 (high speed steel)

10) ECRM191-1 (high silicon steel)

11) ECRM285-1 (high alloy steel)

12) ECRM481-1 (ductile iron)

13) JSS650-9 (stainless steel)

14) ECRM235-1 (high alloy steel)

15) JSS654-7 (stainless steel)

16) NBS339 (selenium-containing stainless steel)

0.00108

S, 1. The average of the measured data on the same day.

S, 2. The average of different days measured data. a sample amount = 0.25 g.

Note: The following four samples have been omitted from the regression calculations for the following reasons.

Sample 1) (pure iron). sulfur content lower than the lower limit of this method; Sample 7) (stainless steel). titanium content of 2.1% (mass fraction);

Sample 10) (high silicon steel). silicon content of 3.7% (mass fraction); Sample 12) (ductile iron). Silicon content 2.3% (mass fraction).

1 Scope

GB/T 223 provisions of this part of the Methylene blue spectrophotometric determination of sulfur content in steel and alloy.

This section applies to steel and alloy mass fraction of 0.0003% ~ 0.01% sulfur content determination. Niobium, Silicon, Tantalum and Titanium to Sulfur Determination of interference. According to the content of interfering elements, the applicable range and the amount of sample are given in Table 1.

2 Normative references

The following documents contain provisions which, through reference in this Part of GB/T 223, become the provisions of this section. Any reference to the date of the citation All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to be reached under this section The parties to the agreement study whether the latest versions of these documents are available. For undated references, the latest version applies to this book section.

ISO 377-2. 1989 Selection and preparation of test specimens for sample and forged steels - Part 2. Samples for determination of chemical composition

ISO 385-1. 1984 Laboratory glassware burets - Part 1. Basic requirements Laboratory glassware Monoscript pipettes

ISO 1042. 1983 Laboratory glassware single standard line volumetric flask

ISO 3696. 1987 Analysis of laboratory water specifications and test methods

ISO 5725. 1986 Precision of measurement methods - Repeatability and reproducibility of standard measurement methods are determined by interlaboratory tests

3 Principle

The sample is dissolved in a mixed acid of hydrochloric acid and nitric acid, evaporated to white smoke with perchloric acid to drive off hydrochloric acid and nitric acid. Dissolved salt with hydrochloric acid to hydrogen A mixture of iodic acid and hypophosphorous acid was used as a reducing agent, and hydrogen sulfide generated under a stream of nitrogen was distilled and taken up in a zinc acetate solution. Through with N, N-dimethyl-p-phenylenediamine solution and the ferric solution to produce methine blue. Absorbance was measured at a wavelength of 665 nm.

4 Reagent

Unless otherwise stated, use only analytical reagents of very low sulfur content, approved analytical reagents and newly prepared ISO 3696 Level 2 water.

4.1 Hydrochloric acid, p approximately 1.19 g/mL.

4.2 Hydrochloric acid, rho about 1.19g/mL, diluted to 1 +15.

4.3 Perchloric acid, rho about 1.54g/mL.

4.4 Hydrobromic acid, p about 1.48 g/mL.

4.5 hydrochloric acid - nitric acid mixed acid. Mix 1 volume of hydrochloric acid (4.1) with 1 volume of nitric acid (rho of about 1.40/mL) and prepare beforehand. Open the heating mantle, heat to boiling, and then keep slightly boiled for about 120 min at a temperature of about 115 ° C in a stream of nitrogen. After purification (see 10.3), turn off the heating cover. The solution is then cooled and stored in a brown bottle.

4.6 Reducing agent solution..200 mL of hydriodic acid [about 57% (mass fraction)] and 50 mL of hypophosphorous acid [about 50% (mass fraction)] were transferred Into the purification device (see Figure 1). Flush with nitrogen at a flow rate of 100 mL/min for 10 min to mix the acid and expel the air from the system.

4.7 Absorption solution. 5g of zinc acetate dihydrate [(CH3COO) 2Zn · 2H2O] was dissolved in 400mL of water, 200mL of hydrogen peroxide Sodium solution (30g/L) and 70g of ammonium chloride, then diluted with water to 1000mL, and mix.

