GB/Z 33902-2017Measurement of fluid flow by means of pressure differential devices -- Guidelines on the effect of departure from the specifications and operating conditions given in GB/T 2624 and the correction methods (English PDF)
Also coversGBZ33902-2017
Open the GB/Z 33902-2017 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
July 12, 2017
Implementation date
February 1, 2018
Scope
GB/Z 33902-2017 (Measurement of fluid flow by means of pressure differential devices -- Guidelines on the effect of departure from the specifications and operating conditions given in GB/T 2624 and the correction methods) is available as an English-translated PDF.
GB/Z 33902-2017 — This guidance is given in the guidance of technical documents using the structure and working conditions beyond the scope of GB/T 2624 differential pressure device to measure flow guide. Additional tolerances or amendments do not necessarily compensate deviations from the provisions of GB/T 2624 (all parts) of the impact. This guideline technique The information given in the document first describes the effects that will be caused by the non-conformity of the requirements to specify the necessary requirements for the manufacture, installation and maintenance of DP devices The second is to enable users who can not fully meet the requirements to generally estimate the size and scope of the resulting traffic error. Each of the changes described in this guidance document is considered the only change that has occurred. If it is known that there are multiple changes, it may be saved In unpredictable interactions, special attention needs to be paid when evaluating these errors in combination. If there is a considerable amount of error, it must be Consider ways to eliminate some of these errors. The changes included in this guidance document are not exhaustive and relate mainly to the fact that the orifice example. An example of a venturi is given at the end of the chapter. There is no doubt that the device does not meet GB/T 2624 (all parts) There are many similar examples, no disclosure of any comparable data. Such additional letters are obtained from users, manufacturers or other sources Interest rates may be considered in the next version of this guidance document.
Document preview — GB/Z 33902-2017
National Standard of the People's Republic of China
- ICS
- 17.120.10
- Classification
- N 12
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
Foreword
This instructional document has been drafted in accordance with the rules given in GB/T 1.1-2009.
This Guidance Document is equivalent to translation method ISO /T R12767.2007 "Measurement of Fluid Flow Deviation Using Differential Pressure Devices
ISO 5167 given the requirements and working conditions impact guide. "
The following editorial changes have been made to this technical document.
--- Change the name of the document to "Use differential pressure devices to measure fluid flow deviations from the requirements and working conditions given in GB/T 2624
Ring and its correction method. "
This guidance document corrects editorial errors in ISO /T R12767-2007.
--- Figure 2 is not drawn in the curve, the document to draw a curve;
--- 6.4.4 Last line, add "%" after 0.5 and 0.078;
--- formula (4) deltaqm and deltaD to deltaqm, deltaD;
--- Figure 7 of beta to delta.
This guidance document is proposed by China Machinery Industry Federation.
This Guidance Document is governed by the National Technical Committee for Measurement, Control and Automation of Industrial Processes (SAC/TC124).
The guiding technical document is drafted by Shanghai Institute of Industrial Automation Instrumentation.
The guidance of technical documents to participate in the drafting unit. Beijing Ruipu ternary Instrument Co., Ltd., Fujian Run Precision Instrument Co., Ltd., Jiangsu
Provincial Quality and Technical Supervision gas flow measurement and testing center, Jiangyin throttling Plant Co., Ltd., Shanghai Weier Tai Industrial Automation Co., Ltd.
Division, Shenyang North Star Instrument Manufacturing Co., Ltd., Tianxin Instrument Group Co., Ltd., Tianjin Xinke Complete Instrument Co., Ltd. Zhejiang Cangnan instrument set
Group Co., Ltd.
Introduction
GB/T 2624 (all parts) provides for the use of differential pressure device to measure the flow method. Observe the provisions of GB/T 2624 (all parts)
The uncertainty of the flow measurement can be within a limited range. However, if the flow measurement device, for whatever reason, deviates
GB/T 2624 (all parts) under the conditions specified may not be able to achieve the required uncertainty. Many measuring devices are not present or not
Law consistent with these conditions. In such cases, it is often not possible to accurately assess the effects of deviations. However, there is a lot of data available
To illustrate the impact does not meet GB/T 2624 (all parts), the contents of this document as a guide to the flow measurement device
user.
Use differential pressure to measure fluid flow
Deviate from the requirements given in GB/T 2624 and
Influence of Working Conditions and Correction Methods
1 Scope
This guidance is given in the guidance of technical documents using the structure and working conditions beyond the scope of GB/T 2624 differential pressure device to measure flow guide.
Additional tolerances or amendments do not necessarily compensate deviations from the provisions of GB/T 2624 (all parts) of the impact. This guideline technique
The information given in the document first describes the effects that will be caused by the non-conformity of the requirements to specify the necessary requirements for the manufacture, installation and maintenance of DP devices
The second is to enable users who can not fully meet the requirements to generally estimate the size and scope of the resulting traffic error.
Each of the changes described in this guidance document is considered the only change that has occurred. If it is known that there are multiple changes, it may be saved
In unpredictable interactions, special attention needs to be paid when evaluating these errors in combination. If there is a considerable amount of error, it must be
Consider ways to eliminate some of these errors. The changes included in this guidance document are not exhaustive and relate mainly to the fact that the orifice
example. An example of a venturi is given at the end of the chapter. There is no doubt that the device does not meet GB/T 2624 (all parts)
There are many similar examples, no disclosure of any comparable data. Such additional letters are obtained from users, manufacturers or other sources
Interest rates may be considered in the next version of this guidance document.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2624.1-2006 Measurement of full pipe fluid flow using differential pressure devices installed in circular sectioned pipes - Part 1. General
Principles and requirements (ISO 5167-1.2003, IDT)
GB/T 2624.2-2006 Measurement of full pipe fluid flow using a differential pressure device installed in a circular sectioned pipe - Part 2 - Orifice
(ISO 5167-2.2003, IDT)
GB/T 2624.3-2006 Manifold fluid flow measurement using a differential pressure device mounted in a circular sectioned pipe - Part 3. Nozzle
And Venturi nozzle (ISO 5167-3.2003, IDT)
GB/T 2624.4-2006 Manifold fluid flow measurement using differential pressure devices installed in circular sectioned pipes - Part 4 Ventura
In tube (ISO 5167-4.2003, IDT)
3 Terms and definitions
GB/T 2624.1-2006 defined and the following terms and definitions apply to this document.
3.1
Square edge
The angular relationship between the orifice of the flow measurement device and the upstream end face is 90 ° +/- 0.3 °.
3.2
Sharpness sharpness
The radius of the edge between the orifice of the flow measurement device and the upstream face.
Note. When the edge radius is not more than 0.0004d, the upstream edge of the orifice can be considered as a sharp edge, and d means the orifice diameter.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2624.1-2006 · ISO 5167 · GB/T 2624.2-2006 · GB/T 2624.3-2006 · GB/T 2624.4-2006
How to Buy GB/Z 33902-2017
- 1Add to cart. Click the "Buy GB/Z 33902-2017" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 120.305-2026 — Microgrids - Part 3-5: Testing for microgrid monitoring, control, and energy management systems
GB/Z 121-2026 — Evaluation index system for sustainable rural development
GB/Z 128-2026 — Course development guide for education about standardization - Fundamentals of quality management
Secure payment via Stripe
Payments accepted
GB/Z 33902-2017
$540.00