GB/T 30844.3-2017Variable-frequency drive of 1kV and below—Part 3: Safety requiements (English PDF)
1kV及以下通用变频调速设备 第3部分:安全规程
This is a limited preview
Buy now to download the full PDF (63 pages)
Need quotation for your management?
Get a formal quotation for GB/T 30844.3-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 7, 2017
Implementation date
April 1, 2018
Scope
GB/T 30844.3-2017 is the English-translated version of 1kV及以下通用变频调速设备 第3部分:安全规程.
GB/T 30844.3-2017 is the Chinese standard "Variable-frequency drive of 1kV and below—Part 3: Safety requiements". Its scope clause reads: GB/T 30844 provisions of this part of the general frequency control equipment or its components on the electrical, thermal and energy other than the power supply Security requirements.
This section does not cover used for traction and electric vehicle frequency control equipment, motors and so on.
This section applies to the rated input voltage of 1kV AC and below the rated input frequency of 50Hz or 60Hz, the output voltage Not more than 1kV, the output frequency is less than 600Hz general frequency control equipment (hereinafter referred to as frequency control equipment).
Note. The exchange of rated voltage 1140V frequency control equipment can refer to this section implementation. The relevant performance requirements are determined by the manufacturer and the user.
Found what you need?
Document preview — GB/T 30844.3-2017
National Standard of the People's Republic of China
- ICS
- 29.240.99
- Classification
- K 46
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword V.
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Design and manufacture of safety requirements
- 4.1 General requirements
- 4.2 dangerous state of protection under fault
- 4.3 Protection against electric shock hazard
- 4.3.1 Define the voltage level
- 4.3.2 Protection Isolation
- 4.3.3 direct contact protection
- 4.3.4 Protection in case of direct contact
- 4.3.5 Indirect contact protection
- 4.3.6 Insulation
- 4.3.7 output short circuit requirements
- 4.3.8 Residual Current Protection (RCD) or Residual Current Monitoring (RCM) Compatibility
- 4.3.9 Capacitor discharge
- 4.4 Thermal Hazard Protection
- 4.4.1 Minimize the risk of fire
- 4.4.2 Insulation material
- 4.4.3 flammability of shell material
- 4.4.4 Temperature Limit
- 4.4.5 Special Requirements for Liquid Cooling VFDs
- 4.5 Mechanical Danger Protection
- 4.5.1 Mechanical Energy Danger
- 4.5.2 Shell Requirements
- 4.5.3 Mechanical Components Requirements
- 4.5.4 Mechanical strength requirements
- 4.5.5 Mechanical Stability
- 4.6 Operational Hazard Protection
- 4.6.1 Hazardous Movement of Moving Parts
- 4.6.2 Noise emission
- 4.6.3 Vibration and anti-vibration
- 4.7 Other dangerous protection
- 4.7.1 Power Danger
- 4.7.2 Electrical connection requirements
- 4.7.3 Power Supply Failure
- 4.7.4 Protection of Environmental Stress
- 4.8 Security Features
- 4.8.1 General requirements
- 4.8.2 Safely stop
- 4.8.3 Overcurrent protection
- 4.8.4 Frequency hopping setting
- 5 test and verification
- 5.1 General requirements
- 5.1.1 Test Purposes and Classification
- 5.1.2 Selection of test samples
- 5.1.3 Test sequence
- 5.1.4 Ground conditions
- 5.1.5 Compliance
- 5.1.6 Summary of pilot projects
- 5.2 Test Technical Requirements
- 5.2.1 appearance inspection
- 5.2.2 Mechanical test
- 5.2.3 Electrical test
- 5.2.4 Non-normal working test
- 5.2.5 Material Test
- 5.2.6 Environmental Test (Type Test)
- 5.2.7 Hydrostatic pressure
- 6 Information and logo requirements
- 6.1 General requirements
- 6.2 Selection Information
- 6.3 Installation and Site Commissioning Information
- 6.3.1 General requirements
- 6.3.2 Appearance and installation diagram
- 6.3.3 Environmental Requirements
- 6.3.4 Handling and Installation
- 6.3.5 Wiring
- 6.3.6 Overcurrent or short circuit protection
- 6.3.7 Motor overload protection
- 6.3.8 Site Commissioning
- 6.4 Usage Information
- 6.4.1 General requirements
- 6.4.2 Parameter Adjustment
- 6.4.3 Identification, Symbols and Signals
- 6.5 Maintenance Information
- 6.5.1 General requirements
- 6.5.2 Capacitor discharge
- 6.5.3 Automatic restart/bypass connection
- 6.5.4 PT/CT Connection
- 6.5.5 Other dangers
- Appendix A (Informative) Clearance for Altitude
- Appendix B (Informative) Symbols used in this section
- Appendix C (Normative) Determination of clearances and creepage distances at frequencies above 30 kHz
- Appendix D (Informative) Circular conductor cross-section
- Appendix E (informative) Example of protection in direct contact
1 Scope
GB/T 30844 provisions of this part of the general frequency control equipment or its components on the electrical, thermal and energy other than the power supply
Security requirements. This section does not cover used for traction and electric vehicle frequency control equipment, motors and so on.
