GB/T 45839-2025General technical requirements for networking of self-contained fire detection and alarm devices (English PDF)

独立式火灾探测报警器组网通用技术要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (23 pages)

Need quotation for your management?

Get a formal quotation for GB/T 45839-2025 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 30, 2025

Implementation date

June 1, 2026

Scope

GB/T 45839-2025 is the English-translated version of 独立式火灾探测报警器组网通用技术要求.

China's national standard for joining self-contained fire alarms into a network. A self-contained smoke or heat alarm, or a household gas detector, is built to work alone: it senses, it sounds, and nobody outside the room knows.

That is enough when someone is at home and awake, and it is not enough in rented rooms, small shops, old residential blocks and the homes of elderly people living alone, which is where these devices are most often installed precisely because a full fire alarm system is not.

Networking the alarms over a wireless link lets the alarm reach an on-site platform, a manufacturer's remote management platform, a central platform run by the authorities and the phones of the owner, the property manager and the maintenance staff.

The standard classifies such networks by architecture, direct access or aggregated access through a transceiver, and by the power supply of the field devices, and specifies the requirements for the devices, the transceiver, fire and fault alarm functions, wireless communication, power supply, the platforms and the mobile software, insulation, electric strength and electromagnetic compatibility, with normative annexes on the network architecture, the device identity code, wireless testing and the HTTPS API data format that lets platforms from different makers exchange data.

Its first rule is that the network must never weaken the alarm: an open circuit, a short circuit or a failure of the network function shall not affect the device's own alarm.

It is used by manufacturers, platform operators, fire authorities and testing bodies.

Found what you need?

Document preview — GB/T 45839-2025

National Standard of the People's Republic of China

ICS
13.220.20
Classification
C 81

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Classification
  • 5 Requirements
  • 5.1 General
  • 5.2 Appearance
  • 5.3 Transceiver
  • 5.4 Fire alarm function
  • 5.5 Fault alarm function
  • 5.6 Wireless communication function
  • 5.7 Power supply performance
  • 5.8 General performance of platforms
  • 5.9 On-site platform
  • 5.10 Remote management platform for manufacturer
  • 5.11 Remote management platform for management authority
  • 5.12 Mobile software
  • 5.13 Insulation resistance
  • 5.14 Electric strength
  • 5.15 Electromagnetic compatibility
  • Annex A (normative) Network architecture
  • Annex B (normative) Identification code
  • Annex C (normative) Wireless tests
  • Annex D (normative) HTTPS API data transmission format for on-site platforms and remote management platforms

Foreword

GB/T 45839-2025 was issued on 30 May 2025 by the State Administration for Market Regulation and the Standardization Administration of the People's Republic of China, and has been in force since 1 June 2026. The /T in the designation marks it as a recommended national standard. It is a first edition.

This document was drafted in accordance with the rules given in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights.

This document was proposed by the National Fire and Rescue Administration and is under the jurisdiction of the National Technical Committee on Fire Protection of Standardization Administration of China (SAC/TC 113).

Drafting organizations: Shenyang Fire Research Institute of the Ministry of Emergency Management, Liaoning Provincial Fire and Rescue Corps, University of Electronic Science and Technology of China, Jade Bird Fire Co., Ltd., Shenzhen Taihe'an Technology Co., Ltd., Zhongxiaolian (Shenzhen) Smart Fire Innovation Technology Co., Ltd., Qingdao Topscomm Fire Safety Co., Ltd., Xi'an Shengsaier Electronics Co., Ltd., Beijing Lida Huaxin Electronics Co., Ltd., Shandong Longcheng Fire Technology Co., Ltd.

1 Scope

China's national standard for joining self-contained fire alarms into a network. A self-contained smoke or heat alarm, or a household gas detector, is built to work alone: it senses, it sounds, and nobody outside the room knows. That is enough when someone is at home and awake, and it is not enough in rented rooms, small shops, old residential blocks and the homes of elderly people living alone, which is where these devices are most often installed precisely because a full fire alarm system is not. Networking the alarms over a wireless link lets the alarm reach an on-site platform, a manufacturer's remote management platform, a central platform run by the authorities and the phones of the owner, the property manager and the maintenance staff. The standard classifies such networks by architecture, direct access or aggregated access through a transceiver, and by the power supply of the field devices, and specifies the requirements for the devices, the transceiver, fire and fault alarm functions, wireless communication, power supply, the platforms and the mobile software, insulation, electric strength and electromagnetic compatibility, with normative annexes on the network architecture, the device identity code, wireless testing and the HTTPS API data format that lets platforms from different makers exchange data. Its first rule is that the network must never weaken the alarm: an open circuit, a short circuit or a failure of the network function shall not affect the device's own alarm. It is used by manufacturers, platform operators, fire authorities and testing bodies.

