NB/T 10204-2019Technical requirements for interface equipment of distributed PV generation system connected to low voltage power distribution networks (English PDF)
分布式光伏发电低压并网接口装置技术要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for NB/T 10204-2019 in 30 minutes.
Issued by
NEA
Level / Type
Industry · Recommended
Issue date
June 4, 2019
Implementation date
October 1, 2019
Scope
NB/T 10204-2019 is the English-translated version of 分布式光伏发电低压并网接口装置技术要求.
NB/T 10204-2019 is the Chinese energy industry standard for the interface equipment that connects distributed photovoltaic generation systems to low-voltage distribution networks at 400 V and below.
It classifies the devices as indoor or outdoor and as 220 V single-phase or 380 V three-phase, and sets use conditions such as ambient temperature, altitude, seismic resistance, pollution degree and IP rating.
Requirements address enclosure structure, earthing, mechanical strength, insulation and electromagnetic compatibility, and functions including disconnection, protection, data acquisition, monitoring, communication and storage.
Tests, inspection rules and marking, packaging and transport complete it, and designers, manufacturers and test labs use it. Issued on 4 June 2019, it has applied since 1 October 2019.
Found what you need?
Document preview — NB/T 10204-2019
National Standard of the People's Republic of China
- Classification
- K 45
Issued by: National Energy Administration of the People's Republic of China
Contents
- 1 Scope1
- 2 Normative reference documents1
- 3 Terms and Definitions1
- 4 Device classification2
- 5 Conditions of use2
- 6 Structure, safety and electromagnetic compatibility requirements2
- 7 Functional requirements4
- 8 Experiments5
- 9 Inspection rules5
- 10 Marks, packaging, storage, transportation7
- references8
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Please note that certain contents of this standard may involve patents. The issuing organization of this standard does not bear the responsibility for identifying these patents.
This standard was proposed and interpreted by the China Electricity Council.
Drafting organizations of this standard. Nanjing Nanrui Relay Electric Co., Ltd., China Electric Power Research Institute Co., Ltd., Inner Mongolia Electric Power Research Institute Research Institute, State Grid Zhejiang Electric Power Co., Ltd. Jiaxing Power Supply Company, Beijing Qunling Energy Technology Co., Ltd.
1 Scope
This standard specifies the classification, use conditions, structure, safety, and electromagnetic Compatibility requirements, device functions, test methods, inspection rules, and requirements for marking, packaging, storage, and transportation.
This standard is applicable to grid-connected interface devices of distributed photovoltaic power generation systems with voltage levels of 400V and below connected to low-voltage distribution networks (below Referred to as interface device), as the basis for the design, manufacture, inspection and test of the interface device.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document.
For undated references, the latest version (including all amendments) applies to this document.
GB/T 191 Packaging, Storage and Transportation Graphic Mark Standard
GB/T 4208 enclosure protection grade (IP code)
GB/T 4798.2 Environmental conditions for application of electrical and electronic products Part 2: Transportation
GB/T 7251.1-2013 Low-voltage switchgear and control equipment Part 1: General
GB/T 13384 General technical conditions for packaging of mechanical and electrical products
GB/T 16935.1-2008 Insulation coordination of equipment in low-voltage systems Part 1: Principles, requirements and tests
GB/T 17626.2-2006 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test
GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology Radio frequency electromagnetic field radiation immunity test
GB/T 17626.4-2008 Electromagnetic compatibility test and measurement technology Electrical fast transient pulse group immunity test
GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology surge (impact) immunity test
GB/T 17626.6-2008 Electromagnetic compatibility test and measurement technology Radio frequency field induced conducted disturbance immunity
GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test
GB/T 17626.12-2013 Electromagnetic compatibility test and measurement technology Ring wave immunity test
DL/T 478 General technical requirements for relay protection and safety automatic devices
DL/T 634.5104 Telecontrol Equipment and System Part 5-104.The transmission protocol adopts the IEC 60870-5-101 network of the standard transmission protocol set Network access
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Distributed photovoltaic generation
Constructed near the user's site, the operation mode is based on the user's spontaneous self-use, the excess power is connected to the Internet, and the balance adjustment is used on the power distribution system side. Characteristic photovoltaic power generation facilities.
3.2 Interface equipment
Distributed photovoltaic power generation system is connected to the integrated device of low-voltage power distribution network, with interruption, protection, acquisition, monitoring, communication, storage, etc Features.
4 Device classification
4.1 Divided into the following types according to the place of use.
a) Outdoor type; b) Indoor type.
4.2 Divided into the following types according to the number of phases connected to the distribution network.
a) 220V single-phase type;
b) 380V three-phase type.
5 Conditions of use
5.1 Environmental conditions
The device should work normally under the following climatic conditions.
a) Ambient temperature. -10°C~ 55°C (indoor type), -25°C~ 70°C (outdoor type);
b) Relative humidity. <=95% (25°C);
c) Altitude. below 2000m;
d) Seismic resistance. horizontal acceleration 0.30g, vertical acceleration 0.15g;
e) Pollution degree. not exceeding the level 3 specified in GB/T 16935.1-2008;
f) Degree of protection. indoor type shall not be lower than IP20 specified in GB/T 4208; outdoor type shall not be lower than IP54 specified in GB/T 4208.
