Valid

GB/T 38836-2020Technical specification for construction of rural household latrine with three-compartment septic tank (English PDF)

农村三格式户厕建设技术规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 38836-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

April 28, 2020

Implementation date

April 28, 2020

Scope

GB/T 38836-2020 is the English-translated version of 农村三格式户厕建设技术规范.

GB/T 38836-2020 is the Chinese standard "Technical specification for construction of rural household latrine with three-compartment septic tank".

Its scope clause reads: This standard stipulates the basic requirements, design requirements, installation and construction requirements, and engineering quality acceptance requirements for the construction of rural three-format household toilets.

This standard applies to the construction or reconstruction of rural three-format household toilets. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 38836-2020

National Standard of the People's Republic of China

ICS
91.040.99
Classification
P 53

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Basic requirements
  • 5 Design requirements
  • 5.1 General requirements
  • 5.2 Site selection
  • 5.3 Toilet House
  • 5.4 Sanitary ware
  • 5.5 Three-cell septic tank
  • 6 Installation and construction requirements
  • 6.1 General requirements
  • 6.2 On-site inspection of materials and equipment
  • 6.3 Construction of toilet houses
  • 6.4 Installation of sanitary ware
  • 6.5 Installation and construction of integral three-cell septic tank
  • 6.6 Construction of the existing three-cell septic tank
  • 7 Engineering quality acceptance requirements
  • 7.1 General requirements
  • 7.2 Acceptance requirements
  • Appendix A (informative appendix) Schematic diagram of rural three-format household toilet construction
  • Appendix B (Normative Appendix) Sealed Full Water Test and Effective Volume Test

1 Scope

This standard stipulates the basic requirements, design requirements, installation and construction requirements, and engineering quality acceptance requirements for the construction of rural three-format household toilets.

This standard applies to the construction or reconstruction of rural three-format household toilets.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article

Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.

GB/T 6952 Sanitary ceramics

GB/T 14152 Thermoplastics pipe external impact resistance test method hour hand rotation method

GB 19379 Sanitary Code for Rural Household Toilets

GB 50268 Code for Construction and Acceptance of Water Supply and Drainage Pipeline Engineering

Technical requirements of CJ/T 409 glass steel septic tank

CJ/T 489 plastic septic tank

JC/T 2116 Non-ceramic sanitary ware

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Three-compartment septic tank

It is composed of three pools connected in series, and through the process of fecal sedimentation and anaerobic digestion in a closed environment, the parasite eggs are removed and killed, etc.

Pathogen, harmless treatment and storage facility or equipment for controlling the breeding of mosquitoes and flies.

Note. The three-slot septic tank includes integral type and existing type. Use plastic or glass fiber reinforced plastics and other materials to produce three-layer septic tank products in the factory as a whole;

The three-slot septic tank constructed on-site by means of brickwork, cast-in-place concrete or concrete prefabricated parts is currently built.

3.2 Rural three-format household toilet

It is composed of toilet houses, sanitary ware, three-slot septic tanks, etc., and is used by rural households who use three-slot septic tanks to harmlessly treat toilet feces.

WC.

Note. The toilet house is divided into an attached building and a stand-alone. Those built in residential houses or integrated with the main living houses are of additional construction type; those built outside residential houses and other living houses are

Detached.

3.3 Nightsoilsewage

A mixture of feces and urine excreted by the human body and its flushing sewage.

3.4 Three-frame septic tank effective volume available volume of

The volume of the three-slot septic tank from the bottom of the overflow port of the septic pipe to the bottom of the tank.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 38836-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 38836-2020

$225.00