GB 47739-2026Safety requirements for photovoltaic modules (English PDF)

光伏组件安全要求

Open the GB 47739-2026 preview as PDF

Preview — first pages of GB 47739-2026 (full document: 37 pages)

This is a limited preview

Buy now to download the full PDF (37 pages)

Issued by

SAMR; SAC

Level / Type

National · Mandatory

Issue date

May 25, 2026

Implementation date

June 1, 2027

Scope

GB 47739-2026 is the English-translated version of 光伏组件安全要求.

GB 47739-2026 is the Chinese national standard covering the safety of a PV module - the electrical insulation and creepage at system voltage, the fire behaviour, the mechanical load and impact, the hot spot endurance, the junction box and connectors, and the marking that tells an installer what they are handling. A mandatory standard, and a first edition: China makes most of the world's modules, and this makes safety a condition of sale rather than a certification option. In force from 1 June 2027. It was issued on 25 May 2026 and takes effect on 1 June 2027, as a first edition. The document is under the responsibility of the Ministry of Industry and Information Technology. This page is published from the official record of the 2026 edition; the clause text of a standard this recent is not yet in circulation, and the figures, limits and tables it contains are those of the document itself, delivered in full with the English translation.

Document preview — GB 47739-2026

National Standard of the People's Republic of China

ICS
27.160
Classification
K 83

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 5.1 Electrical Safety
  • 5.1.1 General Requirements
  • 5.1.3 Electrical components
  • 5.2 Fire Safety
  • 5.2.1 General Requirements
  • 5.3 Mechanical Safety
  • 5.3.1 General Requirements
  • 5.4 Restrictions on Hazardous Substances
  • 6 Test Methods
  • 6.1 Test Classification
  • 6.3 Electrical safety test
5.1.1 General Requirements

5.1.1.1 Photovoltaic modules should have sufficient insulation protection measures. Dangerous live parts should not be directly exposed and should be tested through accessible means. Verification (see 6.3.4).

5.1.1.2 Photovoltaic modules should maintain the insulation performance required for safe operation in humid environments and should pass a wet leakage current test (see 6.3.3). For surface-mounted photovoltaic modules... For photovoltaic modules with an area not exceeding

0.1 m^2, the insulation resistance should be not less than 400 MOmega; for photovoltaic modules with an area greater than

0.1 m^2, the measured insulation resistance should be... The insulation resistance multiplied by the area of the photovoltaic module should be no less than 40 MOmega·m2.

5.1.1.3 Photovoltaic modules using polymer materials as front or back sheets should still provide sufficient electrical conductivity under mechanical contact or cutting stress. Protective measures should be taken to avoid the risk of electric shock. It should pass a scratch resistance test (see 6.3.5).

5.1.1.4 Photovoltaic modules shall be able to withstand overvoltage caused by switching of low-voltage equipment and shall pass a pulse voltage test (see 6.3.8).

5.1.1.5 The electrical clearances and creepage distances of photovoltaic modules shall comply with the requirements of Appendix A.

5.1.2 Insulation Protection Based on the requirements of GB/T 17045-2020, photovoltaic module insulation protection is divided into Class II, Class 0, and Class III, with corresponding levels of protection provided in designated areas. The photovoltaic modules used should meet the insulation protection requirements in Table 1.

5.1.3 Electrical components

5.1.3.1 Components providing thin-layer insulation in photovoltaic modules shall have sufficient insulation thickness to meet the requirements of A.3.1, and shall be certified by insulation thickness. Experiment (see 6.3.1).

5.1.3.2 The internal wiring of photovoltaic modules should have a sufficiently large current-carrying capacity to meet the relevant functions and should comply with GB/T 20047.1-2025. The requirements of section 6.3.2.

5.1.3.3 External wires and cables of photovoltaic modules shall have the ability to maintain electrical protection under environmental stress and shall comply with GB/T 20047.1- Requirements of

5.1.3.4 The lead cables of photovoltaic modules should be able to withstand mechanical loads such as tension and torque during installation and use, and should not detach or be damaged. If there is a fault or electrical malfunction, a lead end strength test should be performed (see 6.3.7).

5.1.3.5 The external DC connectors for photovoltaic modules shall comply with the requirements of

6.3.5 in GB/T 20047.1-2025, and the junction boxes shall comply with... The requirements of

6.3.6 in GB/T 20047.1-2025.

5.1.3.6 The front and back panels of photovoltaic modules shall comply with the requirements of

6.3.7 in GB/T 20047.1-2025.

5.1.3.7 The insulation barrier of photovoltaic modules shall meet the requirements of

6.3.8 in GB/T 20047.1-2025.

5.1.3.8 The electrical connection of photovoltaic modules shall comply with the requirements of

6.3.9 in GB/T 20047.1-2025.