4.8 iron solution, 10g/L. Weigh 1.00g sulfur-free pure iron, transferred to a 300mL beaker, add 20mL hydrochloric acid (rho about 1.19g/mL, diluted to 1 + 1), covered with a watch glass, heated to dissolve, and slightly boiled for about 10min. Then, 2mL of nitric acid was added dropwise (rho approx 1.40 g/mL) so that the iron is oxidized. Boil to drive nitrogen oxides, cooled to room temperature. Transfer to 100mL single-labeled volumetric flask, diluted with water To the mark, mix well.

4.9 Ferric chloride solution. 1g of ferric chloride hexahydrate (FeCl3 · 6H2O) was dissolved in about 40mL of water, 10mL of hydrochloric acid was added (4.1), diluted with water to 100mL, mix well.

4.10 N, N-dimethyl-p-phenylenediamine solution, hydrochloric acid medium. 0.5 g of N, N-dimethyl-p-phenylenediamine hydrochloride [NH2C6H4N (CH3) 2 · 2HCl] dissolved in about 100mL water, add 230mL hydrochloric acid (4.1), diluted with water to 500mL, and mix.

4.12 Nitrogen.

4.11 Sulfur standard solution

4.11.1 sulfur stock solution, equivalent to 1g sulfur per liter. Weigh pre-dried at 110 °C 2h, and cooled to room temperature in a desiccator of potassium sulfate 5.4352g [purity >= 99.5% (mass fraction)], dissolved in water, quantitative transferred to 1000mL single-labeled line volumetric flask, diluted to the mark, mixed uniform. This stock solution 1mL contains 1mg sulfur.

4.11.2 Sulfur standard solution

A, equivalent to 10mg sulfur per liter. Pipette 10.00mL sulfur stock solution (4.11.1) placed in 1000mL single standard Line capacity bottle, diluted with water to the mark, mix well. 1 mL of this solution contains 10 µg sulfur.

4.11.3 Sulfur standard solution

B, equivalent to 1mg sulfur per liter. Pipette 10mL standard solution (4.11.2) placed 100mL single standard line capacity Bottle, diluted with water to the mark, mix well. Prepared before use. 1 mL of this solution contains 1 µg sulfur.

5 Device

All glass feelers shall comply with Class A of ISO 385-1, ISO 648 or ISO 1042. Normal laboratory equipment and the following instruments are used.

5.2 spectrophotometer, absorbance can be measured at a wavelength of 665nm.

5.0 A Zero calibration solution

5.1 Reductive distillation unit in millimeters

Assemble the reductive distillation unit as shown in Fig. 2, all using a close-to-ground glass interface. If this unit is used for the first time, or for a long time no Use, blank test should be repeated until a stable low blank value.

5.1.1 Decomposition flask, the volume of about 300mL

5.1.2 Reflux condenser, about 150mm

5.1.3 Gas cylinder, the volume of about 150mL

5.1.4 Absorption bottle, 20mL or 100mL single-labeled volumetric flask

6 Take samples

Take sample according to ISO 377-2 or the appropriate national standard of steel.

7 Operating procedures

Warning. Perchloric acid vapor can cause explosions when ammonia, nitrous acid smoke or organic matter are present.

7.1 Sample

According to the estimated sulfur content, weighed sample, accurate to 1mg.

a) Sulfur content (mass fraction) is 0.0003% to 0.0010%, and the amount of sample is about 1.00 g.

b) sulfur content (mass fraction) is 0.0010% ~ 0.010%, the amount of sample is about 0.50g.

7.2 Blank test

Follow the same procedure using the same amount of all reagents and perform a blank test parallel to the sample. Recommended. For the sulfur content (mass points ) Is less than 0.001%, the blank value should not exceed 0.7µg of sulfur. For the sulfur content (mass fraction) of 0.001% to 0.010%, the blank The value should not exceed 1.5 µg of sulfur.

7.3 Determination

7.3.1 Preparation of test solution

7.3.1.1 Place the sample (7.1) in a disintegration flask (5.1.1) and add 15 mL hydrochloric acid-nitric acid mixed acid (4.5). Place at room temperature After 30 min, heat gently until the dissolution reaction has stopped.