5.2 Conditions for access to the grid
The device should be able to work normally under the following conditions of access to the power grid.
a) Rated frequency of power grid. 50 Hz, allowable deviation ±1Hz;
b) Rated power grid voltage. three-phase 380V or single-phase 220V. The allowable deviation of 220 V voltage is -15%~10% of the rated voltage, The allowable deviation of 380V voltage is -10%~10% of the rated voltage.
6 Structure, safety and electromagnetic compatibility requirements
6.1 Structure and appearance requirements
The device structure should meet the requirements specified in 8.1.1 of GB/T 7251.1-2013. The structure and appearance of the device should also meet the following requirements.
a) The box body of the device should be firm and flat, the surface should be smooth and flat, and the color of the coating should be uniform without obvious color difference and glare.
The surface should be free of defects such as sand, rust, wrinkles and flow marks.
b) The panel of the device cabinet should be flat, and the text and symbols should be clear, tidy, standardized and correct.
c) Signs, signs and markings should be complete and clear.
d) Various door locks and switches should be easy to operate, flexible and reliable.
e) The device should be marked with a warning sign indicating that the metal parts in the box are live.
6.2 Grounding
The conductive box parts in the device should be effectively grounded. The resistance from any point in the grounding circuit to the grounding terminal should not exceed 0.1ohm.
6.3 Mechanical requirements
The device should be able to withstand the mechanical vibration and shock requirements specified in DL/T 478, and be suitable for the normal transportation and operation of the device.
6.4 Insulation performance
6.4.1 Insulation resistance
The insulation resistance between the conductive circuit of the device and the ground should not be less than 0.5Mohm.
6.4.2 Insulation strength
The device should be able to withstand a power frequency AC voltage or equivalent DC voltage with a frequency of 50 Hz and a duration of 1 min. During the test, ensure that there is no breakdown.
No arcing, leakage current less than 20 mA; the voltage level of the dielectric strength test should meet the requirements of Table 1.
Note: In principle, the media strength of the whole machine should be tested once according to the above indicators. If necessary, the test can be repeated, and the test voltage is 75% of the specified value.
6.4.3 Clearance and creepage distance
The electrical clearance and creepage distance should meet the requirements of Table F.7 and Table F.4 of GB/T 16935.1-2008. The minimum creepage distance should not be less than in the air Minimum electrical clearance.
6.5 EMC performance
6.5.1 Electrostatic discharge immunity
The device should be able to withstand the electrostatic discharge immunity test of test level 3 specified in GB/T 17626.2-2006, and the test results should meet
GB/T 17626.2-2006 Chapter 9 Class b requirements.
6.5.2 Radio frequency electromagnetic field radiation immunity
The device should be able to withstand the radio frequency electromagnetic field radiation immunity test of test level 3 specified in GB/T 17626.3-2016, and the test results should Meet the requirements of category a in Chapter 9 of GB/T 17626.3-2016.
6.5.3 Electrical fast transient pulse group immunity
The device should be able to withstand the electrical fast transient pulse group immunity test of test level 3 specified in GB/T 17626.4-2008, the test results It shall meet the requirements of category a in Chapter 9 of GB/T 17626.4-2008.
6.5.4 Surge (impact) immunity
The device should be able to withstand the surge (impact) test specified in GB/T 17626.5-2008 (apply a 1.2/50us surge signal to the power port, Line-to-line ±1 kV, line-to-ground ±2 kV), the test results should meet the requirements of category b in Chapter 9 of GB/T 17626.5-2008.
6.5.5 Radio frequency conducted immunity
The device should be able to withstand the radio frequency conducted immunity test of test level 3 specified in GB/T 17626.6-2008, and the test results should meet Type a requirements in Chapter 9 of GB/T 17626.6-2008.
6.5.6 Power frequency magnetic field immunity
The device should be able to withstand the power frequency magnetic field immunity test of test level 3 specified in GB/T 17626.8-2006, and the test results should meet Class a requirements in Chapter 9 of GB/T 17626.8-2006.
6.5.7 Ring wave immunity
The device should be able to withstand the ring wave immunity test of test level 3 specified in GB/T 17626.12-2013, and the test results should meet
GB/T 17626.12-2013 Chapter 9 Class A requirements.
7 Functional requirements
7.1 General requirements
The device should have grid connection/exit, restore grid connection, undervoltage protection, overvoltage protection, overcurrent protection, data acquisition, data storage, communication Function, should have reverse power protection, human-computer interaction function.
7.2 Power adaptability
The power input voltage of the device should be AC220V/AC380V, the allowable deviation is -20%~20%; the frequency is 50Hz, and the allowable deviation is -2.5Hz~1.5Hz.
7.3 Control and protection functions
7.3.1 Grid connection/exit function
The device should have the grid-connected/exit function, which is realized by the switch element in the device, and the switch element meets the following requirements.
a) There should be obvious instructions for grid connection/exit;
b) Switchgear with reverse connection capability of power supply and load should be used. When switchgear without reverse connection capability is used, the power supply The terminal should be connected to the grid side;
c) The switching element should have a short-circuit quick-break function.
