GB/T 36567-2018Code of maintenance for photovoltaic module (English PDF)
光伏组件检修规程
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36567-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 17, 2018
Implementation date
April 1, 2019
Scope
GB/T 36567-2018 is the English-translated version of 光伏组件检修规程.
GB/T 36567-2018 sets out how photovoltaic modules are maintained in service. It covers the principles, content, methods and tests of module overhaul, starting from the basic requirements and moving through the maintenance items, methods and cycles, the replacement, repair and recycling of modules, and the tests to be carried out on them.
Its definitions distinguish scheduled maintenance, corrective maintenance after a failure and condition-based maintenance, and describe defects such as hot spots and micro-cracks in the cells.
Annexes give model maintenance and test records and a method for repairing potential-induced degradation (PID). It applies to the maintenance of crystalline silicon and amorphous thin-film modules in photovoltaic power generation systems. It was issued on 17 September 2018 and has applied since 1 April 2019.
Found what you need?
Document preview — GB/T 36567-2018
National Standard of the People's Republic of China
- ICS
- 27.160
- Classification
- F 12
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Basic requirements
- 5 Maintenance items, methods and cycle
- 6 Replacement, repair and recycling
- 7 test
- Appendix A (informative) Photovoltaic module maintenance records and test records
- Appendix B (informative) Potential-induced attenuation (PID) repair of photovoltaic modules
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the principles, contents, methods and tests for PV module overhaul.
This standard applies to the maintenance of crystalline silicon and amorphous film components in photovoltaic power generation systems.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 6495.1 Photovoltaic devices - Part 1. Measurement of photovoltaic current-voltage characteristics
Field measurement of GB/T 18210 crystalline silicon photovoltaic (PV) square array IV characteristics
GB 26860 Electrical safety work procedures Power plant and substation electrical part
GB/T 35694 Photovoltaic Power Station Safety Regulations
GB 50794 photovoltaic power station construction specification
GB 50797 Photovoltaic Power Plant Design Specification
NB/T 32034 Photovoltaic power station field component testing procedures
3 Terms and definitions
The following terms and definitions defined in GB 50797 apply to this document.
3.1 Scheduled maintenance
According to the statistical rules of equipment wear and aging, plan maintenance of maintenance intervals, maintenance items, spare parts and materials required, etc. the way.
3.2 Corrective maintenance
Unplanned maintenance methods for inspection, isolation, and repair of equipment in the event of failure or other failure.
3.3 Condition-based maintenance
The status of the equipment is evaluated based on the equipment status information provided by the condition monitoring and diagnostic technology, and the pre-aware maintenance method before the failure occurs.
3.4 Module hot spot
Some of the cells in the PV module are partially shadowed due to their own reasons or blocked by other objects around them, and some of the blocked cells are produced. The phenomenon of overheating.
3.5 Module hidden crack
When the battery sheet is subjected to large mechanical force or thermal stress, an invisible crack that is invisible to the naked eye is generated in the battery unit.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6495.1Photovoltaic devices - Part 1: Measurement of photovoltaic current-voltage characteristics
- GB/T 18210Photovoltaic array - On-site measurement of current-voltage characteristics
- GB 26860Safety code of electric power industry - Electric part of power plants and transformer substations
- GB/T 35694Safety code for photovoltaic power stations
- GB 50794Code for construction of PV power station
- GB 50797Code for design of photovoltaic power station
Similar standards
How to Download GB/T 36567-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 26860-2011 — Safety code of electric power industry - Electric part of power plants and transformer substations
GB 50794-2012 — Code for construction of PV power station
GB 50797-2012 — Code for design of photovoltaic power station
Secure payment via Stripe
Payments accepted
GB/T 36567-2018
$145.00