Valid

GB/T 5824-2021Size system of opening for windows and doors in building (English PDF)

建筑门窗洞口尺寸系列

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 5824-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 9, 2021

Implementation date

October 1, 2021

Scope

GB/T 5824-2021 is the English-translated version of 建筑门窗洞口尺寸系列.

GB/T 5824-2021 sets the size system for window and door openings in building walls. It defines the coordinating width and height of an opening, the position lines that locate the frame in the opening, the structural reveal and the basic and auxiliary width and height parameters, built on the 3M and 6M modules.

It gives the opening sizes for doors and windows, the priority sizes for civil buildings and a six-digit model code taken from the coordinating width and height.

It explains how the reveal and the frame sizes follow from the installation form, the dry or wet installation method and the installation gap, and how designers should select sizes.

It applies to openings in exterior walls of industrial and civil buildings. It replaces GB/T 5824-2008, was issued on 9 March 2021 and has applied since 1 October 2021.

Found what you need?

Document preview — GB/T 5824-2021

National Standard of the People's Republic of China

ICS
91.060.50
Classification
Q 70
Replacing
GB/T 5824-2008

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Terms and definitions5
  • 4 Size system of opening for windows and doors in building10
  • 5 Determination for width and height of structural reveal AND width and height of windows and doors10
  • 6 Determination of width and height position lines of opening for windows and doors14
  • 7 Requirements for selection15

1 Scope

This Standard specifies the terms and definitions, size series and selection requirements for width and height of opening for windows and doors in building.

This Standard is applicable to the opening for windows and doors of various materials and exterior walls of industrial and civil buildings.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 5823, Terminology for building windows and doors

GB/T 50002, Standard for modular coordination of building

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in GB/T 5823 and GB/T 50002 as well as the followings apply.

3.1 Coordinating size between opening and frame of windows and doors (width and height)

It complies with the provisions for width, height mode number column of the opening for windows and doors. It is used to mark the vertical distance between the position lines in horizontal, vertical directions of the opening for windows and doors. It is the coordinating size BETWEEN the structural width and height of windows and doors AND the structural width and height of opening. It is called as coordinating width (B), coordinating height (A) of opening for windows and doors for short, in millimeters.

NOTE: The coordinating size between opening and frame of windows and doors is the nominal size of the opening of the building wall. It is the nominal size that determines the size of the opening and the size of the doors and windows.

3.2 Width and height position lines of opening for windows and doors

The position line of width, height coordinating size of opening for windows and doors, that is, the criterion to coordinate the position BETWEEN the doors and windows AND the opening (see Figure 1, Figure 2).

3.3 Width and height of structural reveal

The designed width and height of opening for windows and doors, that is, the net width (B1) and the net height (A1) of opening.

3.4 Width and height of windows and doors

The designed width and height of the doors and windows, that is, the width (B2), height (A2) of door and window profiles.

3.5 Size system of opening for windows and doors

A series of coordinating sizes that meet the width and high of the building door and window in line with the provisions for the number of building mold numbers AND the specified specifications of these coordinating sizes.

3.6 Basic width and height parameter of opening for windows and doors

The specified coordinating width and height, in line with horizontal, vertical expansion models 3M and 6M numbers that are respectively adopted by the width, height of opening for windows and doors.

3.7 Auxiliary width and height parameter of opening for windows and doors

In the horizontal, vertical expansion models 3M and 6M numbers that are respectively adopted by the width, height of opening for windows and doors, the specified coordinating width and height that are respectively inserted and less than the modulus level of this number column.

3.8 Coordinating basic specification of opening for windows and doors

The coordinating size specification of opening, of which the width, height of opening for windows and doors are basic parameters.

3.9 Coordinating auxiliary specification of opening for windows and doors

The coordinating size specification of opening, of which at least one of the width and height of opening for windows and doors is auxiliary parameter.

3.10 Elementary door

The single door that conforms to the basic specifications of size series of opening for doors.

4 Size system of opening for windows and doors in building

4.1 The size system of opening for doors in building shall meet the requirements of Table 1.

4.2 The size system of opening for windows in building shall meet the requirements of Table 2.

4.3 The priority size system of opening for doors in civilian building shall meet the requirements of Table 3.

4.4 The priority size system of opening for windows in civilian building shall meet the requirements of Table 4.

4.5 The coordinating width and height parameters of opening for non-rectangular windows and doors shall be selected according to the coordinating width and height parameters of opening for their external rectangle windows and doors [see Figure 1e)].

4.6 The specification model of the size system of opening for windows and doors in building is expressed by the six-digit number formed by the thousands, hundreds, and ten digits of coordinating width and height of opening for windows and doors, arranging in the before-and-after order. If there is no thousand digits, it is represented by "0".

Example 1: When the coordinating width of the opening for doors is 900mm and the coordinating height is 2100mm, its model shall be 090210.

Example 2: When the coordinating width of the opening for windows is 1200mm and the coordinating height is 1500mm, its model shall be 120150.

5 Determination for width and height of structural reveal AND width and height of windows and doors

5.1 The width and height of structural reveal AND width and height of windows and doors shall be respectively based on the width and height position lines of opening for windows and doors. They are determined according to installation form for doors and windows (flat connection, slot connection, overlapping), installation method (dry method, wet method) and structural gap for installing (see Figure 2).

7 Requirements for selection

7.1 Architectural design

7.1.1 The principle of coordination shall be implemented during architectural design.

The basic specifications of the size system for opening for windows and doors in this Standard shall prevail the auxiliary specifications. Reduce the number of specifications in the same area and the same building.

7.1.2 During the design of the standard layer of the living building, the size for opening for windows and doors shall be respectively selected from the priority sizes for opening for windows and doors in civilian building in Table 3, Table 4.

7.1.3 During the design of the standard layer of the public building, the size for opening for windows and doors shall be respectively selected from the priority sizes for opening for windows and doors in civilian building in Table 3, Table 4.

7.1.4 During industrial architecture design or non-standard layer design of civil building, if the specifications of this Standard cannot meet the needs, it can be determined in accordance with the column law for the size system for opening of basic specification, auxiliary specification for coordinating width, height of opening for windows and doors in this Standard.

7.1.5 When the architectural design adopts the design of the door and window product design, it shall be verified and confirmed that one of the installation forms, installation methods, and size of structural gap for installing. Make necessary supplementary design requirements.

7.1.6 When the architectural design needs to use a combination door and window, it is advisable to use the strip window, shape window and window door of the basic doors and windows.

7.2 Design of building doors and windows

7.2.1 When preparing the design documents for doors and windows, according to factors such as the materials, performance, quality standards for the doors and windows, select the size system of opening for windows and doors in this Standard. The relationship BETWEEN the width and height of windows and doors AND the position lines of opening for windows and doors, as well as the installation forms, methods of various types of walls that can be adapted and the size of structural gap for installing, shall be expressed. Propose corresponding technical measures.

7.2.2 It shall, according to the specifications of door and window frames or horizontal and vertical puppets as well as structural requirements, determine the width and height […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 5824

EditionTitleRevisionStatus
GB/T 5824-2021Size system of opening for windows and doors in buildingcurrent editionCurrent
GB/T 5824-2008Size system of opening for windows and doors in buildingprevious editionSuperseded

This page sells the current edition, GB/T 5824-2021. Earlier editions are listed for reference only.

How to Download GB/T 5824-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5824-2021

$225.00