Valid

GB/T 9265-2009Determination for alkali resistance of film of - Architectural paints and coatings (English PDF)

建筑涂料 涂层耐碱性的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 9265-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 2, 2009

Implementation date

February 1, 2010

Scope

GB/T 9265-2009 is the English-translated version of 建筑涂料 涂层耐碱性的测定.

GB/T 9265-2009 is the Chinese national method for determining the alkali resistance of films of architectural paints and coatings, using a saturated calcium hydroxide solution.

It covers sampling, the test panel, the procedure, the inspection of the panels and the test report.

The substrate is a non-asbestos fibre cement flat sheet of NAF H grade V to JC/T 412.1-2006, prepared according to GB/T 9271; the test runs at a temperature of (23 ± 2) °C and a relative humidity of (50 ± 5) %, on three panels whose edges and backs are sealed with a paraffin and rosin mixture 2 mm to 4 mm wide.

Panels are then rinsed, blotted and examined at once for discoloration, bubbles, stripping, pulverization and softening. It replaces GB/T 9265-1988, was issued on 2 June 2009 and has applied since 1 February 2010.

Found what you need?

Document preview — GB/T 9265-2009

National Standard of the People's Republic of China

ICS
87.040
Classification
G 50
Replacing
GB/T 9265-1988

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative References4
  • 3 Sampling4
  • 4 Test Panel5
  • 5 Procedures5
  • 6 Inspection and Result Determination of Test Panel6
  • 7 Test Report6

Foreword

This Standard serves as a replacement of GB/T 9265-1988 Determination for Alkali Resistance of Film of Architectural Paints and Coatings.

In comparison with the previous GB/T 9265-1988, there are the following main technical changes.

---The substrate of test panel is modified from asbestos cement board into non-asbestos fiber cement flat sheet;

---In the result of determination, a stipulation that when pathological phenomena (bubbles, stripping and pulverization, etc.) of coating emerge, it can be determined in accordance with GB/T 1766 is added.

1 Scope

This Standard specifies the method of determining alkali resistance (saturated calcium hydroxide solution) of film of architectural paints and coatings.

2 Normative References

Through the quotation in this Standard, the provisions in the following documents become provisions of this Standard. In terms of references with a specified date, all the subsequent modifications (excluding the corrected content) or modified versions are not applicable to this Standard. However, all parties that reach an agreement in accordance with this Standard are encouraged to explore the possibility of adopting the latest version of these documents. The latest version of references without a specified date is applicable to this Standard.

GB/T 1766 Paints and Varnishes - Rating Schemes of Degradation of Coats

GB/T 3186 Paints, Varnishes and Raw Materials for Paints and Varnishes - Sampling (GB/T 3186-2006, ISO 15528:2000, IDT)

GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods (GB/T 6682-2008, ISO 3696:1987, MOD)

GB/T 9271 Paints and Varnishes - Standard Panels for Testing (GB/T 9271-2008, ISO 1514:2004, MOD)

3 Sampling

In accordance with the stipulation in GB/T 3186, take representative samples from products being tested (or each type of products in a multi-coating system).

4 Test Panel

4.1 Materials and Dimensions

Unless it is otherwise stipulated, the substrate of the test panel shall be non-asbestos fiber cement flat sheet that complies with NAF H Grade-V in JC/T 412.1-2006. In addition, it shall be flat and not distorted.

4.2 Processing and Preparation

Unless it is otherwise stipulated, test panel shall be processed in accordance with GB/T 9271; then, products being tested shall be coated in accordance with the stipulated method. Any difference from the requirement in GB/T 9271 shall be indicated in the test report (refer to Chapter 7).

5 Procedures

5.1 Environmental Conditions

Unless it is otherwise stipulated, the test shall be conducted under the condition of temperature (23 ± 2) °C and relative humidity (50 ± 5) %.

5.3 Test Procedures

Take 3 previously prepared test panels; use the mixture of paraffin and rosin (mass ratio. 1.1) to seal up the edges and the back of the test panels. The width of the edge sealing shall be 2 mm ~ 4 mm.

6 Inspection and Result Determination of Test Panel

After soaking is completed, take out the test panels, then, use water to rinse it. Get rid of water drops on the panels, the, use filter paper to absorb the water. Immediately observe whether the surface of the coating manifests discoloration, bubbles, stripping, pulverization and softening, etc.

7 Test Report

Test report shall at least include the following content. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Cited by

Similar standards

Editions of GB/T 9265

EditionTitleRevisionStatus
GB/T 9265-2009Determination for alkali resistance of film of - Architectural paints and coatingscurrent editionCurrent
GB/T 9265-1988Determination for alkali resistance of film of - Architectural paints and coatingsprevious editionSuperseded

This page sells the current edition, GB/T 9265-2009. Earlier editions are listed for reference only.

How to Download GB/T 9265-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 9265-2009

$75.00