GB/T 29374-2022Grain and oils storage—Code of practice for applicative technology of grain chiller (English PDF)

粮油储藏 谷物冷却机应用技术规程

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 29374-2022 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 30, 2022

Implementation date

July 1, 2023

Scope

GB/T 29374-2022 is the English-translated version of 粮油储藏 谷物冷却机应用技术规程.

GB/T 29374-2022 tells grain depots how to use a grain chiller to keep stored grain cold.

It gives the configuration requirements for the chiller and its operators, and the operating procedures for chilled ventilation: the preparations beforehand, the management while the chiller runs and once it stops, and the conditions for starting and ending a run.

It also covers the low-temperature storage operation record, the relative humidity set at the chiller air outlet, the assessment of unit energy consumption and the unit cost of lowering grain temperature.

It applies to vertical chilled ventilation of room-type, shallow round and vertical silos holding raw grain, oilseeds and non-powdered finished grain, and to horizontal chilled ventilation of room-type warehouses spanning 24 m or less.

It replaces GB/T 29374-2012, was issued on 30 December 2022 and has applied since 1 July 2023.

Found what you need?

Document preview — GB/T 29374-2022

National Standard of the People's Republic of China

ICS
65.040.20
Classification
B 93
Replacing
GB/T 29374-2012

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting.

This document replaces GB/T 29374-2012 "Technical Regulations for the Application of Grain Coolers for Grain and Oil Storage", and GB/T 29374-2012 In comparison, except for structural adjustments and editorial changes, the main technical changes are as follows.

--- Changed the configuration requirements related to the horizontal valley cooling ventilation (see 4.1.1, 4.1.2, 4.1.1, 4.1.2, 4.1.3 of the 2012 edition);

--- Added the requirements for the warehouse when the horizontal valley cooling ventilation is used (see 4.2.2, 4.2.4);

--- Increased operating conditions for horizontal valley cooling ventilation (see 4.3.2.5, 4.3.3.2);

--- Increased valley cold ventilation operating procedures (see Chapter 6);

--- Changed the speed requirement when the grain cooler moves (see 7.1.1.1, 6.1.1.1 of the 2012 edition);

--- Added other preparations related to horizontal valley cooling ventilation (see 7.2.3, 7.2.5, 7.2.6, 7.2.7);

--- Increased the connection requirements of the split grain cooler and the ventilation system (see 7.3.2, 7.3.3, 7.3.5);

--- Changed the cooling ventilation parameters (see 7.4.3, 7.4.4, 6.1.3.3, 6.1.3.4 of the 2012 edition);

--- Added cross ventilation cooling ventilation parameters and other related requirements (see 7.4.5, 7.4.7);

--- Added instructions for operation and management during valley cold ventilation (see 7.5.1.2, 7.5.1.3, 7.5.1.5, 7.5.3.1, 7.5.3.4, 7.5.3.5);

---Changed the grain cooler low-temperature grain storage operation card (see Appendix E, Appendix E of the 2012 edition).

1 Scope

This document specifies the configuration requirements for the application of grain coolers and the requirements for equipment operators, and establishes the operating procedures for grain cooler ventilation.

It stipulates the preparation before the valley cold ventilation, the operation and management during the ventilation period, the management after the ventilation is over, and other operation instructions, as well as the start of the valley cold ventilation. and the end conditions, describe the low-temperature grain storage operation record of the grain cooler, the setting of the air relative humidity at the air outlet of the grain cooler, the grain cold ventilation Corresponding verification methods such as unit energy consumption assessment of wind and unit cost calculation of reducing grain temperature.

This document is applicable to the vertical grain cooling and ventilation of room-type silos, shallow round silos and vertical silos for storing various raw grains, oil crops and non-powder finished grains, and horizontal valley cooling ventilation for room-type warehouses with a span of 24m or less.

2 Normative references

The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 18835 Grain cooler

GB/T 25229 Airtightness requirements for grain and oil storage bungalows

GB/T 26882.1 Grain and Oil Storage Grain Situation Monitoring and Control System Part 1: General Rules

GB/T 29890 Technical Specifications for Grain and Oil Storage

LS/T 1202 Technical Regulations for Mechanical Ventilation of Grain Storage

LS/T 1220 Technical specification for horizontal ventilation of one-storey warehouse

3 Terms and Definitions

The following terms and definitions defined in GB/T 29890 apply to this document.

3.1 Grain cooler grainchiler

It is a special mechanical equipment that can reduce the temperature of the air and input it into the grain pile to reduce the temperature of the grain.

Note: It mainly includes refrigeration system, air supply and purification device, temperature and humidity adjustment device.

3.2 Unit energy consumption of grain cooling ventilation

During the operation of the grain cooler, the average temperature of each ton of grain is reduced by 1°C in electricity consumption.

Note: The unit is kilowatt-hour per ton Celsius [kW·h/(t·°C)].

3.3 Valley cold ventilation

Cooling and ventilating grain piles by using a grain cooler.

Note: Including vertical valley cooling ventilation and horizontal valley cooling ventilation.

3.4 Vertical valley cold ventilation

After the outside air is cooled by the grain cooler, the air with a certain temperature and humidity is obtained, which passes through the grain pile vertically and exchanges heat with the grain pile to achieve

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 29374

EditionTitleRevisionStatus
GB/T 29374-2022Grain and oils storage—Code of practice for applicative technology of grain chillercurrent editionCurrent
GB/T 29374-2012Grain and oils storage—Code of practice for applicative technology of grain chillerprevious editionSuperseded

This page sells the current edition, GB/T 29374-2022. Earlier editions are listed for reference only.

How to Download GB/T 29374-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29374-2022

$240.00