GB/T 38264-2019Classification and test method of resistance against impact for curtain wall (English PDF)
建筑幕墙耐撞击性能分级及检测方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 38264-2019 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 10, 2019
Implementation date
November 1, 2020
Scope
GB/T 38264-2019 is the English-translated version of 建筑幕墙耐撞击性能分级及检测方法.
GB/T 38264-2019 is the Chinese standard "Classification and test method of resistance against impact for curtain wall". Its scope clause reads: This standard specifies the terms and definitions, classification, testing and inspection reports of resistance against impact for curtain wall.
This standard applies to the classification and testing of resistance against impact for curtain wall. Its clauses include terms and definitions; classification; testing; testing report.
It was issued by the State Administration for Market Regulation on DECEMBER 10, 2019 and took effect on NOVEMBER 01, 2020.
Found what you need?
Document preview — GB/T 38264-2019
National Standard of the People's Republic of China
- ICS
- 91.060.10
- Classification
- P 32
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 Terms and definitions5
- 4 Classification6
- 5 Testing7
- 6 Testing report13
1 Scope
This standard specifies the terms and definitions, classification, testing and inspection reports of resistance against impact for curtain wall.
This standard applies to the classification and testing of resistance against impact for curtain wall.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.
GB/T 2983-2015 Series of motorcycle tires
GB/T 34327 Terminology for curtain wall
3 Terms and definitions
The terms and definitions defined in GB/T 34327 as well as the following apply to this document. For ease of use, some terms and definitions in GB/T 34327 are repeatedly listed below.
3.1 Resistance against impact
The ability of curtain wall panels, components and their interconnections to resist the impact of soft or hard objects of the specified mass on the indoor or outdoor side without causing damage to human safety. [GB/T 34327-2017, definition 7.7]
3.2 Drop height
5 Testing
5.4.2 Selection of impact points for impact resistance to soft weights
5.4.2.1 General requirements
It may select the location as designated by the client for impact. When the impact resistance level needs to be assessed, the impact point shall be determined in accordance with the requirements of 5.4.2.2, 5.4.2.3, 5.4.2.4, 5.4.2.5.
5.4.2.2 Component glass curtain wall and unit glass curtain wall
For the component glass curtain wall and unit glass curtain wall, it shall determine the impact point according to the following requirements. The height of the impact point on the indoor side from the indoor completed surface shall not be more than 1.1 m:
a) The center of the curtain wall's fixed panel;
b) The center of the open panel;
c) The midpoint of the connection point between the adjacent upper and lower supports of the column;
d) The midpoint of the beam;
e) The point 100 mm above the connection point between the column and the beam (beam surface);
f) The point on the beam 100 mm away from the connection point.
5.4.2.3 Point-supported glass curtain wall
The point of impact of the point-supported glass curtain wall shall be the center of the curtain wall panel; meanwhile the height of the impact point on the indoor side from the indoor completed surface shall not be more than 1.1 m.
5.4.2.4 All-glass curtain wall
The impact point of the all-glass curtain wall shall be the center of the curtain wall panel; the height of the impact point on the indoor side from the indoor completed surface shall not be more than 1.1 m.
5.4.2.5
Stone curtain wall, metal plate curtain wall, artificial plate curtain wall The outdoor impact point of stone curtain wall, metal plate curtain wall and artificial plate curtain wall shall be the center of curtain wall panel.
5.4.3 Selection of impact points for impact resistance test of hard objects
It may select the location as designated by the client to make impact, which shall include the center point of the curtain wall panel.
5.4.4 Testing steps for impact resistance of soft weights and impact
resistance of hard objects The testing shall follow the steps below:
a) Suspend an impact object. The geometric center of the soft weight shall be within the circular range of the curtain wall facade with the impact point as the center of the circle and a radius of 50 mm. The geometric center of the hard weight shall be within the circular range of the curtain wall facade with the impact point as the center of the circle and a radius of 25 mm.
b) Lift the impact object so that its center reaches the specified drop height.
The drop height's error is ± 20 mm. The horizontal angle between the hanging wire rope and the horizontal plane of the suspension point should not be less than 14°. Keep the centerline of the impact object and the hanging wire rope centerline on the same straight line.
c) Release the impact object. Let it fall freely and hit the impact point once.
d) Tighten the impact object immediately after one impact, to avoid repeated impacts.
e) Observe and record the condition of the test piece.
5.5 Judgment of results
5.5.1 Impact resistance to soft weights
One of the following situations shall be judged as unqualified:
a) The panel comes off, is broken or cracked;
b) Decorative strips or other attachments have come off.
5.5.2 Impact resistance to hard object
Panel's failure, break or cracking shall be determined as unqualified.
6 Testing report
6.1 The testing report shall contain the following information:
a) Project name, project location, client name, contractor name;
b) Name and main dimensions of the test piece; […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 38264-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2983-2015 — Series of motorcycle tyres
GB/T 34327-2017 — Terminology for curtain walls
GB/T 7251.4-2026 — Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
Secure payment via Stripe
Payments accepted
GB/T 38264-2019
$165.00