This section applies to the rated input voltage of 1kV AC and below the rated input frequency of 50Hz or 60Hz, the output voltage
Not more than 1kV, the output frequency is less than 600Hz general frequency control equipment (hereinafter referred to as frequency control equipment).
Note. The exchange of rated voltage 1140V frequency control equipment can refer to this section implementation. The relevant performance requirements are determined by the manufacturer and the user.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 311.1-2012 Insulating coordination Part 1. Definitions, principles and rules
GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. High temperature
GB/T 2423.3-2006 Environmental testing for electric and electronic products Part 2. Test methods Test Cab. Constant hot and humid test
GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
GB 2894-2008 Safety signs and guidelines for their use
GB/T 3048.14-2007 wire and cable electrical performance test methods - Part 14. DC voltage test
GB/T 4207-2012 solid insulation materials, resistance to tracking index and compared to the tracking index method of determination
GB/T 4208-2017 enclosure rating (IP code)
Graphical symbols for electrical diagrams Part 1. General requirements
GB/T 4796-2008 Environmental classification of electric and electronic products Part 1. Environmental parameters and their severity
GB/T 5169.10-2006 Fire hazard testing for electrician and electronic products - Part 10. Basic test methods for glow/hot wire
Hot wire installations and common test methods
GB/T 5169.13-2013 Fire hazard testing for electric and electronic products Part 13. Glow/hot wire basic test methods
Material glow wire ignition temperature (GWIT) test method
GB/T 5169.16-2008 Fire hazard testing for electric and electronic products Part 16. Test flame 50W Horizontal and vertical fire
Flame test method
GB/T 5169.17-2008 Fire hazard testing for electric and electronic products - Part 17. Test flame 500 W flame test method
Graphical symbols for electrical equipment - Part 2. Graphical symbols
GB/T 6829-2008 Residual Current Surge Protector General Requirements
Industrial plug and socket connectors and couplers - Part 1. General requirements GB/T 11918.1-2014
Measuring methods for contact current and protective conductor current GB/T 12113-2003
GB/T 12668.1-2002 speed control electrical transmission system Part 1 General requirements Low-voltage DC speed electrical transmission system amount
The value of the provisions
GB/T 12668.2-2002 speed control electrical transmission system Part 2. General requirements of low-voltage AC variable frequency electrical drive system amount […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 63 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.2-2008Environmental testing for electric and electronic products - Part 2: Test methods - Tests B: Dry heat
- GB/T 2423.3-2006Environmental testing - Part 2: Testing method - Test Cab: Damp heat, steady state
- GB/T 2423.10-2008Environmental testing - Part 2: Test methods - Test Fc: Vibration (sinusoidal)
- GB 2894-2008Safety colours and safety signs
- GB/T 3048.14-2007Test methods for electrical properties of electric cables and wires -- Part 14: DC voltage test
- GB/T 4207-2012Method for the determination of the proof and the comparative tracking indices of solid insulating materials
GB/T 311.1-2012
Similar standards
How to Download GB/T 30844.3-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 11918.1-2014 — Plugs, socket-outlets and couplers for industrial purposes -- Part 1: General requirements
GB/T 12668.1-2002 — Adjustable speed electrical power drive systems -- Part 1: General requirements -- Rating specifications for low voltage adjustable speed d.c. power drive systems
GB/T 12668.2-2002 — Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifications for adjustable speed AC power drive systems
Secure payment via Stripe
Payments accepted
GB/T 30844.3-2017
$830.00