5.1.3.9 The bypass diodes of photovoltaic modules shall comply with the requirements of

5.2.1 General Requirements

5.2.1.1 Photovoltaic modules should be able to withstand hot spots, and the hot spots generated during operation in various application scenarios should not cause a fire hazard to the photovoltaic modules. Risk. It should pass the hot spot durability test (see 6.4.1).

5.2.1.2 When the bypass diode of a photovoltaic module is operating, its junction temperature should not exceed the maximum rated junction temperature specified by the manufacturer. This should be achieved through the bypass diode. Tube thermal test (see 6.4.2) and bypass diode functional test (see 6.4.3).

5.2.1.3 Photovoltaic modules should not overheat, catch fire, or suffer permanent damage under reverse current conditions. They should pass a reverse current overload test (see...). (6.4.4) The maximum temperature on the outer surface of the photovoltaic module during the test should not exceed 170 °C.

5.2.1.4 The external polymer components of photovoltaic modules should be capable of resisting external fire sources and preventing the spread of flames. The flammability rating of materials used in composite components (excluding junction boxes, connectors, cables, and thin-layer insulation components) shall not be lower than that specified in GB/T 5169.16. Level V-1.

5.2.2 Fire Safety of Building Photovoltaic Modules Photovoltaic modules used in buildings should meet at least the B1 rating requirements specified in section

5.3.2 of GB 8624-2025 for their combustion performance, and should... Pass the flammability rating test (see 6.4.7).

5.3.1 General Requirements

5.3.1.1 Photovoltaic modules shall be free of any inaccessible burrs, sharp edges, or pointed corners that could cause harm. This shall be verified through visual inspection (see 6.2) and... Sharp edge test (see 6.5.1).

5.3.2 Static Mechanical Load Photovoltaic modules should be able to withstand static loads. Photovoltaic modules with rigid planar structures and rigid frames should be mounted on fixed supports. For installation methods, the front-side design load should be no less than 2400 Pa, and the rear-side design load should be no less than 1600 Pa. Other types of photovoltaic modules adopt... For fixed bracket installation, the design load on the front and back of the photovoltaic modules should not be less than 1600 Pa. Tracking brackets and flexible photovoltaic systems can also be used. The design load of photovoltaic modules installed using brackets, special clamps, or other mounting methods should ensure the mechanical structural safety of the photovoltaic modules during use. This should be verified through... Static mechanical load test (see 6.5.2).

5.3.3 Dynamic Mechanical Load Photovoltaic modules should be able to withstand dynamic loads. They should pass a dynamic mechanical load test (see 6.5.3).

5.3.4 Damage Protection If a photovoltaic module is damaged by impact under the specified installation method, the middle layer of the photovoltaic module should not break, and the photovoltaic module should not break due to surface fragmentation. The internal circuitry is exposed by peeling off the wafers. The module must pass a component breakage test (see 6.5.4). Class 0 photovoltaic modules are exempt from the component breakage test.

5.3.5 Hail Resistance Photovoltaic modules should be resistant to hail impact and should not break after a specified hail test. They should pass the hail test (see 6.5.5).

5.4 Restrictions on Hazardous Substances

5.4.1 Photovoltaic modules shall not leak harmful substances that cause environmental pollution or harm to human health.

5.4.2 The arsenic content (calculated as arsenic trioxide) in the glass components of photovoltaic modules should not exceed 0.005% (50 ppm). It should pass through a hazardous substance testing process. (Arsenic) detection (see 6.6).

6.3 Electrical safety test

6.3.1 Insulation Thickness Test The test shall be conducted according to section

10.5 of GB/T 20047.2-2025, and the measured insulation thickness shall be greater than that corresponding to the photovoltaic standard in Table A.1 or Table A.2. Requirements for component insulation protection category.

6.3.2 Insulation Test The test shall be conducted in accordance with section

10.13 of GB/T 20047.2-2025.

6.3.3 Wet leakage current test The test shall be conducted in accordance with section

10.14 of GB/T 20047.2-2025.

6.3.4 Contact Test The test shall be conducted in accordance with section

10.9 of GB/T 20047.2-2025.

6.3.5 Scratch resistance test The test shall be conducted in accordance with section

10.10 of GB/T 20047.2-2025.

6.3.6 Continuity test of equipotential bonding The test shall be conducted in accordance with section

10.11 of GB/T 20047.2-2025.

6.3.7 Lead end strength test The test shall be conducted in accordance with section

4.14 of GB/T 9535.2-2025, and the test shall be modified as follows: the section in GB/T 9535.2-2025 shall be deleted.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 37 pages — is available in the English PDF.

How to Buy GB 47739-2026

  1. 1Add to cart. Click the "Buy GB 47739-2026" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
37 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 47739-2026

$365.00

$310.00for partners