GB/T 19409-2013water-source (ground-source) heat pumps (English PDF)

水(地)源热泵机组

Preview PDF

This is a limited preview

Buy now to download the full PDF (28 pages)

Need quotation for your management?

Get a formal quotation for GB/T 19409-2013 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 17, 2013

Implementation date

October 1, 2014

Scope

GB/T 19409-2013 is the English-translated version of 水(地)源热泵机组.

GB/T 19409-2013 is the Chinese standard "Water-source (ground-source) heat pumps".

Its scope clause reads: This standard specifies the terms and definitions, types and basic parameters, requirements, test methods, inspection rules, marking, packaging, transport and storage of water source (ground-source) heat pumps (hereinafter referred to as "UNIT").

This standard applies to water source heat pumps that use electromechanical compression cooling system and takes the water circulating in buried pipes or water in wells, lakes, rivers, oceans, sewage, industrial waste, or water in common pipelines as cold (hot) source.

Its clauses include terms and definitions; types and basic parameters; requirements; test method; inspection rules; mark, packaging, transportation and storage.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on DECEMBER 17, 2013 and took effect on OCTOBER 01, 2014.

Found what you need?

Document preview — GB/T 19409-2013

National Standard of the People's Republic of China

ICS
27.200
Classification
J 73
Replacing
GB/T 19409-2003

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Terms and definitions6
  • 4 Types and basic parameters7
  • 5 Requirements9
  • 6 Test method13
  • 7 Inspection rules20
  • 8 Mark, packaging, transportation and storage21
  • Annex A24
  • Annex B28

Foreword

This standard is drafted according to rules given by GB/T 1.1-2009.

This standard replaces GB/T 19049-2003 Water-source heat pumps. The main technical changes are as follows, compared with GB/T 19049-2003.

- Add the "surface water type" in type;

- Change the name of underground loop type into "buried pipe type";

- Change the "inlet-outlet water temperature difference 5°C at heat-source side under working condition of hot-cold water models" to "the combination of outlet water temperature and water flow";

- Change the heat pump from 8-gears to 2-gears, according to cold classification;

- Modify the working condition; the working condition of centrifugal units and volumetric units are determined separately;

- Add the annual coefficient of performance (ACOP) as the energy efficiency index of heat pump unit.

1 Scope

This standard specifies the terms and definitions, types and basic parameters, requirements, test methods, inspection rules, marking, packaging, transport and storage of water source (ground-source) heat pumps (hereinafter referred to as "UNIT").

This standard applies to water source heat pumps that use electromechanical compression cooling system and takes the water circulating in buried pipes or water in wells, lakes, rivers, oceans, sewage, industrial waste, or water in common pipelines as cold (hot) source.

2 Normative references

The following documents are indispensable for application of this document. For the dated documents so quoted, only dated versions apply to this document. For the undated documents so quoted, the latest versions (including all modification sheets) apply to this document.

GB/T 191 Packaging - Pictorial marking for handling of goods

GB/T 3785-1983 Electric, sonic properties and measuring methods for sound level meters

GB 4706.32 Safety of household and similar electrical appliances - Particular requirements for heat pumps, air-conditioner and dehumidifier

GB/T 5226.1 Electrical equipment of industrial machines. Part 1: General requirements

GB/T 6388 Transport package shipping mark

GB/T 10870-2001 The methods of performance test for positive displacement and centrifugal water-chilling units and heat pump

GB/T 13306 Plates

GB/T 18430.1-2007 Water chilling (heat pump) packages using the vapor compression cycle - Household and similar water chilling (heat pump) packages

GB/T 17758-2010 Unitary air conditioners

GB/T 18836-2002 Ducted air-conditioning (heat pump) units

3 Terms and definitions

3.1.5 Ground-loop heat pumps

The UNIT that uses water circulating in underground coil as cold (hot) source.

3.1.6 Surface-water heat pump

The UNIT that uses water in lakes, rivers, oceans, sewage, industrial waste, or other surface water as cold (hot) source.

