GB 14287.2-2026Electrical fire monitoring system - Part 2: Residual current electrical fire monitoring detector (English PDF)
电气火灾监控系统 第2部分:剩余电流式电气火灾监控探测器
Open the GB 14287.2-2026 preview as PDF
This is a limited preview
Buy now to download the full PDF (40 pages)
Issued by
SAMR; SAC
Level / Type
National · Mandatory
Issue date
January 28, 2026
Implementation date
August 1, 2027
Scope
GB 14287.2-2026 is the English-translated version of 电气火灾监控系统 第2部分:剩余电流式电气火灾监控探测器.
The 2026 edition of Part 2 of GB 14287 rewrites the standard for residual current electrical fire monitoring detectors and roughly triples its length: twenty-four clauses of technical requirements and thirty-one test methods against the eight-clause structure of the 2014 text. It covers the classification, the alarm and monitoring functions, the communication with the control unit, the electrical safety and electromagnetic compatibility, the mechanical and climatic endurance, and adds normative annexes on the burning behaviour of the enclosure and on the residual current sensor. It replaces GB 14287.2-2014 from 1 August 2027, which is the date by which a manufacturer has to have requalified the product. Issued on 28 January 2026. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the edition it replaces are taken from there. The clause text, the tables and the numeric limits are not reproduced on this page - they are in the document itself, which is delivered in full in English translation.
Document preview — GB 14287.2-2026
National Standard of the People's Republic of China
- Replacing
- GB 14287.2-2014
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1.Scope1
- 2 Normative References1
- 3.Terms and Definitions1
- 5 Technical Requirements4
- 5.1 General Requirements4
- 5.2 Appearance4
- 5.3 Performance of Major Components4
- 5.4 Basic Functions6
- 5.5 Electrical parameter monitoring function7
- 5.6 Alarm control function7
- 5.7 Communication Functions8
- 5.8 Repeatability8
- 5.9 Consistency8
- 5.10 Compatibility with various residual current sensors8
- 5.11 High Current Surge Adaptability8
- 5.12 Harmonic Adaptability10
- 5.13 High-frequency load adaptability10
- 5.14 Capacitive current suppression10
- 5.15 Dynamic Residual Current Adaptability10
- 5.16 Insulation resistance11
- 5.17 Leakage current11
- 5.18 Electrical strength11
- 5.19 Electromagnetic Compatibility11
- 5.20 Voltage fluctuation12
- 5.21 Operational stability12
- 5.22 Mechanical environmental tolerance12
- 5.23 Climate and Environmental Tolerance13
- 5.24 Instruction Manual13
- 6.Test Methods13
- 6.1 General Requirements13
- 6.2 Appearance and performance inspection of major components15
- 6.3 Monitoring and Alarm Function Test16
- 6.4 Fault Alarm Function Test18
- 6.5 Electrical Parameter Monitoring Function Test (Applicable only to samples with this function)18
- 6.6 Alarm Control Function Test (Applicable only to stand-alone specimens)18
- 6.7 Communication Function Test19
- 6.8 Repeatability Test19
- 6.9 Consistency Test (applicable only to split-type specimens)19
- 6.10 Compatibility Test of Multiple Residual Current Sensors19
- 6.11 High Current Impact Adaptability Test20
- 6.12 Harmonic Adaptability Test (Applicable only to AC type samples)21
- 6.13 High-frequency load adaptability test (applicable only to AC type samples)22
- 6.14 Capacitive current suppression test (applicable only to samples with resistive residual current detection function)22
- 6.15 Dynamic Residual Current Adaptability Test (Applicable only to DC-type samples)23
- 6.16 Insulation Resistance Test23
- 6.17 Leakage Current Test24
- 6.18 Electrical strength test24
- 6.19 Radio Frequency Electromagnetic Field Radiation Immunity Test24
- 6.20 Conducted Interference Immunity Test by Radio Frequency Field Induction24
- 6.21 Electrostatic Discharge Immunity Test25
- 6.22 Electrical Fast Transient/Bulk Immunity Test25
- 6.23 Surge (Impulse) Immunity Test25
- 6.24 Immunity test for voltage sags, short interruptions and voltage variations25
- 6.25 Power Frequency Magnetic Field Immunity Test26
- 6.26 Voltage Fluctuation Test (Applicable only to samples powered by a 220V/50Hz AC power supply)26
- 6.27 Operational stability test26
- 6.28 Vibration (Sine) (Running) Test26
- 6.29 Crash Test27
- 6.30 Low Temperature (Operation) Test27
- 6.31 Constant Humidity and Heat (Operation) Test27
- 7.Inspection Rule27
- 7.1 Factory Inspection27
- 7.2 Type Testing28
- 8.Markings and Packaging28
- 8.1 Product Marking28
- 8.2 Quality Inspection Marks28
- 8.3 Marking durability28
- 33 References36
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part
1.Structure and Drafting Rules of Standardization Documents". Drafting. This document is Part 2 of GB 14287 "Electrical Fire Monitoring Systems". GB 14287 has the following parts published.