7.3.1.2 Pipette 5.0mL perchloric acid (4.3) and 1.0mL iron solution (4.8), heated to evaporate until white smoke appears. After cooling, Add 5 mL hydrochloric acid (4.1). (For a possible modification of this step, see 9.) Heat again to smoke on a hot plate at about 300 ° C. Of course After continued evaporation of perchlorate white smoke to make do.

7.3.1.3 Remove the cooling, add 10mL hydrochloric acid (4.1), heated to dissolve salts, cooled to room temperature.

7.3.2 Reduced distillation

Add 20 mL reducing agent solution (4.6) to the disintegration flask (5.1.1) and allow to stand for 10 min. Add 30mL of water to the scrubbing flask, root Depending on the sulfur content to be tested, place an appropriate volume of absorbent solution (4.7) in the absorbent container (5.1.4) as follows.

a) The content of sulfur (mass fraction) is less than 0.0010%. Add 10mL absorption solution (4.7) into 20mL absorption bottle.

b) The content of sulfur (mass fraction) is 0.0010% ~ 0.010%, add 50mL absorption solution (4.7) in 100mL absorption Bottle Water was introduced into the condenser and connected to a decomposition flask (5.1.1) equipped with a test solution. Nitrogen was passed into the apparatus at a flow rate of 100 mL/min, as shown in the figure 2 shows. The test solution was heated to 114 °C ~ 118 °C for 30min. This can usually be done by setting the hotplate temperature to 250 ° C (see 10.2)

To be done. The generated gas is carried by the nitrogen carrier gas into the absorption bottle through the scrubber.

7.3.3 Color
7.3.3.1 Sulfur content (mass fraction) less than or equal to 0.0010%

Remove 20 mL of the absorbent bottle (5.1.4) and the gas inlet tube from the device. The tube of liquid droplets into the absorption solution, with a trace amount of migration Dispenser Add 1.0 mL of hydrochloric acid (4.2) from the upper end of the tube to the inner surface of the tube and rinse with 1 mL of water.

Remove the gas inlet tube, gently swirl the 20 mL absorption bottle and place in a thermostat at 25 ° C for 20 min. Then in the absorption bottle (5.1.4) Add 2.0 mL N, N-dimethyl-p-phenylenediamine solution (4.10) and shake gently. Immediately add 0.4mL ferric chloride solution (4.9), intense shaking 1min. Dilute to the mark with water and mix well. Place 15min.

7.3.3.2 Sulfur content (mass fraction) of 0.0010% ~ 0.010%

Remove 100 mL of the absorbent bottle (5.1.4) and the gas inlet tube from the device. The tube of liquid droplets into the absorption solution, with a trace amount of migration Add 1.0 mL of hydrochloric acid (4.2) from the upper end of the tube to the inner surface of the tube and rinse with 1 mL or 2 mL of water.

Remove the gas inlet tube and gently swirl the 100 mL absorption bottle and place in a thermostat at 25 ° C for 20 min. Then in the absorption bottle (5.1.4) 10.0 mL N, N-dimethyl-p-phenylenediamine solution (4.10) was added and shaken gently. Immediately added 2.0mL ferric chloride solution (4.9), intense shaking 1min. Dilute to the mark with water and mix well. Place 15min.

7.3.4 Spectrophotometric measurement

After zeroing the spectrophotometer (5.2) with water as reference, a 1 cm dish was used and spectrophotometry was performed at a wavelength of 665 nm.

7.4 Calibration curve establishment

7.4.1 Preparation of calibration solution

1.0mL iron solution (4.8) were placed in six decomposition flask (5.1.1), according to Table 2 were added to the corresponding volume of sulfur standard solution liquid. Then add 15mL hydrochloric acid - nitric acid mixed acid (4.5), 5.0mL perchloric acid (4.3), heated to smoke. The following press 7.3.1.2 To 7.3.3.

7.4.2 Spectrophotometric measurement

Zero calibration solution (see Table 2) as a reference to the spectrophotometer (5.2) zero after the absorption with 1cm dish, at a wavelength of 665nm into Spectrophotometric determination.

7.4.3 Calibration curve drawing

Draw a calibration curve for absorbance of sulfur concentration, with the sulfur concentration developed for every 20 mL (see 7.3.3.1) or per 100 mL (see 7.3.3.2) Liquid sulfur content (µg) said.

