GB/T 13081-2022Determination of mercury in feeds (English PDF)
饲料中汞的测定
Open the GB/T 13081-2022 preview as PDF
This is a limited preview
Buy now to download the full PDF (17 pages)
Issued by
State Administration for Market Regulation; Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 30, 2022
Implementation date
July 1, 2023
Scope
GB/T 13081-2022 is the English-translated version of 饲料中汞的测定.
GB/T 13081-2022 is the Chinese national standard on determination of mercury in feeds, in the field of agriculture. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 30 December 2022 by the State Administration for Market Regulation; Standardization Administration of China, and has been in force since 1 July 2023. Classification: ICS 65.120, CCS B46. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB/T 13081-2022
National Standard of the People's Republic of China
- ICS
- 65.120
- Classification
- B46
Issued by: State Administration for Market Regulation; Standardization Administration of China
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Atomic fluorescence spectrometry (arbitration method)
- 4.3 Instruments and equipment
- 4.5 Test procedures
- 4.5.1 Sample solution preparation
- 5 Cold atomic absorption spectrometry
- 5.3 Instruments and equipment
- 5.5 Test procedures
- 6 Direct injection method
- 6.3 Instruments and equipment
- 6.5 Test procedures
- 6.5.1 Standard curve drawing Accurately pipette
- 6.5.2 Determination Weigh
Foreword
This document was drafted in accordance with the provisions of GB/T 1.1-2020 Directives for standardization - Part
1.Rules for the structure and drafting of standardizing documents. This document replaces GB/T 13081-2006 Determination of mercury in feeds. Compared with GB/T 13081-2006, in addition to structural adjustments and editorial changes, the main technical changes are as follows:
a) The scope of application has been increased to concentrate supplements and feed ingredients; the quantitation limits of atomic fluorescence spectrometry and cold atomic absorption spectrometry are added (see Chapter 1; see Chapter 1 of the 2006 edition);
b) The treatment methods of high-pressure tank digestion and microwave digestion are changed (see
4.5.1.1 and 4.5.1.2; see
4.4.1.2 of the 2006 edition);
c) The reference conditions of microwave digestion are changed (see 4.5.1.2; see
4.4.1.2 of the 2006 edition);
d) The reference conditions of the atomic fluorescence spectrometry instrument are changed (see 4.5.2; see
4.4.3 of the 2006 edition);
e) The test data processing is changed (see
4.6 and 5.6; see
5.5 of the 2006 version);
f) The expression of precision is changed (see
1 Scope
GB/T 13081-2022 is the Chinese national standard on determination of mercury in feeds, in the field of agriculture. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 30 December 2022 by the State Administration for Market Regulation; Standardization Administration of China, and has been in force since 1 July 2023. Classification: ICS 65.120, CCS B46. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This document describes the atomic fluorescence spectrometry, cold atomic absorption spectrometry, and direct injection methods for the determination of total mercury in feeds. This document is applicable to the determination of total mercury in compound feeds, concentrated feeds, concentrate supplements, additive premixed feeds, feed raw materials, and feed additives. Atomic fluorescence spectrometry. When the sample weight is
0.5 g and the constant volume is 50 mL, the method detection limit is 0.6 µg/kg and the quantification limit is 3 µg/kg. Cold atomic absorption spectrometry. When the sample weight is 2 g and the constant volume is 100 mL, the method detection limit is 3 µg/kg and the quantitation limit is 10 µg/kg. Direct injection method. When the sample weighing amount is
0.1 g, the detection limit of the method is 0.3 µg/kg, and the quantification limit is 1 µg/kg.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. For the dated referenced documents, only the versions with the indicated dates are applicable to this document; for the undated referenced documents, only the latest version (including all the amendments) is applicable to this document.
GB/T 6682 Water for analytical laboratory use - Specification and test methods
GB/T 20195 Animal feeding stuffs - Preparation of test samples
3 Terms and definitions
There are no terms or definitions that need to be defined in this document.
