Valid

GB 6932-2015Domestic gas instantaneous water heater (English PDF)

家用燃气快速热水器

Open the GB 6932-2015 preview as PDF

Preview — first pages of GB 6932-2015 (full document: 104 pages)

This is a limited preview

Buy now to download the full PDF (104 pages)

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Mandatory

Issue date

September 18, 2015

Implementation date

January 1, 2017

Scope

GB 6932-2015 is the English-translated version of 家用燃气快速热水器.

GB 6932-2015 is the Chinese national standard on domestic gas instantaneous water heater, in the field of domestic and commercial equipment, entertainment, sport. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 18 September 2015 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2017. Classification: ICS 97.120, CCS Y69. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB 6932-2015

National Standard of the People's Republic of China

ICS
97.120
Classification
Y69

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.2 Low calorific value netcalorificvalue Q
  • 4 Outdoor
  • 4.1 Classification
  • 4.2 Model
  • 4.2.2.2 Code JS
  • 4.2.2.3 Installation position and to exhaust mode D
  • 4.2.3.2 Code JN
  • 4.2.4.2 Code
  • 5 Materials and structural requirements
  • 5.1 Material
  • 5.1.1 General Materials
  • 5.1.2 Material in contact with the water
  • 5.1.3 Material gas line
  • 5.1.4 Materials burner
  • 5.2 Structure General Structure 5.2.1
  • 6 Dual-type heating and hot-water supply dual JL FIG. 7, FIG. 8
  • 7 Closed heating heater circulation passage to the atmosphere B of FIG. 6, FIG. 8
  • 22 Test Method
  • 99 The method of Annex H (normative) determining the ignition time at full load of

Foreword

This standard Chapter 5 5.1.6.1,5.1.6.2,5.2.2.2.1,5.2.2.8.1,5.2.2.8.2,5.2.2.9.1,5.2.3.1.1,5.2.3.2.1 , Item 5.2.3.3.1,5.2.3.4.1, Chapter 6 boldface in Table 6, Chapter 8 of 8.4.1.1,

9.1.1 in Chapter 9 of b),

9.1.2 of Item a),) item b, item c), 9.4.1, Appendix A A.2.2.2 of item

a) item, b), the term A.2.2.3 b), A.2.3.1, A.2.3.2.3 of

a) Xiang, boldface Table A.1, Appendix B Table B.1 boldface, Appendix C C.2.1, C.2.2, C.7.4 to the bold C.7.1 Portion, boldface bold portion of C.9.1 to C.9.3, C.13.1 to C.13.11 of the bold portion C.14.1 to C.14.5, Appendix F boldface items F.4.1.1, F.4.1.2, F.4.1.4 and first paragraph

a) are mandatory, others are recommended. This standard was drafted in accordance with rules GB/T 1.1-2009 given. The standard reference JISS2109.2008 "Gas Water Heater", EN26.1998 "Installation atmospheric household gas burner fast Fast food "(Amendments comprising 2 and 3). This standard replaces GB 6932-2001 "Domestic gas instantaneous water heaters." Compared with this standard GB 6932-2001, except for editorial changes Technical changes are as follows:

--- modified natural structure and the exhaust gas water heater installation requirements (see 5.1.6.1,5.1.6.2,5.2.2.8.1, F.4.1.1);

--- Natural increased water heater exhaust safety device to prevent incomplete combustion (see 5.2.3.3);

--- on the part concerning the structure and use of safe water heaters were perfect (see 5.1.1,5.1.2,5.1.5,5.2.3);

--- increase the gas/air ratio control apparatus according (see 5.2.2.11);

--- standard performance requirements, test methods were perfect (see Chapter 6, Section 7);

--- for domestic heating gas instantaneous water heaters, household gas instantaneous water heater dual-use part of the contents have been revised and improved (see Appendix A);

--- special requirements for increased condensing water heater (see Appendix B);

--- improve the safe use of alternating current electric water heater (see Appendix C);

1 Scope

GB 6932-2015 is the Chinese national standard on domestic gas instantaneous water heater, in the field of domestic and commercial equipment, entertainment, sport. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 18 September 2015 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2017. Classification: ICS 97.120, CCS Y69. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

This standard specifies a domestic gas water heater terms and definitions, and the classification models, materials and structural requirements, performance requirements, Standard Test Method, inspection rules and signs, installation, packaging, transportation and storage. This standard applies to domestic gas water heater hot-water supply load is not greater than the nominal heat of 70kW (hereinafter referred to as hot water heaters); Nominal heat is not greater than 70kW, working pressure is not greater than the maximum heating 0.3MPa, heating temperature not greater than 95 deg.] C to room Forced Vent type, home heating outdoor gas instantaneous water heater (hereinafter referred to as heating water heater) and a dual-type household gas instantaneous water heater (hereinafter Said dual heater), heating comprising condensing water heaters, water heaters, and heating heaters dual specific requirements. This standard does not apply to gas storage water heater.