1.Electrical Fire Monitoring Equipment;
2.Residual Current Type Electrical Fire Monitoring Detector;
3.Temperature-measuring electrical fire monitoring detectors;
4.Fault Arc Detectors;
5.Measurement of Pyrolytic Particle Electrical Fire Monitoring Detectors;
6.Harmonic Suppression Electrical Fire Monitoring Devices;
7.Electrical Fire-Resistant Current-Limiting Protective Devices;
9.Electrical fire monitoring detectors that detect insulation performance. This document replaces GB 14287.2-2014 "Electrical Fire Monitoring Systems - Part
2.Residual Current Type Electrical Fire Monitoring and Detection". Compared with GB 14287.2-2014, the main technical changes in the "Apparatus" standard, apart from structural adjustments and editorial modifications, are as follows:
a) Added the terms "residual current", "AC residual current", "resistive residual current", "capacitive residual current", "DC residual current", and "stable" "Static residual current", "Dynamic residual current", "Split-type residual current electrical fire monitoring detector", "Integrated residual current electrical fire detector" "Gas fire monitoring detector", "AC type residual current type electrical fire monitoring detector", "DC type residual current type electrical fire monitoring detector" "Controlled detector", "single-sensor electrical fire monitoring detector", "system leakage capacitance" and their definitions (see 3.1, 3.1.1, 3.1.1.1,...). 3.1.1.2, 3.1.2, 3.1.2.1, 3.1.2.2, 3.4.3, 3.4.4~3.4.6, 3.5, 3.7); the residual current sensor and signal processing were modified. Unit-type residual current electrical fire monitoring detector, stand-alone residual current electrical fire monitoring detector, non-stand-alone Definitions of residual current type electrical fire monitoring detectors and multi-sensor combination type electrical fire monitoring detectors (see 3.2~3.4). 3.4.1, 3.4.2, 3.6 (and 3.5, 3.6, 3.1~
3.4 in the.2014 edition);
b) Added classification requirements based on the connection method between the sensing element and the signal processing unit, and based on the type of monitored current (see 4.3, 4.4);
1 Scope
The 2026 edition of Part 2 of GB 14287 rewrites the standard for residual current electrical fire monitoring detectors and roughly triples its length: twenty-four clauses of technical requirements and thirty-one test methods against the eight-clause structure of the 2014 text. It covers the classification, the alarm and monitoring functions, the communication with the control unit, the electrical safety and electromagnetic compatibility, the mechanical and climatic endurance, and adds normative annexes on the burning behaviour of the enclosure and on the residual current sensor. It replaces GB 14287.2-2014 from 1 August 2027, which is the date by which a manufacturer has to have requalified the product. Issued on 28 January 2026. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the edition it replaces are taken from there. The clause text, the tables and the numeric limits are not reproduced on this page - they are in the document itself, which is delivered in full in English translation.
This document defines the terminology for residual current type electrical fire monitoring detectors, and specifies their classification, technical requirements, inspection rules, marking, and packaging. The description of the corresponding experimental methods is as follows: This document applies to residual current type electrical fire monitoring detectors (hereinafter referred to as "detectors") in electrical fire monitoring systems. Design, manufacturing, and inspection.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.
GB/T 9969 General Rules for Instructions for Use of Industrial Products
GB 12978 Inspection Rules for Fire Protection Electronic Products
GB 14287 (all parts) Electrical fire monitoring systems
GB/T 16838 Environmental testing methods and severity levels for fire protection electronic products
GB/T 17626.2 Electromagnetic compatibility testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3 Electromagnetic compatibility testing and measurement techniques - Part
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 residual current In a circuit composed of charged conductors such as the phase line and neutral line in an AC system, and the positive and negative polarity lines in a DC system, the instantaneous value of the circuit current is calculated according to... The effective value is calculated using vector sums (AC) or algebraic sums (DC).
3.1.1 AC residual current In an AC power distribution system, the effective value of the vector sum of the instantaneous values of the loop currents formed by the phase line and the neutral line.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 40 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 9969General principles for preparation of instructions for use of industrial products
- GB 12978Rules for test of fire electronic products
- GB/T 16838Environmental test and severities for fire electronic products
GB 14287 · GB/T 17626.2 · GB/T 17626.3
Cited by
- GB/T 45839-2025General technical requirements for self-contained fire detectors networking
- GB 14287.3-2014Electrical fire monitoring system - Part 3: Temperature sensing electrical fire monitoring detectors
- GB 29837-2013Maintenance and discard for fire detection and alarm products
- GB 22370-2008Fire alarm and safety system for household
Editions of GB 14287.2
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 14287.2-2026 | Electrical fire monitoring system - Part 2: Residual current electrical fire monitoring detector | current edition | Current |
| GB 14287.2-2014 | Electrical fire monitoring system - Part 2: Residual current electrical fire monitoring detector | previous edition | Superseded |
This page sells the current edition, GB 14287.2-2026. Earlier editions are listed for reference only.
How to Buy GB 14287.2-2026
- 1Add to cart. Click the "Buy GB 14287.2-2026" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 12978-2003 — Rules for test of fire electronic products
GB 12978-2025 — Rules for test of fire electronic products
GB 14287.1-2014 — Electrical fire monitoring system - Part 1: Electrical fire monitoring equipment
Secure payment via Stripe
Payments accepted
GB 14287.2-2026
$650.00