This document specifies the classification of and requirements for networking systems of self-contained fire detection and alarm devices.

This document applies to the construction and operation of networks of self-contained fire detection and alarm devices.

2 Normative references

The contents of the following documents constitute indispensable provisions of this document through normative references in the text. For dated references, only the edition corresponding to that date applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB 4717 Fire alarm control units.

GB 14287.2 Electrical fire monitoring system - Part 2: Residual current electrical fire monitoring detectors.

GB 14287.3 Electrical fire monitoring system - Part 3: Temperature sensing electrical fire monitoring detectors.

GB 14287.4 Electrical fire monitoring system - Part 4: Arc fault detectors.

GB 15322.1 Combustible gas detectors - Part 1: Point-type combustible gas detectors for industrial and commercial use.

GB 15322.2 Combustible gas detectors - Part 2: Household combustible gas detectors.

GB 19880 Manual fire alarm call points.

GB 20517 Self-contained smoke alarms.

GB 22370 Household fire safety system.

GB 26851 Fire alarm sounders and/or visual alarm devices.

GB 30122 Self-contained heat alarms.

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 networking of self-contained fire detection and alarm devices - a fire monitoring and early warning system formed, wholly or partly by wireless communication links, of field devices such as self-contained fire detection and alarm devices, manual fire alarm call points, transceivers, fire alarm sounders and/or visual alarm devices and loudspeakers/public address, together with household fire safety systems, on-site platforms and remote management platforms. NOTE Self-contained fire detection and alarm devices include self-contained smoke alarms, self-contained heat alarms, self-contained combustible gas detectors, household combustible gas detectors and self-contained electrical fire monitoring detectors.

3.2 alarm trigger device - a device that sends an alarm signal to the platform by sensing changes in physical or chemical phenomena of the monitored object that are related to fire and fire risk. NOTE Alarm trigger devices include self-contained fire detection and alarm devices and manual fire alarm call points.

3.3 on-site platform - a management terminal in the protected area on site that receives and processes, directly or indirectly, the information of the devices and has independent control output functions such as issuing fire alarm signals. NOTE The on-site platform may be replaced by a fire alarm control unit or by the monitoring equipment of a control centre.

3.4 remote management platform - a terminal outside the protected area on site that receives and processes the information of the networking system and performs comprehensive management. NOTE Remote management platforms include the remote management platform for the manufacturer and the remote management platform for the management authority.

3.5 remote management platform for manufacturer - a terminal outside the protected area used by a manufacturer to manage the networking system products it has produced.

3.6 remote management platform for management authority - a terminal outside the protected area used by a management authority to manage networking systems of self-contained fire detection and alarm devices.

3.7 collection and transmission device (transceiver) - a device in the networking system used to collect and forward the information of the alarm trigger devices (or household fire safety systems), fire alarm sounders and/or visual alarm devices and loudspeakers/public address in the protected area on site.

3.8 identification code; ID - the unique identity code of each device in the networking system.

4 Classification

4.1 According to the network architecture (as required by Annex A), networking systems of self-contained fire detection and alarm devices (hereinafter referred to as systems) are divided into: a) direct access type, in which the field devices communicate with the on-site platform without passing through a transceiver; b) aggregated access type, in which the field devices communicate with the on-site platform through a transceiver.

4.2 According to the power supply, the field devices of the system may be divided into: a) internal battery powered only; b) external power supply only; c) external power supply with internal battery. NOTE The external power supply only type is limited to self-contained combustible gas detectors, household combustible gas detectors and self-contained electrical fire monitoring detectors.

5.1 General

5.1.1 An open circuit or short circuit of the external network connection of a self-contained fire detection and alarm device, or a failure of the networking function, shall not affect the device's own alarm function.

