GB/T 22158-2021Code for fire protection design of nuclear power plant (English PDF)
核电厂防火设计规范
This is a limited preview
Buy now to download the full PDF (51 pages)
Need quotation for your management?
Get a formal quotation for GB/T 22158-2021 in 30 minutes.
Issued by
State Administration for Market Regulation; Standardization Administration of China
Level / Type
National · Recommended
Issue date
October 11, 2021
Implementation date
May 1, 2022
Scope
GB/T 22158-2021 is the English-translated version of 核电厂防火设计规范.
GB/T 22158-2021 is the Chinese standard "Code for fire protection design of nuclear power plant".
Its scope clause reads: This document specifies the basic requirements for the internal fire protection and explosion-proof design of nuclear power plants, mainly including the general requirements for fire protection design and the protection of the general layout.
Fire design, fire prevention and limitation of fire spread, fire evacuation, automatic fire alarm system, fire water supply and fire extinguishing system, ventilation, fire prevention and prevention Smoke exhaust, fire safety analysis, internal explosion-proof design, and fire protection design requirements for key areas and equipment, etc. This document is applicable to newly built land-based fixed thermal neutron reactor nuclear power plants in China.
Other types of nuclear power plants and nuclear facilities can refer to this regulation. Fan carries on the design. This document is mainly aimed at the internal fire protection of important nuclear safety buildings (structures) (such as nuclear island plants, important plant water system pump rooms and corridors, etc.)
And explosion-proof design, the fire protection design of conventional islands and supporting facilities and workshops meets the requirements in Chapter 4, Chapter 5 and Chapter 13 of this document (specially It specifically refers to the requirements of important nuclear safety structures (except for the requirements) on the basis of compliance with other relevant domestic design standards. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 22158-2021
National Standard of the People's Republic of China
- ICS
- 27.120.20
- Classification
- F69
Issued by: State Administration for Market Regulation; Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements for fire protection design
- 5 Fire protection design of general layout
- 6 Fire prevention and limitation of fire spread
- 7 Fire Evacuation
- 8 Automatic fire alarm system
- 9 Fire water supply and fire extinguishing system
- 10 Ventilation, fire prevention and smoke exhaust
- 11 Fire safety analysis
- 12 Internal explosion-proof design
- 13 Fire protection design requirements for key areas and equipment
- 14 Quality Assurance
- Appendix A (normative) Seismic requirements
- Appendix B (Normative) Commissioning and Periodic Test
- Appendix C (informative) Technical requirements for fireproof coating of cable tray section
- Appendix D (informative) Types of fire risk
1 Scope
This document specifies the basic requirements for the internal fire protection and explosion-proof design of nuclear power plants, mainly including the general requirements for fire protection design and the protection of the general layout.
Fire design, fire prevention and limitation of fire spread, fire evacuation, automatic fire alarm system, fire water supply and fire extinguishing system, ventilation, fire prevention and prevention
Smoke exhaust, fire safety analysis, internal explosion-proof design, and fire protection design requirements for key areas and equipment, etc.
This document is applicable to newly built land-based fixed thermal neutron reactor nuclear power plants in China. Other types of nuclear power plants and nuclear facilities can refer to this regulation.
Fan carries on the design.
This document is mainly aimed at the internal fire protection of important nuclear safety buildings (structures) (such as nuclear island plants, important plant water system pump rooms and corridors, etc.)
And explosion-proof design, the fire protection design of conventional islands and supporting facilities and workshops meets the requirements in Chapter 4, Chapter 5 and Chapter 13 of this document (specially
It specifically refers to the requirements of important nuclear safety structures (except for the requirements) on the basis of compliance with other relevant domestic design standards.
2 Normative references
The content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations
Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
This document.
GB/T 18380 (all parts) Cable and optical cable burning test under flame conditions
GB/T 19216 (all parts) Cable and optical cable line integrity test under flame conditions
GB/T 40620 Nuclear Power Plant Fire Hazard Analysis Guide
GB 50016 Code for fire protection of building design
GB 50058 Code for Design of Electric Power Installations in Explosive Hazardous Environments
GB 50084 Design Code for Automatic Sprinkler System
GB 50140 Code for Design of Building Fire Extinguisher Configuration
GB 50151 Code for design of foam fire extinguishing system
GB 50219 Technical Specification for Water Spray Fire Extinguishing System
GB/T 50294 Code for General Plan and Transportation Design of Nuclear Power Plant
GB 50745 Code for fire protection design of conventional islands in nuclear power plants
GB 50974 Technical Specification for Fire Water Supply and Hydrant System
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Flame retardant
The property of an object to extinguish, reduce or significantly retard the combustion of certain materials.
3.2 Firearea
In the factory building or part of the factory building constructed to prevent the fire from spreading within the specified time, the fireproof zone can be composed of one or more rooms.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 51 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 40620Guidelines for fire hazard analyses in nuclear power plants
- GB 50016[2018 Edition of GB 50016-2014] Code for Fire Protection Design of Buildings [Code of Design on Building Fire Protection and Prevention]
- GB 50058Code for design of electrical installations in explosive atmospheres
- GB 50084Code for design of sprinkler systems
- GB 50140Code for Design of Extinguisher Distribution in Buildings
- GB 50151Code for installation and acceptance of foam extinguishing systems
GB/T 18380 · GB/T 19216
Cited by
- NB/T 20532-2018Commissioning technical guidelines for fire protection system of nuclear power plant
- NB/T 20449-2017Design criteria for fuel oil system of the emergency diesel generator of nuclear power plant
- NB/T 20388-2016Specifications for construction and acceptance for openings sealing in nuclear island of PWR nuclear power plant
- NB/T 20340-2015Technical specification for installation and acceptance of passive fire protection structure of PWR nuclear power plant
- NB/T 25045-2015Performance assessment and management guideline of fire protection features for nuclear power plant
- NB/T 20280-2014Design criteria of boron recycle system for PWR nuclear power plants
Similar standards
Editions of GB/T 22158
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 22158-2021 | Code for fire protection design of nuclear power plant | current edition | Current |
| GB/T 22158-2008 | Design Standard of Fire Protection in Nuclear Power Plant | previous edition | Superseded |
This page sells the current edition, GB/T 22158-2021. Earlier editions are listed for reference only.
How to Download GB/T 22158-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 50016-2014 — Code for Fire Protection Design of Buildings (2018 Edition)
GB 50016-2018 — [2018 Edition of GB 50016-2014] Code for Fire Protection Design of Buildings [Code of Design on Building Fire Protection and Prevention]
GB 50058-2014 — Code for design of electrical installations in explosive atmospheres
Secure payment via Stripe
Payments accepted
GB/T 22158-2021