Note 1. This standard gas referred to is GB/T 13611 "town gas classification and basic characteristics", a predetermined gas GB 13612 "artificial gas", using the GB/T 13611 When outside a predetermined gas, a gas test was carried out with gas provided by the product design, the relevant pressure range with reference to a predetermined GB/T 13611's.

Note 2. domestic gas water heater hot-water supply, heating domestic gas water heater, dual-type gas water heater household collectively domestic gas heat Water (hereinafter referred to as heater).

2 Normative references

The following documents for the application of this document is essential. For dated references, only applies to the version dated paper Pieces. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 191 Packaging Pictorial signs

GB/T 2828.1 Sampling procedures - Part 1. press-batch inspection sampling plan reception quality limit (the AQL) search

GB/T 2828.2 Sampling procedures - Part 2. Test batch sampling plan isolated by limiting quality (LQ) search

GB/T 3280 cold rolled steel and stainless steel

GB 4208 shell protection (IP code) Part 1

GB 4706.1-2005 Safety of household and similar electrical appliances. General requirements

GB/T 5013.1 rated voltage of 450/750V and Rubber insulated cables - Part 1. General Requirements

GB/T 5023.1 rated voltage of 450/750V and below PVC insulated cables - Part 1. General Requirements

GB/T 5465.2 electrical equipment Graphical symbols Part 2. Graphical symbols

GB/T 7306.1 55 ° pipe thread seal Part 1. the inner cylinder and the taper thread external thread

GB/T 7306.2 55 ° pipe thread seal Part 2. Taper internal and the external threads

GB/T 730755 ° non-sealing pipe thread

GB/T 12113-2003 touch current and protective conductor current measurement

3 Terms and Definitions

GB 4706.1-2005, GB/T 13611, GB 14536.1, GB 14536.6, GB/T 16411-2008, GB/T 17624.1 defined The following terms and definitions apply to this document.

3.1 Switch having a control linkage moisture gas combustion, utilizing the heat of combustion of the rapid heating device by the water flowing inside the heat exchanger.

3.2 Low calorific value netcalorificvalue Q

1 Under the standard condition 1m3 (or 1kg) complete combustion gas heat released, latent heat of the water vapor does not include the heat released.

3.3 Water temperature fluctuations temperaturefluctuation In the case where the water and the set water temperature remains constant, the difference between the maximum and minimum temperature of hot water.

3.4 Apply pressure appliedwaterpressure Water relative maximum and minimum values of the static pressure of the water heater can withstand normal operating manufacturer nameplate.

3.5 Heat load (heat flux) heatinput The fuel combustion heat released per unit time in the burner, i.e., the product gas of low heating value and the volume flow in the same state.

3.6 Nominal heat load (heat flux nominal) ratedheatinput Heat load under a predetermined reference atmospheric conditions. This value is the nominal value of the product nameplate, unit of kW (1kW = 3.6MJ/h).

3.7 Minimum heat load (minimum heat flux) minimumheatinput At a nominal gas pressure, thermal load is minimal when operating gas flow conditions.

3.8 Gas supply pressure gassupplypressure In the gas inlet of the water heater, measured relative static pressure at runtime.

3.9 Thermal efficiency thermalefficiency Effective use of incomplete combustion gas heat accounted for a percentage of the total heat release.

3.10 Hot water production capacity hotwaterproductioncapacity 0-2 gas condition, water heater at maximum heat load state, the water pressure was 0.1MPa, the conversion temperature Deltat = 25K Hot water per minute out of time.

3.11 Rated output hot water capacity ratedproductioncapacityofhotwater Product nameplate nominal value, hot water production capacity given by the manufacturer.

