Valid

GB/T 2624.3-2006Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles (English PDF)

用安装在圆形截面管道中的差压装置测量满管流体流量 第3部分:喷嘴和文丘里喷嘴

Preview PDF

Also coversGBT2624.3-2006

This is a limited preview

Buy now to download the full PDF (49 pages)

Need quotation for your management?

Get a formal quotation for GB/T 2624.3-2006 in 30 minutes.

Issued by

AQSIQ; Standardization Administration of China

Level / Type

National · Recommended

Issue date

December 13, 2006

Implementation date

July 1, 2007

Scope

GB/T 2624.3-2006 is the English-translated version of 用安装在圆形截面管道中的差压装置测量满管流体流量 第3部分:喷嘴和文丘里喷嘴.

GB/T 2624.3-2006 is the Chinese standard "Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles".

Its scope clause reads: This part of GB/T 2624 specifies the geometry and method of use (installation and operating conditions) of nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit.

This part of GB/T 2624 also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in GB/T 2624.1.

This part of GB/T 2624 is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase.

In addition, each of the devices can only be used within specified limits of pipe size and Reynolds number. It is not applicable to the measurement of pulsating flow.

It does not cover the use of nozzles and Venturi nozzles in pipe sizes less than 50 mm or more than 630 mm, or where the pipe Reynolds numbers are below 10 000.

This part of GB/T 2624 deals with a) two types of standard nozzles: 1) the ISA 1932 nozzle; 2) the long radius nozzle5); b) the Venturi nozzle. The two types of standard nozzle are fundamentally different and are described separately in this part.

The Venturi nozzle has the same upstream face as the ISA 1932 nozzle, but has a divergent section and, therefore, a different location for the downstream pressure tappings, and is described separately.

Found what you need?

Document preview — GB/T 2624.3-2006

National Standard of the People's Republic of China

ICS
17.120.10
Classification
N 12
Replacing
GB/T 2624-1993

Issued by: AQSIQ; Standardization Administration of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principles of the method of measurement and computation
  • 5 Nozzles and Venturi nozzles
  • 6 Installation requirements
  • Annex A (informative) Tables of discharge coefficients and expansibility [expansion] factors
  • Bibliography

1 Scope

This part of GB/T 2624 specifies the geometry and method of use (installation and operating conditions) of nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit.

This part of GB/T 2624 also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in GB/T 2624.1.

This part of GB/T 2624 is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. In addition, each of the devices can only be used within specified limits of pipe size and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of nozzles and Venturi nozzles in pipe sizes less than 50 mm or more than 630 mm, or where the pipe Reynolds numbers are below 10 000.

This part of GB/T 2624 deals with

a) two types of standard nozzles:

1) the ISA 1932 nozzle;

2) the long radius nozzle5);

b) the Venturi nozzle.

The two types of standard nozzle are fundamentally different and are described separately in this part. The Venturi nozzle has the same upstream face as the ISA 1932 nozzle, but has a divergent section and, therefore, a different location for the downstream pressure tappings, and is described separately.

2 Normative references

The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 2624. For dated references, subsequent amendments […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 49 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 2624.3-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
49 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 2624.3-2006

$245.00