GB/T 26801-2011Fluid flow in closed conduits -- Connections for pressure signal transmissions between primary and secondary elements (English PDF)
封闭管道中流体流量的测量 一次装置和二次装置之间压力信号传送的连接法
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for GB/T 26801-2011 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
July 29, 2011
Implementation date
December 1, 2011
Scope
GB/T 26801-2011 is the English-translated version of 封闭管道中流体流量的测量 一次装置和二次装置之间压力信号传送的连接法.
GB/T 26801-2011 — This standard specifies the means between the primary and the secondary device pressure signal transmission system design, layout and installation.
By pressure signal transmission Delivery system, using known techniques of fluid flow measuring a pressure signal from the device safely transferred to a secondary device, and the signal will not Distorted or changed.
Found what you need?
Document preview — GB/T 26801-2011
National Standard of the People's Republic of China
- ICS
- 17.120.10
- Classification
- N 12
Issued by: Standardization Administration of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 1 General
- 4.1 Safety seal
- 4.2 Pipe size
- 4.3 Isolation valve (valve)
- 4.4 Manifold
- 4.5 Installation
- 4.6 Taps
- Size 4.7 Impulse tube
- 4.8 Insulation
- 5 5 horizontal pipe installation
- 5.1 Gas
- 5.2 Liquid
- 5.3 Condensed steam, such as water vapor
- 6 Vertical pipe installation
- 6.1 General
- 6.2 Gas
- 6.3 Liquid
- 6.4 Condensed steam, such as steam
- 7 Grading ring
- 8 7 special case
- Appendix A (informative) long connecting pipe diameter 8 Select Guide
- Annex B (informative) Impulse control of dynamic characteristics
- Annex C (informative) head height calculation example
- Annex D (informative) Supplementary legend
- References
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with ISO 2186:2007 "Measurement of fluid flow in closed conduits primary device and the secondary device Pressure between the transmitted signal connection method. " this standard made the following editorial changes.
a) a reference to the original standard 5.1 and 5.2, the slope of the "8%" into a unified representation of the original reference standard Figure D.3, namely "1.12.5";
b) by deleting references to the original standard table A.1 title in parentheses, brackets put the contents of a table showing the top right of the unit taken, and deleted
Table A.1 "pressure signal is transmitted from the" bottom "mm" error representation;
c) a reference to the original standard table C.1, the values \u200b\u200blisted in the table by the lack of specific volume density values \u200b\u200bshown in the table, this is due to the specific volume given Value due to insufficient number of significant digits. Contrast this standard capacitance values \u200b\u200bdid Correction. In 0.001001969m3/kg instead of 0.001002m3/kg; in 0.001004466m3/kg instead of 0.001004m3/kg.
The standard proposed by China Machinery Industry Federation.
This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized.
This standard was drafted. Shanghai Industrial Automation Instrument Research Institute, Shanghai Automation Instrumentation System Inspection and Testing Institute, Yuyao silver circulation Instrument Co., Ltd., Naval Aviation devices metering station.
1 Scope
This standard specifies the means between the primary and the secondary device pressure signal transmission system design, layout and installation. By pressure signal transmission Delivery system, using known techniques of fluid flow measuring a pressure signal from the device safely transferred to a secondary device, and the signal will not Distorted or changed.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2624.1-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 1. General Principles and requirements (ISO 5167-1:2003, IDT) GB/T 2624.2-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 2. Orifice (ISO 5167-2:2003, IDT) GB/T 2624.3-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 3. Nozzle Venturi nozzles (ISO 5167-3:2003, IDT) GB/T 2624.4-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 4. Venturi Tubes (ISO 5167-4:2003, IDT) GB/T 17611 in closed conduits measuring fluid flow terms and symbols (GB/T 17611-1998, ISO 4006:1991, IDT)
3 Terms and Definitions
GB/T 17611 and GB/T 2624.1 and define the following terms and definitions apply to this document.
Secondary means secondarydevice Receiving a pressure signal from the device, and can display the differential pressure signal into a different form, such as a digital signal or an analog signal Number, and then transferred to the differential pressure device according to another place.
4 General
4.1 Safety seal
Differential pressure signal to be transmitted through a pipe or hose securely to the secondary device. This requires a secure seal between the primary and the secondary device means Fluid. Safety sealing fluid required to meet the applicable standards and regulations, the need to use a suitable structural materials, production methods, washers and password
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2624.1-2006 · ISO 5167 · GB/T 2624.2-2006 · GB/T 2624.3-2006 · GB/T 2624.4-2006 · GB/T 17611 · GB/T 17611-1998 · ISO 4006
How to Download GB/T 26801-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 7463-2026 — Surface active agents - Determination of the power to disperse calcium soap - Acidimetric method (Modifled Schoenfeldt method)
GB/T 8336-2026 — Special threads gauges for gas cylinders
GB/T 48115-2026 — Technical requirements for GNSS radio occultation detection payload
Secure payment via Stripe
Payments accepted
GB/T 26801-2011
$195.00