Scope
GB 26851-2011 is the English-translated version of 火灾声和/或光警报器.
GB 26851-2011 specifies the classification, requirements, tests, inspection rules and marking of audible and/or visual fire alarm signaling appliances installed in general industrial and civil buildings; appliances with special performance used in other environments also follow it, unless other standards set special requirements.
Appliances are classified by purpose (audible, visual, audible and visual, gas release alarm) and by place of use (indoor, for dwellings or non-dwellings, and outdoor).
The requirements cover sound pressure level (at least 75 dB(A) and at most 120 dB(A) at 3 m, with a 3 s to 5 s low-to-high start for dwelling units), flash frequency of 1 Hz to 2 Hz and visibility at 25 m, luminance of gas release signs, 4 h operational reliability, voltage fluctuation, insulation resistance, 1 250 V electric strength, electromagnetic compatibility, climatic and mechanical endurance, IP33 for outdoor units and instructions for use.
Clause 5 sets out the test methods on six specimens, followed by inspection rules and marking; clauses 4, 6 and 7 are mandatory, and the standard references EN 54-3:2001.
It is the first edition. Issued on 29 July 2011, in force since 1 January 2012. Classification: ICS 13.220.20, CCS C81. The document runs to 15 pages, delivered complete in English translation.
Found what you need?
Document preview — GB 26851-2011
National Standard of the People's Republic of China
- ICS
- 13.220.20
- Classification
- C81
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Classification
- 4 Requirements
- 5 Tests
- 6 Inspection rules
- 7 Marking
3 Classification
4 Requirements
5 Tests
6 Inspection rules
7 Marking
Foreword
Clauses 4, 6 and 7 of this standard are mandatory; the rest are recommended.
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard makes reference to EN 54-3:2001 "Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders".
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights.
This standard was proposed by the Ministry of Public Security of the People's Republic of China.
This standard is under the jurisdiction of the National Technical Committee on Fire Protection of Standardization Administration of China (SAC/TC 113).
Organization in charge of drafting this standard: Shenyang Fire Research Institute of the Ministry of Public Security.
Organizations participating in drafting this standard: Xi'an Shengsaier Electronic Co., Ltd., Hunan Gaocheng Fire Industry Co., Ltd., Zhejiang Hengzhou Electronic Industry Co., Ltd.
Main drafters of this standard: Wang Xuelai, Lin Qiang, Li Rui, Deng Lihong, Shao Yu, Zhao Yu, Guan Mingyang, Wu Lilong, Ding Hongjun.
This standard is issued for the first time.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 9969General principles for preparation of instructions for use of industrial products
- GB 12978Rules for test of fire electronic products
- GB 16838Environmental test and severities for fire electronic products
- GB/T 17626.2Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.3Electromagnetic compatibility - Testing and measurement techniques - Part 3: Radiated, radio-frequency, electromagnetic field immunity test
- GB/T 17626.4Electromagnetic compatibility -- Testing and measurement techniques -- Electrical fast transient/burst immunity test
GB 4208
Similar standards
Editions of GB 26851
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 26851-2011 | Audible and/or visual fire alarm signaling appliances | current edition | Current |
This page sells the current edition, GB 26851-2011. Earlier editions are listed for reference only.
How to Download GB 26851-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 12978-2003 — Rules for test of fire electronic products
GB 12978-2025 — Rules for test of fire electronic products
GB 16838-2005 — Environmental test and severities for fire electronic products
Secure payment via Stripe
Payments accepted
GB 26851-2011
$115.00