Scope

GB 16808-2025 is the English-translated version of 可燃气体报警控制器.

China's mandatory national standard for combustible gas alarm control units. The control unit is the panel that gathers the signals from gas detectors and decides what to do: raise the alarm, close a valve, start ventilation, shut down a plant. Because it is the point where detection becomes action, its failure modes matter more than a detector's. A unit that fails silently leaves a plant unprotected while everyone believes it is monitored, so the standard requires that faults - a broken cable, a failed detector, a lost supply - be detected and signalled as faults rather than ignored, and distinguished from a gas alarm so that the response is right. Around that sit the two alarm thresholds, typically at a fifth and two fifths of the lower explosive limit, the response and reset behaviour, the battery endurance, and the electromagnetic compatibility of equipment that lives in an industrial environment.

Document preview — GB 16808-2025

National Standard of the People's Republic of China

ICS
13.220.20
Classification
C81

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and Definitions1
  • 4 Categories2
  • 5 Technical Requirements2
  • 5.1 General Requirements2
  • 5.2 Appearance requirements2
  • 5.3 Performance of main components (devices)2
  • 5.4 Ground terminal3
  • 5.5 Overall performance4
  • 5.6 Insulation resistance9
  • 5.7 Leakage Current9
  • 5.8 Electric strength9
  • 5.9 Electromagnetic compatibility performance9
  • 5.10 Climate and environmental tolerance10
  • 5.11 Mechanical environmental resistance11
  • 6 Test Methods12
  • 6.1 General Requirements12
  • 6.2 Combustible gas alarm function test13
  • 6.3 Combustible gas alarm control function test13
  • 6.4 Fault alarm function test14
  • 6.5 Combustible gas concentration display function test14
  • 6.6 Shielding function test14
  • 6.7 Self-check function test15
  • 6.8 Information display and query function test15
  • 6.9 Communication function test with the graphic display device in the fire control room15
  • 6.10 System compatibility function test15
  • 6.11 Power supply function test15
  • 6.12 Insulation resistance test16
  • 6.13 Leakage current test16
  • 6.14 Electric strength test16
  • 6.15 Radio frequency electromagnetic field radiation immunity test17
  • 6.16 Radio frequency field induced conducted disturbance immunity test17
  • 6.17 Electrostatic discharge immunity test17
  • 6.18 Electrical fast transient burst immunity test17
  • 6.19 Surge (impact) immunity test18
  • 6.20 Voltage dips, short interruptions and voltage variations immunity test18
  • 6.21 Power supply transient test18
  • 6.22 Low temperature (operation) test18
  • 6.23 High temperature (operation) test19
  • 6.24 Steady-state damp heat (operation) test19
  • 6.25 Steady-state damp heat (durability) test19
  • 6.26 Vibration (sinusoidal) (operating) test19
  • 6.27 Crash Test20
  • 7 Inspection Rules20
  • 7.1 Product factory inspection20
  • 7.2 Type inspection20
  • 8 Sign21
  • 8.1 Product Labeling21
  • 22 Reference26

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part

1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB 16808-2008 "Combustible Gas Alarm Controller". Compared with GB 16808-2008, except for the structural adjustment and editing In addition to the functional changes, the main technical changes are as follows:

a) Added a chapter on "Terms and Definitions" (see Chapter 3);

b) Added the classification of combustible gas alarm controllers according to the use environment and application mode (see

c) Added enclosure protection requirements (see 5.3.1.6);

d) Added the shell combustion performance requirements (see 5.3.1.7);

e) Changed the record storage function requirements (see 5.3.1.9,

4.1.3.10 of the.2008 edition);

f) Added wiring requirements for audio components (see 5.3.4.1);

g) Added backup power supply and battery requirements (see 5.3.7);

h) Changed the display requirements for delay time (see 5.5.1.3,

4.1.3.3 of the.2008 edition);

i) Added the function that the controller can only send out a combustible gas alarm signal after receiving two or more combustible gas alarm signals Requirements (see 5.5.1.8);

j) Added the requirements for combustible gas alarm control functions (see 5.5.2);

1 Scope

China's mandatory national standard for combustible gas alarm control units. The control unit is the panel that gathers the signals from gas detectors and decides what to do: raise the alarm, close a valve, start ventilation, shut down a plant. Because it is the point where detection becomes action, its failure modes matter more than a detector's. A unit that fails silently leaves a plant unprotected while everyone believes it is monitored, so the standard requires that faults - a broken cable, a failed detector, a lost supply - be detected and signalled as faults rather than ignored, and distinguished from a gas alarm so that the response is right. Around that sit the two alarm thresholds, typically at a fifth and two fifths of the lower explosive limit, the response and reset behaviour, the battery endurance, and the electromagnetic compatibility of equipment that lives in an industrial environment.

This document defines the terminology of combustible gas alarm controllers, specifies the classification, technical requirements, inspection rules and markings, and describes the corresponding Test method. This document applies to the design, manufacture, and maintenance of combustible gas alarm controllers (hereinafter referred to as "controllers") used in industrial and civil buildings. Make and test.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document.

GB/T 4208-2017 Degrees of protection provided by enclosures (IP code)

GB 4717-2024 Fire Alarm Controller

GB/T 9969 General Principles for Instructions for Use of Industrial Products

GB 12978 Inspection Rules for Fire Protection Electronic Products

GB/T 16838 Environmental test methods and severity levels for fire protection electronic products

GB/T 17626.2 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test

GB/T 17626.3 Electromagnetic compatibility test and measurement techniques Part

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Shield status disabled condition The state the controller is in after the muting function is activated.

3.2 Self-test condition The state of the controller when performing self-test function.

3.3 Normal monitoring status monitoringcondition The state of the controller when it is powered on and operating normally, and no combustible gas alarm, fault alarm, shielding, self-test, etc. occurs.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

How to Buy GB 16808-2025

  1. 1Add to cart. Click the "Buy GB 16808-2025" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 16808-2025

$485.00

$410.00for partners