GB 47740-2026 is the Chinese national standard covering what must be on the nameplate of a PV module - the electrical ratings at standard test conditions, the system voltage and fuse rating, the class and the safety markings, the manufacturer and the traceable serial number. The nameplate is what an installer sizes a string from and what an inspector checks against. Mandatory, first edition, in force from 1 June 2027, with the module safety standard GB 47739-2026. It was issued on 25 May 2026 and takes effect on 1 June 2027, as a first edition. The document is under the responsibility of the Ministry of Industry and Information Technology. This page is published from the official record of the 2026 edition; the clause text of a standard this recent is not yet in circulation, and the figures, limits and tables it contains are those of the document itself, delivered in full with the English translation.
Document preview — GB 47740-2026
National Standard of the People's Republic of China
- ICS
- 27.160
- Classification
- K 83
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 4 General Requirements
- 5 Labeling Requirements
- 5.3 Electrical performance parameters
- 5.3.1 General Requirements
- 5.3.2 Nominal Power
- 5.3.3 Nominal open-circuit voltage
- 5.3.4 Nominal short-circuit current
- 5.3.5 Maximum power point voltage
- 5.3.6 Maximum power point current
- 5.3.7 Nominal power on both sides
- 5.3.8 Bilateral Open Circuit Voltage
- 5.3.9 Bilateral Short-Circuit Current
Foreword
This document conforms to GB/T 1.1-2020 "Standardization Work Guidelines Part
1.Structure and Drafting Rules of Standardization Documents". Drafting is scheduled. Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents. This document was proposed and is under the jurisdiction of the Ministry of Industry and Information Technology of the People's Republic of China. Photovoltaic module nameplate marking requirements
1.Scope This document specifies the general requirements and marking requirements for nameplates of ground-mounted photovoltaic modules. This document applies to nameplate labeling of crystalline silicon photovoltaic modules and thin-film photovoltaic modules intended for long-term outdoor use. Other types of photovoltaic modules... For reference use of the Volt component. This document does not apply to space-based photovoltaic modules and concentrated photovoltaic modules.
4 General Requirements
4.1 The content of the nameplate markings should be complete, objective, and accurate.
4.2 Nameplate markings and descriptions shall use standard Chinese characters officially promulgated and implemented by the state, and may also use Hanyu Pinyin, minority languages, or foreign languages. Text. When using, the Chinese text shall prevail.
4.3 The nameplate should be clear and easy to identify and read, and should remain unblurred and identifiable throughout the expected lifespan of the photovoltaic module.
4.4 The nameplate shall be solvent resistant and abrasion resistant, and the text shall be indelible. It shall meet the requirements of
10.6 in GB/T 20047.2-2025.
4.5 Nameplate installation should use adhesives or mechanical fixing methods that are resistant to high temperature and humidity and ultraviolet radiation to ensure the expected service life of the photovoltaic modules. It is firmly secured and will not fall off.
4.6 The nameplate should be placed in a location that is easily visible and legible, and should not affect the normal use, transportation, installation and maintenance of the product.
4.7 The nameplate should include a QR code. The QR code should link to the component's nameplate information (see 5.1) and its temperature coefficient and bifaciality coefficient (suitable for use with other components). (Time required), installation manual, etc. If the barcode identifies the production address and production date, the QR code information should include the barcode and the production address and date. The correspondence between production dates. The QR code link should be accessible normally within the expected lifespan of the photovoltaic modules.
4.8 For components used in specific scenarios (such as building-integrated photovoltaic modules, offshore photovoltaic modules, etc.), the content of the nameplate markings should conform to the specific requirements. Application scenario requirements, such as the requirement that building photovoltaic modules should be labeled with fire resistance ratings, etc.
5 Labeling Requirements
5.1 General Rules The nameplate should include the photovoltaic module's model, name, trademark, manufacturer's name, manufacturer's address, electrical performance parameters, dimensions, and weight. Maximum system voltage, maximum rated overcurrent, electrical protection category, and electric shock protection markings. See Appendix A for an example of nameplate markings.
5.2 Product Name Product names should be clear and unambiguous.
5.3.1 General Requirements
5.3.1.1 Electrical performance parameters include nominal power, nominal short-circuit current, nominal open-circuit voltage, nominal maximum power point current, and nominal maximum power. Point voltage. The electrical performance parameters of bifacial modules should include nominal bifacial power, nominal bifacial open-circuit voltage, and nominal bifacial short-circuit current.
5.3.1.2 The measurement methods for electrical performance parameters shall comply with GB/T 6495.1-2025 or other equivalent methods. Test equipment and procedures are detailed in [link to test procedures]. Appendix B.
5.3.1.3 The measurement results of electrical performance parameters shall be traceable to the national metrological standard in accordance with the requirements of IEC 60904-4.(Level 1 standard photovoltaic module quantity) Value traceability requirements refer to JJF 2061.