5.1.2 The devices of the system shall meet the following: self-contained smoke alarms comply with GB 20517; self-contained heat alarms comply with GB 30122; self-contained point-type combustible gas detectors for industrial and commercial use comply with GB 15322.1, and household combustible gas detectors with GB 15322.2; self-contained residual current electrical fire monitoring detectors comply with GB 14287.2, self-contained temperature sensing electrical fire monitoring detectors with GB 14287.3 and self-contained arc fault detectors with GB 14287.4; manual fire alarm call points comply with GB 19880; fire alarm sounders and/or visual alarm devices comply with GB 26851; household fire safety systems comply with GB 22370.

5.1.3 The system shall have a time synchronization function.

5.1.4 The networking method and network type of the system may be chosen according to the needs of use.

5.2 Appearance

The surfaces of all devices of the system shall be free from corrosion, peeling and blistering of coatings, and from obvious mechanical damage such as scratches, cracks and burrs, and the fastened parts of the devices shall not be loose.

5.3 Transceiver

Clause 5.3 limits the number of nodes that a transceiver should receive and forward, with larger transceivers tested at the number of points declared by the manufacturer. The transceiver shall be powered by external power supply with internal battery and shall have indicator lamps for normal operation, fault, external power supply normal and fault, and internal battery normal and fault; the normal state indications shall be green and the fault indications yellow.

The transceiver shall record and store the alarm and fault information of all the alarm trigger devices connected to it, the working state of the sounders, visual alarm devices or loudspeakers/public address, fault and control output information, with the corresponding year, month, day, hour, minute and second, shall be able to export the records in time order, and shall hold not less than the number of records specified.

5.4 Fire alarm function

Clause 5.4 sets the maximum time within which each alarm trigger device and household fire safety system shall transmit its fire alarm signal to the on-site platform, and the maximum time for alarm information to pass between the on-site platform and the remote management platform.

The on-site platform shall receive the fire alarm signals of all the alarm trigger devices and household fire safety systems of the system, emit audible and visual fire alarm signals, indicate the location of the alarm and maintain it until the on-site platform is manually reset. The audible signal shall be capable of being silenced manually and shall start again when a further alarm signal is received.

The system shall be able to receive a specified minimum number of independent fire alarm signals within a specified time, related, for large transceivers, to the number of points declared by the manufacturer.

Besides being silenced at its own protected location, the audible signal of a self-contained alarm in the system may be silenced through the on-site platform or the remote management platform by a registered user authorized by the owner, and a record of the silencing operation shall be kept.

5.5 Fault alarm function

When any of the following faults occurs, the on-site platform shall, within the time specified, emit audible and visual fault signals clearly distinguishable from the fire alarm signals and indicate the location of the fault: a) a fault of the main body of an alarm trigger device; b) the main body of an alarm trigger device detached from its base; c) loss of connection between the main body of an alarm trigger device and its wireless transmission part (where these are separate); d) a fault of the external power supply or internal battery that does not affect normal communication; e) a communication fault between a transceiver and the on-site platform. The audible fault signal shall be capable of being silenced manually and shall start again on a further fault input; the visual fault signal shall be maintained until the fault is cleared.

Communication faults between the alarm trigger devices, sounders, visual alarm devices and loudspeakers and the on-site platform (direct access systems) or the transceiver (aggregated access systems) shall likewise be signalled and located by the on-site platform, within a longer specified period. Fault information shall pass between the on-site platform and the remote management platform within the time specified; the on-site platform shall display all fault information, with any information not displayed at the same time retrievable manually; and no fault in the system shall affect the normal operation of the parts that are not faulty.

5.6 Wireless communication function

5.6.1 Each device of the system shall have a unique, authorized identification code, coded in accordance with Annex B.

5.6.2 Where devices of the system transmit information over cellular wireless networks in licensed spectrum, encryption measures shall be applied.

5.6.3 Devices using a self-built wireless communication network shall communicate normally in the network environment set up by the manufacturer.

5.6.4 Devices using cellular wireless networks in licensed spectrum shall communicate normally in the network environment declared by the manufacturer and shall be able to search automatically for an available cell to communicate with.

5.6.5 Devices communicating wirelessly shall monitor the quality of the wireless signal, meeting 5.6.3 and 5.6.4, and shall report it when switched on and periodically during normal monitoring.

5.6.6 The wireless communication functions of 5.6.1 to 5.6.5 shall be verified by the wireless tests of Annex C.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 45839-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
23 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 45839-2025

$390.00