GB/T 36115-2018Targeted poverty alleviation—Technical guide of village photovoltaic power station (English PDF)
精准扶贫 村级光伏电站技术导则
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36115-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 15, 2018
Implementation date
October 1, 2018
Scope
GB/T 36115-2018 is the English-translated version of 精准扶贫 村级光伏电站技术导则.
GB/T 36115-2018 is a technical guide for the village photovoltaic power stations built under China's targeted poverty alleviation programme. It covers the design, construction and installation, commissioning and acceptance, and operation and maintenance of village-level stations, and applies to stations of 500 kW or below built in poor villages.
Terms such as photovoltaic module and photovoltaic array are taken from GB 50797-2012.
The guide works through the national rules for photovoltaic plants, among them GB 50797 on design, GB 50794 on construction, GB/T 50796 on acceptance, GB/T 29319 on connection to the distribution network, GB/T 32512 on lightning protection, GB/T 35694 on safety and GB 51101 on bracket foundations, with DL/T 448 for metering. It was issued on 15 March 2018 and has applied since 1 October 2018.
Found what you need?
Document preview — GB/T 36115-2018
National Standard of the People's Republic of China
- ICS
- 27.160
- Classification
- F 12
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Power Station Design
- 5 Construction Installation
- 6 Commissioning and acceptance
- 7 Operation and maintenance
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the requirements for the design, construction and installation, commissioning and acceptance, and operation and maintenance of village-level photovoltaic power stations.
This standard is applicable to photovoltaic power plants of 500kW or below that are under construction in a poor village.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest version (including all amendments) applies to this document.
GB 2894 Safety Signs and Guidelines for Use
GB/T 9535 Surface Crystalline Silicon Photovoltaic Module Design Identification and Stereotype
GB/T 29319 Photovoltaic Power Generation System Access Distribution Network Technical Regulations
GB/T 32512 Photovoltaic Power Station Lightning Protection Technical Requirements
GB/T 34936 Photovoltaic Power Station Conveyor Box Technical Requirements
GB/T 35694 Photovoltaic Power Station Safety Regulations
GB 50217 Power Engineering Cable Design Specification
GB 50794 photovoltaic power station construction specification
GB/T 50796 Photovoltaic Power Project Acceptance Specifications
GB 50797 photovoltaic power station design specifications
GB/T 50865 Photovoltaic Generation Access Distribution Network Design Specification
GB 51101 Solar Power Station Bracket Foundation Technical Specifications
DL/T 448 Electrical Metering Device Technical Management Procedures
DL/T 5137 Technical Specification for Electrical Measurement and Energy Metering Device Design
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Photovoltaic module
With a package and internal connection, can be independently provided a direct current output, the smallest integral solar cell combination device. Sun The solar assembly. [GB 50797-2012, Definition 2.1.1]
3.2 Photovoltaic arrays
A plurality of photovoltaic modules are assembled mechanically and electrically in a certain manner and have a fixed supporting structure and constitute a direct-current hair Electric units, also known as photovoltaic arrays. [GB 50797-2012, definition 2.1.4]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 2894Safety colours and safety signs
- GB/T 9535Crystalline silicon terrestrial photovoltaic(PV) modules-design qualification and type approval
- GB/T 29319Technical requirements for connecting photovoltaic power system to distribution network
- GB/T 32512Technical requirements for protection of photovoltaic power station against lightning
- GB/T 34936Technical requirement of combiner box for photovoltaic power station
- GB/T 35694Safety code for photovoltaic power stations
Cited by
- GB/Z 38766-2020Targeted poverty alleviation - Specification for operation and management of photovoltaic-agriculture project
- GB/T 36117-2018Guide for the planning and design of the rural photovoltaic power station cluster connected to power grid
- GB/T 36119-2018Targeted poverty alleviation—Management and evaluation guide of village photovoltaic power station
Similar standards
How to Download GB/T 36115-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.