4 Atomic fluorescence spectrometry (arbitration method)
4.1 Principle After the sample is digested by acid heating, mercury is reduced to atomic mercury by potassium borohydride (KBH4) in the acidic medium, which is brought into the atomizer by argon gas. Under the irradiation of a special mercury hollow cathode lamp, the ground-state mercury atoms are excited to a high energy state and then deactivated back to the ground state, which emit fluorescence with a characteristic wavelength. Its fluorescence intensity is proportional to the mercury content and can be quantified by the external standard method.
4.2 Reagents or materials WARNING -- Mercury is highly toxic. Pay attention to ventilation when handling and avoid contact with skin and clothing. All kinds of strong acids shall be handled carefully and shall be handled in a fume hood.
4.3 Instruments and equipment
4.3.1 Atomic fluorescence spectrometer. It is equipped with a mercury hollow cathode lamp.
4.3.2 Analytical balance. The sensitivity is 0.0001 g.
4.3.3 High-pressure digestion tank. It is equipped with a 100 mL polytetrafluoroethylene digestion tube.
4.3.4 Microwave digestion instrument. It is equipped with a 50 mL polytetrafluoroethylene digestion tube.
4.3.5 Constant temperature drying oven. The temperature control accuracy is ±2 °C.
4.3.6 Ultrasonic cleaner. NOTE. Glassware and polytetrafluoroethylene digestion tubes need to be soaked in nitric acid solution I (4.2.4) for 24 hours, and then rinsed repeatedly with water.
4.4 Samples The sample is prepared according to GB/T 20195.The solid sample shall be at least 200 g. It is crushed so that it all passes through an analysis sieve with a pore size of
0.425 mm; it is mixed thoroughly and stored in an airtight container for later use.
4.5.1 Sample solution preparation
4.5.3 Determination Adjust the atomic fluorescence spectrometer to the best working condition and start measurement after stabilizing for 10 to 20 minutes. Use nitric acid solution III (4.2.6) as the carrier fluid and potassium borohydride solution (4.2.8) as the reducing agent, and use nitric acid solution II (4.2.5) to continuously inject samples; after the reading is stable, measure the standard series of solutions.
4.6 Test data processing The mercury content w in the sample is expressed as a mass fraction, in milligrams per kilogram (mg/kg), and is calculated according to formula (1).
4.7 Precision Under repeatability conditions, the ratio of the absolute difference between the two independent measurement results and their arithmetic mean to the arithmetic mean, that is, the relative deviation r, shall meet the requirements of Table 3.
5 Cold atomic absorption spectrometry
5.1 Principle The sample is digested with nitric acid-sulfuric acid, and the mercury is converted into an ionic state. Under strong acid conditions, mercury ions are reduced to elemental mercury by stannous chloride, which is blown out by dry clean air. The absorbance is measured at a wavelength of 253.7 nm and quantified by the external standard method.
5.2 Reagents or materials WARNING -- Mercury is highly toxic. Pay attention to ventilation when handling and avoid contact with skin and clothing. All kinds of strong acids shall be handled carefully and shall be handled in a fume hood. Unless otherwise specified, use only guaranteed reagents.
5.2.1 Water. The second-grade water specified in GB/T 6682.
5.2.2 Nitric acid.
5.2.3 Sulfuric acid.
5.2.9 Mercury standard working solution (0.1 µg/mL). Accurately pipette 1 mL of mercury standard intermediate solution (5.2.8), place it in a 100 mL volumetric flask, add the mixed acid solution (5.2.6) to dilute to the mark, and mix well. Prepare it fresh just before use.
5.3 Instruments and equipment
5.3.1 Cold atom mercury analyzer. It is equipped with a 50 mL reducing bottle.
5.3.2 Analytical balance. The sensitivity is 0.0001 g.
5.5 Test procedures
5.5.1 Preparation of sample solution Do two experiments in parallel. Weigh 1 g~5 g of the sample, accurate to 0.0001 g, place it in a 250 mL Erlenmeyer flask, add a few glass beads, add 25 mL of nitric acid (5.2.2) and 5 mL of sulfuric acid (5.2.3), and rotate the Erlenmeyer flask to prevent local carbonization. Install the condenser tube, heat over low heat, and stop heating when foaming begins. After foaming stops, reheat and reflux for 2 hours.