8 Results calculation

8.1 Calculation method

According to the calibration curve (see 7.4.3), the absorbance of the color developing solution as determined in 7.3.4 (see 7.3.3.1 or 7.3.3.2) is converted to the corresponding Of the mass, expressed as the mass of sulfur (µg).

Sulfur content, expressed in terms of mass fraction (%), is given by equation (1)

106 × (1) Where.

8.2 Precision

This part of the precision test to 16 sulfur levels, carried out in 11 or 13 laboratories, each laboratory for each level of sulfur content determination 3 times (see note 1 and note 2).

The samples used are shown in Table A of Appendix A. 1. According to ISO 5725, the results obtained are statistically processed.

9 Special circumstances

For samples containing selenium, the second paragraph of 7.3.1 "After cooling, add 5mL hydrochloric acid (4.1)" should be changed to "After cooling, add 5mL hydrochloric acid (4.1) and 5 mL hydrobromic acid (4.4). "

10 Operating Procedure Comments

10.1 Due to the high sensitivity of this method, it is important to eliminate sources of sulfur contamination. In fact, it is possible to provide specialized rooms for such analysis More effective. If the tester determines that two reagents are blank, the lower one is usually the correct one. When using the new King carefully When washing the flask, fake sulfur contamination was observed.

It is important that all sample processing should be performed in a rigorous laboratory environment (no soot and any sulfur or sulfur compounds Of steam or dust).

In order to make the sulfur blank low and constant (eg = 0.5 µg, sigma = 0.15 µg sulfur), care should be taken when choosing the acid, but not required Purification by distillation.

10.2 From a chemical reaction point of view, the reduction of sulphate to hydrogen sulphide is a difficult reaction. In order to ensure the sulfur recovery, should be strictly controlled Reaction conditions. The best reduction temperature is 114 °C ~ 118 °C. If the reducing solution is over-diluted by the sample solution, its boiling point is reduced, too The original reaction rate slowed down slightly. Above 120 ° C, the acidic mixture has hypophosphorous acid decomposition and phosphine formation.

The temperature required for the electric furnace should be set by inserting a pre-blank test of the thermometer in the heating solution.

10.3 To verify the purification, connect a hydrogen sulfide trap (see Figure 1) containing 10 mL of absorbent (4.7) and continue heating for 30 min.

Remove the collector. According to 7.3.3.1 color, according to the need to use grinding glass stopper. Add 8mL water, dilute to about 20mL. put Set 15min.

After zeroing the spectrophotometer (5.2) with water as reference, a 1 cm dish was used and spectrophotometry was performed at a wavelength of 665 nm.

Purification is complete when the measured absorbance value is less than 0.055 (corresponding to 1 µg of sulfur).

10.0

0.0010 ~ 0.010

11 Test report

The test report should include the following.

a) Identification of materials, laboratory and analysis date;

b) to comply with the provisions of this section;

c) analysis results and their representation;

d) the anomalies observed in the assay;

e) Actions or optional actions that may have an impact on the analysis but are not covered by this section. Appendix A. (Informative) Additional information on international cooperation tests

The test results are documented in ISO /T C17/SC1N839, March.1990 and ISO /T C17/SC1N915, February.1992 Reported. Pictorial precision data in Appendix B.

Appendix B (Informative)

Precision data illustration lgR = 0.6756lgS, 1-1.4005 lgRW = 0.5467lgS, 2-2.0368 among them.

S, 1. The average sulfur content obtained on the same day, expressed in terms of mass fraction;

S, 2. The average sulfur content obtained on different days, expressed in terms of mass fraction. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

ISO 377-2 · ISO 385-1 · ISO 1042 · ISO 3696 · ISO 5725

Cited by

Editions of GB/T 223.67

EditionTitleRevisionStatus
GB/T 223.67-2008Iron, steel and alloy -- Determination of sulfur content -- Methylene blue spectrophotometric method—Current
GB/T 223.67-1989Methods for chemical analysis of iron, steel and alloy--The reducing distillation-methylene blue photometric method for the determination of sulfur content—Superseded

This page sells the current edition, GB/T 223.67-2008. Earlier editions are listed for reference only.

How to Download GB/T 223.67-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation.

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 223.67-2008

$55.00