7.3.2 Restore grid connection function
The device shall have the function of automatic recovery and grid connection. The delay time for automatic recovery and grid connection can be set.
7.3.3 Undervoltage protection function
The device shall have undervoltage protection function. When the grid voltage is less than the set voltage, the device should disconnect from the grid within the set time.
7.3.4 Overvoltage protection function
The device shall have an overvoltage protection function. When the grid voltage is greater than the set voltage, the device should disconnect from the grid within the set time.
7.3.5 Overcurrent protection function
The device shall have an overcurrent protection function. When the grid connection point current is greater than the set current, the device should be disconnected from the grid within the set time Connection.
7.3.6 Reverse power protection function
The device should have reverse power protection. When it is monitored that the power of the grid-connected point is reversed to the grid, the device should be disconnected from the grid within the set time Connection.
7.4 Data collection and storage
7.4.1 Data Collection
The data sampling interval should not be greater than 5 minutes, and the collected information should at least include the following.
a) Electrical analog quantities. voltage, current, frequency, active power, and reactive power;
b) Status quantity. switch status, fault information.
7.4.2 Data Storage
The data storage function requirements of the interface device are as follows.
a) The data storage interval should not be greater than 5 minutes, and the stored data information includes the amount of data collected;
b) The maximum storage time of historical data is more than 3 months, and the storage time of historical data of device power failure is at least 1 year. Convenient to transfer or export.
7.5 Communication function
The interface device should have a communication interface with the photovoltaic power generation system and the information acquisition and control platform of the distribution network, and meet the following requirements.
a) The interface device has at least one interface to communicate with the photovoltaic power generation system;
b) The interface device has at least one interface to communicate with the power grid;
c) The interface device should have a wireless communication interface, which can realize the user's remote monitoring function.
7.6 Human-computer interaction
The interface device should have a human-computer interaction function, and the human-computer interaction interface can display the device status, communication status, and collected information.
9 Inspection rules
9.1 Inspection classification
Device inspection is divided into type inspection, factory inspection and on-site inspection, and the inspection items shall meet the requirements of Table 2.
9.2 Type inspection
Type inspection should be carried out in one of the following situations.
a) Before new product identification;
b) When there are major changes in structure, material, process, firmware, etc., which may affect product performance;
c) When the product has been stopped for more than 1 year and then resumed production.
The type inspection qualification shall comply with the regulations of DL/T 478.
9.3 Factory inspection
Before leaving the factory, each device shall be inspected by the manufacturer's quality inspection department and confirmed to be qualified before leaving the factory. Factory qualified after inspection The device should have a product certificate that proves that the device is qualified.
9.4 Site inspection
After the device is installed on site and before it is put into operation, it should be tested on site.
10 Marking, packaging, storage and transportation
10.1 Logo
10.1.1 Each device must be provided with a long-lasting and clear logo or nameplate on a prominent part of the chassis, the logo is as follows.
a) Product name and model;
b) The full name and trademark of the manufacturer;
c) Main parameters;
d) External terminal and interface mark;
e) Factory date and serial number.
10.1.2 There are receipt and delivery signs, packaging storage and transportation signs and warning signs on the outer packaging of the device, which shall be implemented in accordance with the relevant regulations of GB/T 191.
10.2 Packaging
10.2.1 The technical documents supplied with the product include.
a) Installation instructions;
b) Product instruction manual;
c) Technical indicators and parameters;
d) Product quality certificate;
e) Warranty card;
f) User opinion survey form.
10.2.2 Product packaging should comply with the relevant regulations of GB/T 13384.
10.3 Storage
The device should be placed in the original packaging box, stored in air circulation, ambient temperature -25°C~55°C, relative humidity not more than 85%, no harmful Storehouses containing gases, flammable and explosive materials and corrosive materials, and should not be subjected to strong mechanical vibrations, shocks and strong magnetic fields.
10.4 Transportation
The transportation of the device should meet the requirements of GB/T 4798.2. Among them, the transportation environment temperature is -25°C~70°C, and the relative humidity is <=85%.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 4208Degrees of protection provided by enclosures (IP code)
- GB/T 4798.2Classification of environmental conditions - Classification of groups of environmental parameters and their severities - Part 2: Transportation and handling
- GB/T 7251.1-2013Low-voltage switchgear and controlgear assemblies - Part 1: General rules
- GB/T 13384General specifications for packing of mechanical and electrical product
- GB/T 16935.1-2008Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
DL/T 478
Similar standards
How to Download NB/T 10204-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 634.5104-2009 — Telecontrol equipment and systems. part 5-104: Transmission protocols-Network access for IEC 60870-5-101 using standard transport profiles
GB/T 13384-2008 — General specifications for packing of mechanical and electrical product
GB/T 17626.8-2006 — Electromagnetic compatibility (EMC) -- Part 4-8: Testing and measurement techniques -- Power frequency magnetic field immunity test
Secure payment via Stripe
Payments accepted
NB/T 10204-2019
$150.00