3.12 Water pressure watersupplypressure Measured at the inlet of a relative static pressure in normal use.

3.13 Flame-flamelift Burner flame from the fire hole to leave all or part of the phenomenon.

3.14 Tempering lightback Flame inside the burner ignites.

3.15 Huang Yan yelowflame (Contact with the cold body) to form a yellow flame at the top of the combustion flame cone.

4 Outdoor

4.1.4 Table 3 by use classification. Table 3 use classification Code schematic use categories using Type hot water supply for hot water supply is only JS JN heating type for heating only FIG. 5, FIG.

4.1 Classification

4.1.1 The use gas type heater, and the mounting position to the exhaust mode, the intended use, the heating hot water circulation means for categorizing.

4.1.2 divided by type of gas used. artificial gas water heaters, gas heaters, water heaters LPG. Classification of various gas Code and the rated supply pressure are shown in Table 1. Table

1 Gas Category Code Type of gas Rated gas supply pressure/Pa Artificial gas 3R, 4R, 5R, 6R, 7R 1000 natural gas 3T, 4T, 6T 1000 10T, 12T 2000 LPG 19Y, 20Y, 22Y 2800

4.1.3 installation position and by way of the exhaust gas to the classification shown in Table 2. Table 2 and to the mounting position of the exhaust way classification Code Name schematic classification of content referred to Natural exhaust type From the combustion chamber when the air required by the exhaust pipe from However, the suction force of the flue gas to the outside row Flue D in FIG.

1 Forced exhaust When combustion air is taken from the desired chamber, through the action of the fan under Forced through the flue gas exhaust pipe to the outside row Q strong emission FIG. 2a),

b) Natural to exhaust Will exhaust pipe connected to the outdoor use of natural suction force chamber External air supply and exhaust fumes to the outside P balanced FIG 3a) Forced to exhaust An exhaust pipe connected to the outdoor will by forcing blower chamber External air supply and exhaust fumes to the outside G forced to exhaust FIG. 3b) FIG outdoor food Outdoor W can only be installed outdoors 4 FIG indoor NATURAL vent type 1

b) the wind type FIG

4.2 Model

4.2.1 Model Type Type hot-water heater is divided into food, heating, dual heater, condensing water heater.

4.2.2 hot water heater models

4.2.2.1 constitute

4.2.2.2 Code JS

--- represents domestic hot water gas instantaneous water heater for heating water.

4.2.2.3 Installation position and to exhaust mode D

--- Natural exhaust type; Q

--- forced exhaust; P

--- Natural to exhaust; G

--- forced to exhaust; W

4.2.2.4 main parameters The rated thermal load (kW) digits after rounding.

4.2.2.5 Characteristics No. We designed by the manufacturer, the number of bits is not limited. Example.

4.2.3 heating, water heaters, dual-use model

4.2.3.1 constitute

4.2.3.2 Code JN

--- represents a heating home heating gas water heater; JL

--- represents a domestic hot water heating and dual-use gas water heater.

4.2.3.3 installation position and to exhaust mode With 4.2.2.3.

4.2.3.4 cycle way K

4.2.3.5 main parameters The rated heat input (kW) after taking the whole digit.

4.2.3.6 Characteristics No. We designed by the manufacturer, the number of bits is not limited. Example.

4.2.4 condensing water heater models

4.2.4.1 constitute In addition to the code should be consistent with

4.2.3 heating hot water heaters, models constitute rules of dual-use water heaters.

4.2.4.2 Code

--- represents JSL condensing heating household water gas instantaneous water heater for heating water; Heating the JNL

--- represents a household condensation heating gas water heater; JLL

--- denotes a condensation type hot water supply and home dual-type gas instantaneous water heater's heating. Example 1. Example 2.

4.2.5 font format Type the characters that appear in all uppercase characters.

5.1.1 General Materials

5.1.1.1 during the normal life of the heater, the material should be able to withstand the contemplated mechanical, chemical and thermal effects.

5.1.1.2 material in contact with the gas and combustion products, should be corrosion resistant or corrosion-resistant after treatment.

5.1.1.3 combustion chamber housing should be made of metal material.

5.1.1.4 material involving water heater safety changes, its characteristics manufacturer shall be guaranteed.

5.1.1.5 in contact with an acidic material should be resistant to corrosion or condensate with a protective corrosion resistant coating.