3.2 (ACOP) Annual Coefficient of Performance; ACOP

The annual coefficient of performance obtained by comprehensively WEIGHTING the efficiency for water-source (ground-source) heat pumps when operating at full-load under nominal cooling conditions and nominal heating conditions WITH several office buildings in typical cities according to the ratio of cooling and heating time. Annual coefficient of performance ACOP = 0.56EER+0.44COP

Note 1.EER is the energy efficiency of water (ground) heat pump when the UNIT runs at full capacity under rated cooling condition.

Note 2.COP the energy efficiency of water (ground) heat pump when the UNIT runs at full capacity under rated heating condition.

Note 3. The weighting coefficients, 0.56 and 0.44, are the proportion of cooling and heating time of office buildings in Beijing, Harbin, Wuhan, Nanjing and Guangzhou that accounts for the total air-conditioned time of office buildings.

4 Types and basic parameters

4.1 The types of water-to-air heat pump [Translator. hereafter abbreviated as "heat-pump"]

4.1.1 The UNITs are divided into the following according to functions;

a) Heat-pump type;

b) Single-cold type; c) Single-hot type.

4.1.2 The UNITs are divided into the following according to structure types;

a) Monolithic type; b) Separated type.

4.1.3 The UNITs are divided into the following according to fan supply types;

a) Direct blowing type;

b) Compressed air type.

4.1.4 The UNITs are divided into the following according to the type of cold (hot) source types;

a) Water-loop type;

b) Ground-water type;

c) Ground-loop type; d) Surface-water type.

4.2 The types of water-to-water heat-pump

4.2.1 The UNITs are divided into the following according to function;

a) Heat-pump type;

b) Single-cold type; c) Single-hot type.

4.2.2 The UNITs are divided into the following according to structure types;

a) Integral type; b) Separated type.

4.2.3 The UNITs are divided into the following according to the type of cold (hot) source types;

a) Water-loop type;

b) Ground-water type;

c) Ground-loop type; d) Surface-water type.

4.3 Basic parameters

5 Requirements

5.2.5 The water quality of the UNIT heat-source shall comply with requirements in Annex D of GB/T 18430.1-2007. The water that cannot meet the quality requirements shall be treated specially, or the appropriate heat exchanging equipment shall be used.

5.3 Performance requirements

5.3.1 Sealing of cooling system

There shall be no leakage of refrigerant in all parts of cooling system of the UNIT.

5.3.2 Running

The running test shall be done for the UNIT before the UNIT leaves the factory; there shall be no abnormal situation of the UNIT after test. If the test condition is not complete or the UNIT has a rated voltage being more than 3000 V, the UNIT can be run on-site.

5.3.3 Cooling capacity

The actual measured cooling capacity of the UNIT shall not be less than 95% of the nominal cooling capacity.

5.3.4 Power of cooling system

The actual measured power of cooling system shall not be larger than 110% of the nominal power of cooling system.

5.3.5 Heat capacity

of heat-pump The actual measured heat capacity of heat-pump shall not less than 95% of the nominal heat capacity of heat-pump.

5.3.6 Heating power consumption of heat-pump

The actual measured heating power consumption of heat-pump shall not be larger than 110% of the nominal heating power consumption of heat-pump.

5.3.7 Static pressure and air flow

5.3.7.1 The actual measured minimum external static pressure of outdoor UNIT of air pipe shall not be less than 95% of nominal statistic pressure value.

5.3.7.2 The actual measured air flow of water-to-air heat-pump shall not be less than 95% of nominal air flow. […]

5.3.8 The maximum operating cooling

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 28 pages — is available in the English PDF.

Referenced standards

Cited by

Similar standards

Editions of GB/T 19409

EditionTitleRevisionStatus
GB/T 19409-2013water-source (ground-source) heat pumpscurrent editionCurrent
GB/T 19409-2003water-source (ground-source) heat pumpsprevious editionSuperseded

This page sells the current edition, GB/T 19409-2013. Earlier editions are listed for reference only.

How to Download GB/T 19409-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
28 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19409-2013

$105.00