5.3.1.4 The original data of electrical performance parameter measurements should be verifiable and cannot be altered or replaced. Records should be retained for at least the time specified for the photovoltaic module. Expected service life of the component.
5.3.2 Nominal Power
5.3.2.1 The nominal power Pmax (NP) is in watts (W). The nominal power tolerance should be indicated.
5.3.2.2 Before leaving the factory, the components shall undergo I-V characteristic testing under standard test conditions, and the measured maximum power value Pmax (Meas) shall be compared with the nominal power. The deviation of Pmax (NP) should not exceed the smaller of the upper and lower limits of the tolerance or ±2%, as shown in formula (1) or formula (2). For thin films and perovskites... For mining photovoltaic modules, the deviation should not exceed ±5%, see formula (3).
5.3.3 Nominal open-circuit voltage
5.3.3.1 The nominal open-circuit voltage VOC (NP) is in volts (V). The open-circuit voltage tolerance should be specified.
5.3.3.2 Before leaving the factory, the components should undergo I-V characteristic testing at STC. The deviation between the nominal value and the test result should not exceed ±3%. For thin... For film and perovskite photovoltaic modules, the deviation should not exceed ±5%.
5.3.4 Nominal short-circuit current
5.3.4.1 The nominal short-circuit current ISC (NP) is in amperes (A). Short-circuit current tolerances should be specified.
5.3.4.2 Before leaving the factory, the components shall undergo I-V characteristic testing at STC, and the deviation between the nominal value and the test result shall not exceed ±5%.
5.3.4.3 The verification of the nominal short-circuit current ISC(NP) of the component shall conform to the verification formula (6).
5.3.5 Maximum power point voltage
5.3.5.1 Maximum power point voltage Vmpp (NP) is in volts (V).
5.3.5.2 I-V characteristic testing should be performed at STC before the components leave the factory.
5.3.6 Maximum power point current
5.3.6.1 The nominal short-circuit current Impp (NP) is measured in amperes (A).
5.3.6.2 I-V characteristic testing should be performed at STC before the components leave the factory.
5.3.7 Nominal power on both sides
5.3.7.1 Bifacial Nominal Power Pmax (BNPI) is the Bifacial Nameplate Irradiance (BNPI) test. The maximum power under the specified conditions, in watts (W). The nominal power tolerance should be indicated on both sides.
5.3.7.2 The deviation between the nominal power of the two sides and the maximum power under BNPI conditions obtained according to the method of IEC TS 60904-1-2 should not exceed [the specified value]. Exceeding ±3%. For thin-film and perovskite photovoltaic modules, the deviation should not exceed ±5%.
5.3.8 Bilateral Open Circuit Voltage
5.3.8.1 The double-sided open-circuit voltage VOC (BNPI) is the open-circuit voltage corresponding to the BNPI test conditions, in volts (V). It should be marked as double-sided. Open-circuit voltage tolerance.
5.3.8.2 The deviation between the double-sided open-circuit voltage and the open-circuit voltage under BNPI conditions obtained according to the method of IEC TS 60904-1-2 should not exceed [the specified value]. Exceeding ±5%.
5.3.9 Bilateral Short-Circuit Current
5.3.9.1 The bi-directional short-circuit current ISC (BNPI) is the short-circuit current corresponding to the BNPI test conditions, in amperes (A). Bi-directional should be indicated. Short-circuit current tolerance.
5.3.9.2 The deviation between the bi-directional short-circuit current and the short-circuit current under BNPI conditions tested according to IEC TS 60904-1-2 should not exceed [the specified value]. Exceeding ±5%.
5.4 Dimensions The nameplate should indicate the external dimensions of the photovoltaic module, including length, width, and height. The units for length, width, and height are all millimeters (mm).
5.5 Weight The nameplate should indicate the weight of the photovoltaic module in kilograms (kg).
5.6 Maximum System Voltage The nameplate should indicate the maximum system voltage in volts (V).
5.7 Maximum Rated Overcurrent The nameplate should indicate the maximum rated overcurrent in amperes (A). The maximum rated overcurrent shall be verified in accordance with
10.20 of GB/T 20047.2-2025.The rated value In shall not be less than
1.4 times the ISC. And less than
2.5 times that of ISC. For bifacial photovoltaic modules, the rated value In should be no less than
1.4 times that of ISC-aBSI and less than
2.5 times that of ISC-aBSI.
5.8 Electrical protection category markings and electric shock protection markings Nameplates should use the corresponding electrical protection category markings and electric shock protection markings as per Table 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
How to Buy GB 47740-2026
- 1Add to cart. Click the "Buy GB 47740-2026" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 47740-2026
$230.00