5.1.1.6 prohibit the use of asbestos-containing materials.

5.1.2 Material in contact with the water

5.1.2.1 metallic material in contact with water, during the service life, the material should guarantee against corrosive effects, shall withstand the mechanical, chemical and thermal Movies Ring, and should not pollute the water.

5.1.2.2 plastic materials in contact with water during the service life, the material should meet the mechanical, physical and chemical performance requirements, UV resistance, aging, corrosion The impact should not pollute the water.

5.1.2.3 Other nonmetallic and auxiliary materials, rubber, sealants, adhesives and lubricants used in the moving parts in contact with water or the like, not dirty Dyed water quality.

5.1.3 Material gas line

5.1.3.1 piping system components should be corrosion resistant, m.p. than 350 °C metallic material or a non-combustible material (sealing, the lubricating material except).

5.1.3.2 made in copper or soft copper tube and to the surface treatment of carbon steel for a gas delivery tube, the inner tube surface for corrosion protection coating Layer treated to prevent corrosion of sulfide gas.

5.1.3.3 The materials used, such as oil seal, gasket, etc. In addition to meeting the performance requirements of a seal, the gas should be corrosion-resistant.

5.1.4 Materials burner

5.1.4.1 burner should be corrosion-resistant, metallic material melting point greater than 700 deg.] C or non-combustible materials, may not affect the use of the defect.

5.1.4.2 burner flame port portions of the above stainless steel or equivalent corrosion and temperature resistant materials should be used.

5.1.4.3 nozzle, nozzle carriage, adjustable air board should be made of metal or non-combustible materials deg.] C melting point greater than 500, and has a corrosion resistance. twenty one

5.1.4.4 ignition burner air supply pipe of a metal material is not less than the inner diameter 2mm, melting point greater than 500 deg.] C should be used.

5.1.5 heat exchanger material The heat exchanger is connected to the hot water heater and the combustion chamber, should be corrosion resistant, is greater than the melting point of the metal material 700 deg.] C.

5.1.6 material by means of the flue gas

5.1.6.1 NATURAL exhaust gas water heater exhaust pipe should be made of metal or corrosion resistant surface is corrosion-resistant material over the metal, Which should meet the corrosion UV and long-term outdoor use of anti-rust capability, the thickness of the metallic material should satisfy the necessary wind energy Force (lateral load is applied to 1.5kN/m2 in the exhaust pipe side). Shall not be used as a natural aluminum corrugated tube water heater exhaust gas exhaust pipe.

5.1.6.2 forced exhaust, natural to exhaust, forced exhaust pipe to the exhaust gas water heater is equipped with an exhaust pipe or to the thickness should be not less To

0.3 mm (nominal dimensions) and in the stainless steel of austenitic steel in 3280 GB/T , or the thickness not less than 0.8mm (nominal ruler Inch) carbon steel plate treated sided enamel, or equivalent level with more corrosion-resistant, flame temperature, and other material properties. The sealing member, the pad should be A flexible corrosion-resistant materials.

5.1.7 Case Material Corrosion-resistant materials should be used or a corrosion-resistant surface over which the sealing member, a flexible pad with corrosion-resistant materials. Outdoor hot Water trap housing should also conform to the requirements of UV resistance.

5.2 Structure General Structure 5.2.1

5.2.1.1 heater member should take into account the design and manufacture of safe, strong and durable, reliable overall structure, not during normal operation Due to damage or affect the use of functional failure.

5.2.1.2 portion of each connecting member (e.g., bolts, etc.) should be strong, reliable, food can be easily fixed to the wall or the floor, can not use Loose.

5.2.1.3 The water should penetrate into the gas passage.

5.2.1.4 can produce a self-tapping screw type can not be applied to the chips based on the gas communicating passage portion.

5.2.1.5 food designed to be easy to clean and service, parts of the surface should be smooth hand may contact mus...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 104 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB 6932

EditionTitleRevisionStatus
GB 6932-2015Domestic gas instantaneous water heatercurrent editionCurrent
GB 6932-1986previous editionSuperseded

This page sells the current edition, GB 6932-2015. Earlier editions are listed for reference only.

How to Buy GB 6932-2015

  1. 1Add to cart. Click the "Buy GB 6932-2015" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
104 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 6932-2015

$1,170.00

$995.00for partners