5.5.2 Standard curve drawing Accurately pipette 0 mL,
0.10 mL,
0.20 mL,
0.30 mL,
0.40 mL, and
0.50 mL of mercury standard working solution (5.2.9), which is equivalent to 0 µg, 0.01 µg, 0.02 µg, 0.03 µg, 0.04 µg, and 0.05 µg of mercury. Place them in the reduction bottles, add 10 mL of mixed acid solution (5.2.6) each, and then add 2 mL of stannous chloride solution (5.2.5); immediately close the reduction bottles tightly and react for 2 minutes; record the maximum absorbance of the cold atom mercury analyzer. Draw a standard curve with absorbance as the ordinate and mercury concentration as the abscissa.
5.6 Test data processing The mercury content w in the sample is expressed as a mass fraction, in milligrams per kilogram (mg/kg), and is calculated according to formula (2).
6 Direct injection method
6.1 Principle After the sample is dried at high temperature and catalytically pyrolyzed, the mercury is reduced to elemental mercury, which is enriched with gold amalgam or directly brought into the detector through a carrier gas, and the atomic absorption signal of mercury is measured at a wavelength of 253.7 nm, or the atomic fluorescence signal of mercury is detected with excitation by a mercury lamp; it is quantified by external standard method.
6.2 Reagents or materials WARNING -- Mercury is highly toxic. Pay attention to ventilation when handling and avoid contact with skin and clothing. All kinds of strong acids shall be handled carefully and shall be handled in a fume hood. Unless otherwise specified, use only guaranteed reagents.
6.3 Instruments and equipment
6.3.1 Direct injection mercury analyzer.
6.3.2 Analytical balance. The sensitivity is 0.0001 g.
6.3.3 Muffle furnace. The temperature control accuracy is ±20 °C.
6.3.4 Sample boat. It is made of nickel or quartz, burned in a muffle furnace at 550 °C±20 °C for 1 hour before use, taken out and placed in a desiccator to cool for later use.
6.5.1 Standard curve drawing Accurately pipette
0.1 mL of the low-concentration standard series solutions (6.2.7) and the high-concentration standard series solutions (6.2.8) respectively into the sample boats. The mercury masses of the low-concentration standard series solutions are 0 ng,
0.5 ng,
20.0 ng; the mercury masses of the high- concentration standard series solutions are
80.0 ng, 100 ng, 300 ng, and 500 ng.
6.5.2 Determination Weigh
0.05 g~
0.2 g of the sample (accurate to 0.0001
g) into the sample boat, measure on the machine, and calculate the mercury content in the sample according to the standard curve. Do a blank test at the same time.
6.5.3 Instrument reference conditions The reference conditions for the direct injection mercury analyzer are shown in Table 4 and Table 5.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB 7300.306-2025Feed additive - Part 3: Minerals and their complexes (or chelates) - Chromium nicotinate
- GB 7300.404-2025Feed additives - Part 4: Enzymes - beta-Mannanase
- GB 7300.405-2025Feed additives - Part 4: Enzymes - alpha-galactosidase
- GB 7300.505-2025Feed additives - Part 5: Live microorganisms - Bacillus coagulans
- GB 7300.506-2025Feed additives - Part 5: Live microorganisms - Lactobacillus delbrueckii subsp. lactis
- GB 7300.507-2025Feed additives - Part 5: Live microorganisms - Enterococcus faecalis
Similar standards
Editions of GB/T 13081
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 13081-2022 | Determination of mercury in feeds | current edition | Current |
| GB/T 13081-2006 | Determination of mercury in feeds | previous edition | Superseded |
This page sells the current edition, GB/T 13081-2022. Earlier editions are listed for reference only.
How to Buy GB/T 13081-2022
- 1Add to cart. Click the "Buy GB/T 13081-2022" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 20195-2024 — Animal feed - Preparation of test samples
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
Secure payment via Stripe
Payments accepted
GB/T 13081-2022
$125.00